Remote and automated high-throughput powder diffraction measurements enabled by a robotic sample changer at SSRL beamline 2-1
The general-purpose powder diffractometer beamline (BL2-1) at the Stanford Synchrotron Radiation Lightsource (SSRL) is described. The evolution of design and performance of BL2-1 are presented, in addition to current operating specifications, applications and measurement capabilities. Recent develop...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Union of Crystallography
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10543666/ https://www.ncbi.nlm.nih.gov/pubmed/37791352 http://dx.doi.org/10.1107/S1600576723007148 |
_version_ | 1785114330691272704 |
---|---|
author | Stone, Kevin H. Cosby, Monty R. Strange, Nicholas A. Thampy, Vivek Walroth, Richard C. Troxel Jr, Charles |
author_facet | Stone, Kevin H. Cosby, Monty R. Strange, Nicholas A. Thampy, Vivek Walroth, Richard C. Troxel Jr, Charles |
author_sort | Stone, Kevin H. |
collection | PubMed |
description | The general-purpose powder diffractometer beamline (BL2-1) at the Stanford Synchrotron Radiation Lightsource (SSRL) is described. The evolution of design and performance of BL2-1 are presented, in addition to current operating specifications, applications and measurement capabilities. Recent developments involve a robotic sample changer enabling high-throughput X-ray diffraction measurements, applicable to mail-in and remote operations. In situ and operando capabilities to measure samples with different form factors (e.g. capillary, flat plate or thin film, and transmission) and under variable experimental conditions are discussed. Several example datasets and accompanying Rietveld refinements are presented. |
format | Online Article Text |
id | pubmed-10543666 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | International Union of Crystallography |
record_format | MEDLINE/PubMed |
spelling | pubmed-105436662023-10-03 Remote and automated high-throughput powder diffraction measurements enabled by a robotic sample changer at SSRL beamline 2-1 Stone, Kevin H. Cosby, Monty R. Strange, Nicholas A. Thampy, Vivek Walroth, Richard C. Troxel Jr, Charles J Appl Crystallogr Research Papers The general-purpose powder diffractometer beamline (BL2-1) at the Stanford Synchrotron Radiation Lightsource (SSRL) is described. The evolution of design and performance of BL2-1 are presented, in addition to current operating specifications, applications and measurement capabilities. Recent developments involve a robotic sample changer enabling high-throughput X-ray diffraction measurements, applicable to mail-in and remote operations. In situ and operando capabilities to measure samples with different form factors (e.g. capillary, flat plate or thin film, and transmission) and under variable experimental conditions are discussed. Several example datasets and accompanying Rietveld refinements are presented. International Union of Crystallography 2023-09-20 /pmc/articles/PMC10543666/ /pubmed/37791352 http://dx.doi.org/10.1107/S1600576723007148 Text en © Kevin H. Stone et al. 2023 https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited. |
spellingShingle | Research Papers Stone, Kevin H. Cosby, Monty R. Strange, Nicholas A. Thampy, Vivek Walroth, Richard C. Troxel Jr, Charles Remote and automated high-throughput powder diffraction measurements enabled by a robotic sample changer at SSRL beamline 2-1 |
title | Remote and automated high-throughput powder diffraction measurements enabled by a robotic sample changer at SSRL beamline 2-1 |
title_full | Remote and automated high-throughput powder diffraction measurements enabled by a robotic sample changer at SSRL beamline 2-1 |
title_fullStr | Remote and automated high-throughput powder diffraction measurements enabled by a robotic sample changer at SSRL beamline 2-1 |
title_full_unstemmed | Remote and automated high-throughput powder diffraction measurements enabled by a robotic sample changer at SSRL beamline 2-1 |
title_short | Remote and automated high-throughput powder diffraction measurements enabled by a robotic sample changer at SSRL beamline 2-1 |
title_sort | remote and automated high-throughput powder diffraction measurements enabled by a robotic sample changer at ssrl beamline 2-1 |
topic | Research Papers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10543666/ https://www.ncbi.nlm.nih.gov/pubmed/37791352 http://dx.doi.org/10.1107/S1600576723007148 |
work_keys_str_mv | AT stonekevinh remoteandautomatedhighthroughputpowderdiffractionmeasurementsenabledbyaroboticsamplechangeratssrlbeamline21 AT cosbymontyr remoteandautomatedhighthroughputpowderdiffractionmeasurementsenabledbyaroboticsamplechangeratssrlbeamline21 AT strangenicholasa remoteandautomatedhighthroughputpowderdiffractionmeasurementsenabledbyaroboticsamplechangeratssrlbeamline21 AT thampyvivek remoteandautomatedhighthroughputpowderdiffractionmeasurementsenabledbyaroboticsamplechangeratssrlbeamline21 AT walrothrichardc remoteandautomatedhighthroughputpowderdiffractionmeasurementsenabledbyaroboticsamplechangeratssrlbeamline21 AT troxeljrcharles remoteandautomatedhighthroughputpowderdiffractionmeasurementsenabledbyaroboticsamplechangeratssrlbeamline21 |