Cargando…

Investigation of the optimal indocyanine green dose in real-time fluorescent cholangiography during laparoscopic cholecystectomy with an ultra-high-definition 4K fluorescent system: a randomized controlled trial

This study aimed to investigate the indocyanine green (ICG) dose in real‐time fluorescent cholangiography during laparoscopic cholecystectomy (LC) with a 4K fluorescent system. A randomized controlled clinical trial was conducted in patients who underwent LC for treatment of cholelithiasis. Using th...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Hui, Kuang, Jiao, Xu, Yujie, Li, Tianyang, Li, Peilin, Huang, Zisheng, Zhang, Shuai, Weng, Jiefeng, Lai, Yueyuan, Wu, Zhaofeng, Lin, Fan, Gu, Weili, Huang, Yu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10543949/
https://www.ncbi.nlm.nih.gov/pubmed/37314620
http://dx.doi.org/10.1007/s13304-023-01557-w
_version_ 1785114395418820608
author Liu, Hui
Kuang, Jiao
Xu, Yujie
Li, Tianyang
Li, Peilin
Huang, Zisheng
Zhang, Shuai
Weng, Jiefeng
Lai, Yueyuan
Wu, Zhaofeng
Lin, Fan
Gu, Weili
Huang, Yu
author_facet Liu, Hui
Kuang, Jiao
Xu, Yujie
Li, Tianyang
Li, Peilin
Huang, Zisheng
Zhang, Shuai
Weng, Jiefeng
Lai, Yueyuan
Wu, Zhaofeng
Lin, Fan
Gu, Weili
Huang, Yu
author_sort Liu, Hui
collection PubMed
description This study aimed to investigate the indocyanine green (ICG) dose in real‐time fluorescent cholangiography during laparoscopic cholecystectomy (LC) with a 4K fluorescent system. A randomized controlled clinical trial was conducted in patients who underwent LC for treatment of cholelithiasis. Using the OptoMedic 4K fluorescent endoscopic system, we compared four different doses of ICG (1, 10, 25, and 100 µg) administered intravenously within 30 min preoperatively and evaluated the fluorescence intensity (FI) of the common bile duct and liver background and the bile-to-liver ratio (BLR) of the FI at three timepoints: before surgical dissection of the cystohepatic triangle, before clipping the cystic duct, and before closure. Forty patients were randomized into four groups, and 33 patients were fully analyzed, with 10 patients in Group A (1 µg), 7 patients in Group B (10 µg), 9 patients in Group C (25 µg), and 7 patients in Group D (100 µg). The preoperative baseline characteristics were compared among groups (p > 0.05). Group A showed no or minimal FI in the bile duct and liver background, while Group D showed extremely high FIs in the bile duct and in the liver background at the three timepoints. Groups B and C presented with visible FI in the bile duct and low FI in the liver background. With increasing ICG doses, the FIs in the liver background and bile duct gradually increased at the three timepoints. The BLR, however, showed no increasing trend with an increasing ICG dose. A relatively high BLR on average was found in Group B, without a significant difference compared to the other groups (p > 0.05). An ICG dose ranging from 10 to 25 µg by intravenous administration within 30 min preoperatively was appropriate for real‐time fluorescent cholangiography in LC with a 4K fluorescent system. Registration: This study was registered in the Chinese Clinical Trial Registry (ChiCTR No: ChiCTR2200064726). SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s13304-023-01557-w.
format Online
Article
Text
id pubmed-10543949
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-105439492023-10-03 Investigation of the optimal indocyanine green dose in real-time fluorescent cholangiography during laparoscopic cholecystectomy with an ultra-high-definition 4K fluorescent system: a randomized controlled trial Liu, Hui Kuang, Jiao Xu, Yujie Li, Tianyang Li, Peilin Huang, Zisheng Zhang, Shuai Weng, Jiefeng Lai, Yueyuan Wu, Zhaofeng Lin, Fan Gu, Weili Huang, Yu Updates Surg Original Article This study aimed to investigate the indocyanine green (ICG) dose in real‐time fluorescent cholangiography during laparoscopic cholecystectomy (LC) with a 4K fluorescent system. A randomized controlled clinical trial was conducted in patients who underwent LC for treatment of cholelithiasis. Using the OptoMedic 4K fluorescent endoscopic system, we compared four different doses of ICG (1, 10, 25, and 100 µg) administered intravenously within 30 min preoperatively and evaluated the fluorescence intensity (FI) of the common bile duct and liver background and the bile-to-liver ratio (BLR) of the FI at three timepoints: before surgical dissection of the cystohepatic triangle, before clipping the cystic duct, and before closure. Forty patients were randomized into four groups, and 33 patients were fully analyzed, with 10 patients in Group A (1 µg), 7 patients in Group B (10 µg), 9 patients in Group C (25 µg), and 7 patients in Group D (100 µg). The preoperative baseline characteristics were compared among groups (p > 0.05). Group A showed no or minimal FI in the bile duct and liver background, while Group D showed extremely high FIs in the bile duct and in the liver background at the three timepoints. Groups B and C presented with visible FI in the bile duct and low FI in the liver background. With increasing ICG doses, the FIs in the liver background and bile duct gradually increased at the three