Cargando…
Application of a nerve stereoscopic reconstruction technique based on ultrasonic images in the diagnosis of neuralgic amyotrophy
Objective: To propose a nerve stereoscopic reconstruction technique based on ultrasound imaging for site diagnosis, intuitive reflection of disease severity, and classification of neuralgic amyotrophy (NA). Methods: We enrolled 44 patients with NA who underwent high-frequency ultrasonography examina...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10543234/ https://www.ncbi.nlm.nih.gov/pubmed/37791346 http://dx.doi.org/10.3389/fphys.2023.1201275 |
_version_ | 1785114256319971328 |
---|---|
author | Yu, Miao Ding, Wenquan Shao, Guoqing Li, Miaozhong Zhou, Xiaoling Liu, Linhai Li, Xueyuan |
author_facet | Yu, Miao Ding, Wenquan Shao, Guoqing Li, Miaozhong Zhou, Xiaoling Liu, Linhai Li, Xueyuan |
author_sort | Yu, Miao |
collection | PubMed |
description | Objective: To propose a nerve stereoscopic reconstruction technique based on ultrasound imaging for site diagnosis, intuitive reflection of disease severity, and classification of neuralgic amyotrophy (NA). Methods: We enrolled 44 patients with NA who underwent high-frequency ultrasonography examination. Multiple sites on the normal side and the affected side were scanned to calculate the ratio of the cross-section area (CSA) of the affected side to the normal side at each location measured, i.e., the cross-section area swelling ratio (CSASR). The CSASR of 44 patients and 30 normal controls was analyzed to determine their threshold value for the diagnosis of NA. Then, ultrasound images of the cross-section were used to reconstruct the stereoscopic model of the nerve on the affected side and the normal side. Using the CSASR values in each measurement location, a CSASR stereoscopic model was developed. Results: The threshold value of CSASR for ultrasound diagnosis of NA was 1.55. The average diseased segments per patient was 2.49 ± 1.97, with an average overall length of 10.03 ± 7.95 cm. Nerve stereoscopic reconstruction could be conducted for swelling, torsion, incomplete constriction, and complete constriction. Conclusion: The ultrasound image reconstruction method proposed in this study can accurately determine the site, range, and type of neuropathies in patients with NA, and simultaneously provide complete and accurate data information and intuitive morphological information. |
format | Online Article Text |
id | pubmed-10543234 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-105432342023-10-03 Application of a nerve stereoscopic reconstruction technique based on ultrasonic images in the diagnosis of neuralgic amyotrophy Yu, Miao Ding, Wenquan Shao, Guoqing Li, Miaozhong Zhou, Xiaoling Liu, Linhai Li, Xueyuan Front Physiol Physiology Objective: To propose a nerve stereoscopic reconstruction technique based on ultrasound imaging for site diagnosis, intuitive reflection of disease severity, and classification of neuralgic amyotrophy (NA). Methods: We enrolled 44 patients with NA who underwent high-frequency ultrasonography examination. Multiple sites on the normal side and the affected side were scanned to calculate the ratio of the cross-section area (CSA) of the affected side to the normal side at each location measured, i.e., the cross-section area swelling ratio (CSASR). The CSASR of 44 patients and 30 normal controls was analyzed to determine their threshold value for the diagnosis of NA. Then, ultrasound images of the cross-section were used to reconstruct the stereoscopic model of the nerve on the affected side and the normal side. Using the CSASR values in each measurement location, a CSASR stereoscopic model was developed. Results: The threshold value of CSASR for ultrasound diagnosis of NA was 1.55. The average diseased segments per patient was 2.49 ± 1.97, with an average overall length of 10.03 ± 7.95 cm. Nerve stereoscopic reconstruction could be conducted for swelling, torsion, incomplete constriction, and complete constriction. Conclusion: The ultrasound image reconstruction method proposed in this study can accurately determine the site, range, and type of neuropathies in patients with NA, and simultaneously provide complete and accurate data information and intuitive morphological information. Frontiers Media S.A. 2023-09-18 /pmc/articles/PMC10543234/ /pubmed/37791346 http://dx.doi.org/10.3389/fphys.2023.1201275 Text en Copyright © 2023 Yu, Ding, Shao, Li, Zhou, Liu and Li. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Physiology Yu, Miao Ding, Wenquan Shao, Guoqing Li, Miaozhong Zhou, Xiaoling Liu, Linhai Li, Xueyuan Application of a nerve stereoscopic reconstruction technique based on ultrasonic images in the diagnosis of neuralgic amyotrophy |
title | Application of a nerve stereoscopic reconstruction technique based on ultrasonic images in the diagnosis of neuralgic amyotrophy |
title_full | Application of a nerve stereoscopic reconstruction technique based on ultrasonic images in the diagnosis of neuralgic amyotrophy |
title_fullStr | Application of a nerve stereoscopic reconstruction technique based on ultrasonic images in the diagnosis of neuralgic amyotrophy |
title_full_unstemmed | Application of a nerve stereoscopic reconstruction technique based on ultrasonic images in the diagnosis of neuralgic amyotrophy |
title_short | Application of a nerve stereoscopic reconstruction technique based on ultrasonic images in the diagnosis of neuralgic amyotrophy |
title_sort | application of a nerve stereoscopic reconstruction technique based on ultrasonic images in the diagnosis of neuralgic amyotrophy |
topic | Physiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10543234/ https://www.ncbi.nlm.nih.gov/pubmed/37791346 http://dx.doi.org/10.3389/fphys.2023.1201275 |
work_keys_str_mv | AT yumiao applicationofanervestereoscopicreconstructiontechniquebasedonultrasonicimagesinthediagnosisofneuralgicamyotrophy AT dingwenquan applicationofanervestereoscopicreconstructiontechniquebasedonultrasonicimagesinthediagnosisofneuralgicamyotrophy AT shaoguoqing applicationofanervestereoscopicreconstructiontechniquebasedonultrasonicimagesinthediagnosisofneuralgicamyotrophy AT limiaozhong applicationofanervestereoscopicreconstructiontechniquebasedonultrasonicimagesinthediagnosisofneuralgicamyotrophy AT zhouxiaoling applicationofanervestereoscopicreconstructiontechniquebasedonultrasonicimagesinthediagnosisofneuralgicamyotrophy AT liulinhai applicationofanervestereoscopicreconstructiontechniquebasedonultrasonicimagesinthediagnosisofneuralgicamyotrophy AT lixueyuan applicationofanervestereoscopicreconstructiontechniquebasedonultrasonicimagesinthediagnosisofneuralgicamyotrophy |