Cargando…
The accuracy of cortical bone trajectory screw placement guided by spinous process clamp hardware in lumbar spinal surgery: a retrospective study
This study aimed to assess the accuracy of cortical bone trajectory (CBT) screws placement guided by a spinous process clamp (SPC) guide. A total of 32 patients who received single-level midline lumbar fusion (MIDLF) surgery between June 2019 and January 2020 were retrospectively analyzed and divide...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10542810/ https://www.ncbi.nlm.nih.gov/pubmed/37777594 http://dx.doi.org/10.1038/s41598-023-43406-1 |
_version_ | 1785114172970762240 |
---|---|
author | Zhang, Xi-nuo Su, Qing-jun Pei, Bao-qing Pan, Ai-xing Yang, Hong-hao Ding, Hong-tao Hai, Yong Liu, Yu-zeng |
author_facet | Zhang, Xi-nuo Su, Qing-jun Pei, Bao-qing Pan, Ai-xing Yang, Hong-hao Ding, Hong-tao Hai, Yong Liu, Yu-zeng |
author_sort | Zhang, Xi-nuo |
collection | PubMed |
description | This study aimed to assess the accuracy of cortical bone trajectory (CBT) screws placement guided by a spinous process clamp (SPC) guide. A total of 32 patients who received single-level midline lumbar fusion (MIDLF) surgery between June 2019 and January 2020 were retrospectively analyzed and divided into free-hand (FH) and SPC-guided groups according to the surgical approach. In the FH group, CBT screws was implanted with the assistance of fluoroscopy, while in the SPC group, CBT screws was implanted using the SPC navigator hardwire. A total of 128 screws were assessed in this study, with higher rates of clinically acceptable screw placement (grades A and B) and grade A screws in the SPC group than in the FH guide group (92.2% vs. 79.7%, P = 0.042 and 54.7% vs. 35.9%, P = 0.033, respectively). Misplacement screws (grades C, D, and E) occurred more often in the FH group than in the SPC guide group (20.3% vs. 7.8%, P = 0.042). The incidence of proximal facet joint violation (FJV) was higher in the FH group than in the SPC group (15.6% vs. 3.1%, P = 0.030). The radiation dose and time in the SPC guide group were comparable to those in the FH group (P = 0.063 and P = 0.078). The average operative time was significantly longer in the SPC guide group than in the FH group (267.8 ± 45.5 min vs. 210.9 ± 44.5 min, P = 0.001). Other clinical parameters, such as the average bone mineral density (BMD), intraoperative blood loss, and postoperative hospital stay, were not significantly different. Oswestry disability index (ODI) and back pain visual analogue scale (VAS) scores were significantly improved in both groups compared with preoperatively. SPC guided screw placement was more accurate than the fluoroscopy-assisted FH technique for single-level MIDLF at L4/5. Patients undergoing SPC-guided screw placement can achieve similar clinical outcomes as the fluoroscopy-assisted FH technique. |
format | Online Article Text |
id | pubmed-10542810 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-105428102023-10-03 The accuracy of cortical bone trajectory screw placement guided by spinous process clamp hardware in lumbar spinal surgery: a retrospective study Zhang, Xi-nuo Su, Qing-jun Pei, Bao-qing Pan, Ai-xing Yang, Hong-hao Ding, Hong-tao Hai, Yong Liu, Yu-zeng Sci Rep Article This study aimed to assess the accuracy of cortical bone trajectory (CBT) screws placement guided by a spinous process clamp (SPC) guide. A total of 32 patients who received single-level midline lumbar fusion (MIDLF) surgery between June 2019 and January 2020 were retrospectively analyzed and divided into free-hand (FH) and SPC-guided groups according to the surgical approach. In the FH group, CBT screws was implanted with the assistance of fluoroscopy, while in the SPC group, CBT screws was implanted using the SPC navigator hardwire. A total of 128 screws were assessed in this study, with higher rates of clinically acceptable screw placement (grades A and B) and grade A screws in the SPC group than in the FH guide group (92.2% vs. 79.7%, P = 0.042 and 54.7% vs. 35.9%, P = 0.033, respectively). Misplacement screws (grades C, D, and E) occurred more often in the FH group than in the SPC guide group (20.3% vs. 7.8%, P = 0.042). The incidence of proximal facet joint violation (FJV) was higher in the FH group than in the SPC group (15.6% vs. 3.1%, P = 0.030). The radiation dose and time in the SPC guide group were comparable to those in the FH group (P = 0.063 and P = 0.078). The average