timepoints. The BLR, however, showed no increasing trend with an increasing ICG dose. A relatively high BLR on average was found in Group B, without a significant difference compared to the other groups (p > 0.05). An ICG dose ranging from 10 to 25 µg by intravenous administration within 30 min preoperatively was appropriate for real‐time fluorescent cholangiography in LC with a 4K fluorescent system. Registration: This study was registered in the Chinese Clinical Trial Registry (ChiCTR No: ChiCTR2200064726). SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s13304-023-01557-w. Springer International Publishing 2023-06-14 2023 /pmc/articles/PMC10543949/ /pubmed/37314620 http://dx.doi.org/10.1007/s13304-023-01557-w Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Liu, Hui
Kuang, Jiao
Xu, Yujie
Li, Tianyang
Li, Peilin
Huang, Zisheng
Zhang, Shuai
Weng, Jiefeng
Lai, Yueyuan
Wu, Zhaofeng
Lin, Fan
Gu, Weili
Huang, Yu
Investigation of the optimal indocyanine green dose in real-time fluorescent cholangiography during laparoscopic cholecystectomy with an ultra-high-definition 4K fluorescent system: a randomized controlled trial
title Investigation of the optimal indocyanine green dose in real-time fluorescent cholangiography during laparoscopic cholecystectomy with an ultra-high-definition 4K fluorescent system: a randomized controlled trial
title_full Investigation of the optimal indocyanine green dose in real-time fluorescent cholangiography during laparoscopic cholecystectomy with an ultra-high-definition 4K fluorescent system: a randomized controlled trial
title_fullStr Investigation of the optimal indocyanine green dose in real-time fluorescent cholangiography during laparoscopic cholecystectomy with an ultra-high-definition 4K fluorescent system: a randomized controlled trial
title_full_unstemmed Investigation of the optimal indocyanine green dose in real-time fluorescent cholangiography during laparoscopic cholecystectomy with an ultra-high-definition 4K fluorescent system: a randomized controlled trial
title_short Investigation of the optimal indocyanine green dose in real-time fluorescent cholangiography during laparoscopic cholecystectomy with an ultra-high-definition 4K fluorescent system: a randomized controlled trial
title_sort investigation of the optimal indocyanine green dose in real-time fluorescent cholangiography during laparoscopic cholecystectomy with an ultra-high-definition 4k fluorescent system: a randomized controlled trial
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10543949/
https://www.ncbi.nlm.nih.gov/pubmed/37314620
http://dx.doi.org/10.1007/s13304-023-01557-w
work_keys_str_mv AT liuhui investigationoftheoptimalindocyaninegreendoseinrealtimefluorescentcholangiographyduringlaparoscopiccholecystectomywithanultrahighdefinition4kfluorescentsystemarandomizedcontrolledtrial
AT kuangjiao investigationoftheoptimalindocyaninegreendoseinrealtimefluorescentcholangiographyduringlaparoscopiccholecystectomywithanultrahighdefinition4kfluorescentsystemarandomizedcontrolledtrial
AT xuyujie investigationoftheoptimalindocyaninegreendoseinrealtimefluorescentcholangiographyduringlaparoscopiccholecystectomywithanultrahighdefinition4kfluorescentsystemarandomizedcontrolledtrial
AT litianyang investigationoftheoptimalindocyaninegreendoseinrealtimefluorescentcholangiographyduringlaparoscopiccholecystectomywithanultrahighdefinition4kfluorescentsystemarandomizedcontrolledtrial
AT lipeilin investigationoftheoptimalindocyaninegreendoseinrealtimefluorescentcholangiographyduringlaparoscopiccholecystectomywithanultrahighdefinition4kfluorescentsystemarandomizedcontrolledtrial
AT huangzisheng investigationoftheoptimalindocyaninegreendoseinrealtimefluorescentcholangiographyduringlaparoscopiccholecystectomywithanultrahighdefinition4kfluorescentsystemarandomizedcontrolledtrial
AT zhangshuai investigationoftheoptimalindocyaninegreendoseinrealtimefluorescentcholangiographyduringlaparoscopiccholecystectomywithanultrahighdefinition4kfluorescentsystemarandomizedcontrolledtrial
AT wengjiefeng investigationoftheoptimalindocyaninegreendoseinrealtimefluorescentcholangiographyduringlaparoscopiccholecystectomywithanultrahighdefinition4kfluorescentsystemarandomizedcontrolledtrial
AT laiyueyuan investigationoftheoptimalindocyaninegreendoseinrealtimefluorescentcholangiographyduringlaparoscopiccholecystectomywithanultrahighdefinition4kfluorescentsystemarandomizedcontrolledtrial
AT wuzhaofeng investigationoftheoptimalindocyaninegreendoseinrealtimefluorescentcholangiographyduringlaparoscopiccholecystectomywithanultrahighdefinition4kfluorescentsystemarandomizedcontrolledtrial
AT linfan investigationoftheoptimalindocyaninegreendoseinrealtimefluorescentcholangiographyduringlaparoscopiccholecystectomywithanultrahighdefinition4kfluorescentsystemarandomizedcontrolledtrial
AT guweili investigationoftheoptimalindocyaninegreendoseinrealtimefluorescentcholangiographyduringlaparoscopiccholecystectomywithanultrahighdefinition4kfluorescentsystemarandomizedcontrolledtrial
AT huangyu investigationoftheoptimalindocyaninegreendoseinrealtimefluorescentcholangiographyduringlaparoscopiccholecystectomywithanultrahighdefinition4kfluorescentsystemarandomizedcontrolledtrial