Cargando…

Nanozymes based on octahedral platinum nanocrystals with {111} surface facets: glucose oxidase mimicking activity in electrochemical sensors

The ability of shape-controlled octahedral Pt nanoparticles to act as nanozyme mimicking glucose oxidase enzyme is reported. Extended {111} particle surface facets coupled with a size comparable to natural enzymes and easy-to-remove citrate coating give high affinity for glucose, comparable to the e...

Descripción completa

Detalles Bibliográficos
Autores principales: Mazzotta, Elisabetta, Di Giulio, Tiziano, Mastronardi, Valentina, Brescia, Rosaria, Pompa, Pier Paolo, Moglianetti, Mauro, Malitesta, Cosimino
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Vienna 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10543470/
https://www.ncbi.nlm.nih.gov/pubmed/37776360
http://dx.doi.org/10.1007/s00604-023-05992-9
_version_ 1785114303971459072
author Mazzotta, Elisabetta
Di Giulio, Tiziano
Mastronardi, Valentina
Brescia, Rosaria
Pompa, Pier Paolo
Moglianetti, Mauro
Malitesta, Cosimino
author_facet Mazzotta, Elisabetta
Di Giulio, Tiziano
Mastronardi, Valentina
Brescia, Rosaria
Pompa, Pier Paolo
Moglianetti, Mauro
Malitesta, Cosimino
author_sort Mazzotta, Elisabetta
collection PubMed
description The ability of shape-controlled octahedral Pt nanoparticles to act as nanozyme mimicking glucose oxidase enzyme is reported. Extended {111} particle surface facets coupled with a size comparable to natural enzymes and easy-to-remove citrate coating give high affinity for glucose, comparable to the enzyme as proven by the steady-state kinetics of glucose electrooxidation. The easy and thorough removal of the citrate coating, demonstrated by X-ray photoelectron spectroscopy analysis, allows a highly stable deposition of the nanozymes on the electrode. The glucose electrochemical detection (at −0.2 V vs SCE) shows a linear response between 0.36 and 17 mM with a limit of detection of 110 μM. A good reproducibility has been achieved, with an average relative standard deviation (RSD) value of 9.1% (n = 3). Similarly, a low intra-sensor variability has been observed, with a RSD of 6.6% (n = 3). Moreover, the sensor shows a long-term stability with reproducible performances for at least 2 months (RSD: 7.8%). Tests in saliva samples show the applicability of Pt nanozymes to commercial systems for non-invasive monitoring of hyperglycemia in saliva, with recoveries ranging from 92 to 98%. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00604-023-05992-9.
format Online
Article
Text
id pubmed-10543470
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer Vienna
record_format MEDLINE/PubMed
spelling pubmed-105434702023-10-03 Nanozymes based on octahedral platinum nanocrystals with {111} surface facets: glucose oxidase mimicking activity in electrochemical sensors Mazzotta, Elisabetta Di Giulio, Tiziano Mastronardi, Valentina Brescia, Rosaria Pompa, Pier Paolo Moglianetti, Mauro Malitesta, Cosimino Mikrochim Acta Original Paper The ability of shape-controlled octahedral Pt nanoparticles to act as nanozyme mimicking glucose oxidase enzyme is reported. Extended {111} particle surface facets coupled with a size comparable to natural enzymes and easy-to-remove citrate coating give high affinity for glucose, comparable to the enzyme as proven by the steady-state kinetics of glucose electrooxidation. The easy and thorough removal of the citrate coating, demonstrated by X-ray photoelectron spectroscopy analysis, allows a highly stable deposition of the nanozymes on the electrode. The glucose electrochemical detection (at −0.2 V vs SCE) shows a linear response between 0.36 and 17 mM with a limit of detection of 110 μM. A good reproducibility has been achieved, with an average relative standard deviation (RSD) value of 9.1% (n = 3). Similarly, a low intra-sensor variability has been observed, with a RSD of 6.6% (n = 3). Moreover, the sensor shows a long-term stability with reproducible performances for at least 2 months (RSD: 7.8%). Tests in saliva samples show the applicability of Pt nanozymes to commercial systems for non-invasive monitoring of hyperglycemia in saliva, with recoveries ranging from 92 to 98%. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00604-023-05992-9. Springer Vienna 2023-09-30 2023 /pmc/articles/PMC10543470/ /pubmed/37776360 http://dx.doi.org/10.1007/s00604-023-05992-9 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Paper
Mazzotta, Elisabetta
Di Giulio, Tiziano
Mastronardi, Valentina
Brescia, Rosaria
Pompa, Pier Paolo
Moglianetti, Mauro
Malitesta, Cosimino
Nanozymes based on octahedral platinum nanocrystals with {111} surface facets: glucose oxidase mimicking activity in electrochemical sensors
title Nanozymes based on octahedral platinum nanocrystals with {111} surface facets: glucose oxidase mimicking activity in electrochemical sensors
title_full Nanozymes based on octahedral platinum nanocrystals with {111} surface facets: glucose oxidase mimicking activity in electrochemical sensors
title_fullStr Nanozymes based on octahedral platinum nanocrystals with {111} surface facets: glucose oxidase mimicking activity in electrochemical sensors
title_full_unstemmed Nanozymes based on octahedral platinum nanocrystals with {111} surface facets: glucose oxidase mimicking activity in electrochemical sensors
title_short Nanozymes based on octahedral platinum nanocrystals with {111} surface facets: glucose oxidase mimicking activity in electrochemical sensors
title_sort nanozymes based on octahedral platinum nanocrystals with {111} surface facets: glucose oxidase mimicking activity in electrochemical sensors
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10543470/
https://www.ncbi.nlm.nih.gov/pubmed/37776360
http://dx.doi.org/10.1007/s00604-023-05992-9
work_keys_str_mv AT mazzottaelisabetta nanozymesbasedonoctahedralplatinumnanocrystalswith111surfacefacetsglucoseoxidasemimickingactivityinelectrochemicalsensors
AT digiuliotiziano nanozymesbasedonoctahedralplatinumnanocrystalswith111surfacefacetsglucoseoxidasemimickingactivityinelectrochemicalsensors
AT mastronardivalentina nanozymesbasedonoctahedralplatinumnanocrystalswith111surfacefacetsglucoseoxidasemimickingactivityinelectrochemicalsensors
AT bresciarosaria nanozymesbasedonoctahedralplatinumnanocrystalswith111surfacefacetsglucoseoxidasemimickingactivityinelectrochemicalsensors
AT pompapierpaolo nanozymesbasedonoctahedralplatinumnanocrystalswith111surfacefacetsglucoseoxidasemimickingactivityinelectrochemicalsensors
AT moglianettimauro nanozymesbasedonoctahedralplatinumnanocrystalswith111surfacefacetsglucoseoxidasemimickingactivityinelectrochemicalsensors
AT malitestacosimino nanozymesbasedonoctahedralplatinumnanocrystalswith111surfacefacetsglucoseoxidasemimickingactivityinelectrochemicalsensors