operative time was significantly longer in the SPC guide group than in the FH group (267.8 ± 45.5 min vs. 210.9 ± 44.5 min, P = 0.001). Other clinical parameters, such as the average bone mineral density (BMD), intraoperative blood loss, and postoperative hospital stay, were not significantly different. Oswestry disability index (ODI) and back pain visual analogue scale (VAS) scores were significantly improved in both groups compared with preoperatively. SPC guided screw placement was more accurate than the fluoroscopy-assisted FH technique for single-level MIDLF at L4/5. Patients undergoing SPC-guided screw placement can achieve similar clinical outcomes as the fluoroscopy-assisted FH technique. Nature Publishing Group UK 2023-09-30 /pmc/articles/PMC10542810/ /pubmed/37777594 http://dx.doi.org/10.1038/s41598-023-43406-1 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Zhang, Xi-nuo Su, Qing-jun Pei, Bao-qing Pan, Ai-xing Yang, Hong-hao Ding, Hong-tao Hai, Yong Liu, Yu-zeng The accuracy of cortical bone trajectory screw placement guided by spinous process clamp hardware in lumbar spinal surgery: a retrospective study |
title | The accuracy of cortical bone trajectory screw placement guided by spinous process clamp hardware in lumbar spinal surgery: a retrospective study |
title_full | The accuracy of cortical bone trajectory screw placement guided by spinous process clamp hardware in lumbar spinal surgery: a retrospective study |
title_fullStr | The accuracy of cortical bone trajectory screw placement guided by spinous process clamp hardware in lumbar spinal surgery: a retrospective study |
title_full_unstemmed | The accuracy of cortical bone trajectory screw placement guided by spinous process clamp hardware in lumbar spinal surgery: a retrospective study |
title_short | The accuracy of cortical bone trajectory screw placement guided by spinous process clamp hardware in lumbar spinal surgery: a retrospective study |
title_sort | accuracy of cortical bone trajectory screw placement guided by spinous process clamp hardware in lumbar spinal surgery: a retrospective study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10542810/ https://www.ncbi.nlm.nih.gov/pubmed/37777594 http://dx.doi.org/10.1038/s41598-023-43406-1 |
work_keys_str_mv | AT zhangxinuo theaccuracyofcorticalbonetrajectoryscrewplacementguidedbyspinousprocessclamphardwareinlumbarspinalsurgeryaretrospectivestudy AT suqingjun theaccuracyofcorticalbonetrajectoryscrewplacementguidedbyspinousprocessclamphardwareinlumbarspinalsurgeryaretrospectivestudy AT peibaoqing theaccuracyofcorticalbonetrajectoryscrewplacementguidedbyspinousprocessclamphardwareinlumbarspinalsurgeryaretrospectivestudy AT panaixing theaccuracyofcorticalbonetrajectoryscrewplacementguidedbyspinousprocessclamphardwareinlumbarspinalsurgeryaretrospectivestudy AT yanghonghao theaccuracyofcorticalbonetrajectoryscrewplacementguidedbyspinousprocessclamphardwareinlumbarspinalsurgeryaretrospectivestudy AT dinghongtao theaccuracyofcorticalbonetrajectoryscrewplacementguidedbyspinousprocessclamphardwareinlumbarspinalsurgeryaretrospectivestudy AT haiyong theaccuracyofcorticalbonetrajectoryscrewplacementguidedbyspinousprocessclamphardwareinlumbarspinalsurgeryaretrospectivestudy AT liuyuzeng theaccuracyofcorticalbonetrajectoryscrewplacementguidedbyspinousprocessclamphardwareinlumbarspinalsurgeryaretrospectivestudy AT zhangxinuo accuracyofcorticalbonetrajectoryscrewplacementguidedbyspinousprocessclamphardwareinlumbarspinalsurgeryaretrospectivestudy AT suqingjun accuracyofcorticalbonetrajectoryscrewplacementguidedbyspinousprocessclamphardwareinlumbarspinalsurgeryaretrospectivestudy AT peibaoqing accuracyofcorticalbonetrajectoryscrewplacementguidedbyspinousprocessclamphardwareinlumbarspinalsurgeryaretrospectivestudy AT panaixing accuracyofcorticalbonetrajectoryscrewplacementguidedbyspinousprocessclamphardwareinlumbarspinalsurgeryaretrospectivestudy AT yanghonghao accuracyofcorticalbonetrajectoryscrewplacementguidedbyspinousprocessclamphardwareinlumbarspinalsurgeryaretrospectivestudy AT dinghongtao accuracyofcorticalbonetrajectoryscrewplacementguidedbyspinousprocessclamphardwareinlumbarspinalsurgeryaretrospectivestudy AT haiyong accuracyofcorticalbonetrajectoryscrewplacementguidedbyspinousprocessclamphardwareinlumbarspinalsurgeryaretrospectivestudy AT liuyuzeng accuracyofcorticalbonetrajectoryscrewplacementguidedbyspinousprocessclamphardwareinlumbarspinalsurgeryaretrospectivestudy |