Integrating the Left Atrium Diameter to Improve the Predictive Ability of the Age, Creatinine, and Ejection Fraction Score for Atrial Fibrillation Recurrence After Cryoballoon Ablation

BACKGROUND: Several clinical trials have assessed predictors for atrial fibrillation recurrence following cryoballoon catheter ablation. With these predictors, a practical and new scoring system can be developed to evaluate atrial fibrillation recurrence. The present study aimed to analyze the predi...

Descripción completa

Detalles Bibliográficos
Autores principales: Taylan, Gökay, Gök, Murat, Kurtul, Alparslan, Uslu, Abdulkadir, Küp, Ayhan, Demir, Serdar, Gülşen, Kamil, Altay, Servet, Akgün, Taylan, Yalta, Kenan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Turkish Society of Cardiology 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10546214/
https://www.ncbi.nlm.nih.gov/pubmed/37329114
http://dx.doi.org/10.14744/AnatolJCardiol.2023.2857
_version_ 1785114827462541312
author Taylan, Gökay
Gök, Murat
Kurtul, Alparslan
Uslu, Abdulkadir
Küp, Ayhan
Demir, Serdar
Gülşen, Kamil
Altay, Servet
Akgün, Taylan
Yalta, Kenan
author_facet Taylan, Gökay
Gök, Murat
Kurtul, Alparslan
Uslu, Abdulkadir
Küp, Ayhan
Demir, Serdar
Gülşen, Kamil
Altay, Servet
Akgün, Taylan
Yalta, Kenan
author_sort Taylan, Gökay
collection PubMed
description BACKGROUND: Several clinical trials have assessed predictors for atrial fibrillation recurrence following cryoballoon catheter ablation. With these predictors, a practical and new scoring system can be developed to evaluate atrial fibrillation recurrence. The present study aimed to analyze the predictive value of the age, creatinine, and ejection fraction-left atrium score for potential recurrence of atrial fibrillation following cryoballoon catheter ablation in patients with symptomatic paroxysmal or persistent atrial fibrillation. METHODS: We retrospectively analyzed records of patients undergoing cryoballoon catheter ablation. atrial fibrillation recurrence was defined as an emerging atrial fibrillation episode around 12-month follow-up (with the exclusion of a 3-month blanking period). Univariate and multivariate analyses were performed to assess predictors of atrial fibrillation recurrence. In addition, receiver operating characteristic analysis was harnessed to evaluate the performance of the age, creatinine, and ejection fraction, left atrium score in determining the risk of atrial fibrillation recurrence. RESULTS: The study population comprised 106 subjects (age 52 ± 13 years, 63.2% women) with paroxysmal (84.9%, n = 90) or persistent (15.1%, n = 16) atrial fibrillation. age, creatinine, and ejection fraction, left atrium score was significantly higher in subjects with atrial fibrillation recurrence in comparison to those with the maintenance of sinus rhythm. However, on multivariate logistic regression analysis, only the age, creatinine, and ejection fraction, left atrium score (OR = 12.93, 95% CI: 2.22-75.21, P = .004) served as an independent predictor of atrial fibrillation recurrence following cryoballoon catheter ablation. CONCLUSION: Age, creatinine, and ejection fraction, left atrium score had an independent association with the risk of atrial fibrillation recurrence in subjects with atrial fibrillation undergoing cryoballoon catheter ablation. Therefore, this score might potentially serve as a useful tool for risk stratification of patients with atrial fibrillation.
format Online
Article
Text
id pubmed-10546214
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Turkish Society of Cardiology
record_format MEDLINE/PubMed
spelling pubmed-105462142023-10-04 Integrating the Left Atrium Diameter to Improve the Predictive Ability of the Age, Creatinine, and Ejection Fraction Score for Atrial Fibrillation Recurrence After Cryoballoon Ablation Taylan, Gökay Gök, Murat Kurtul, Alparslan Uslu, Abdulkadir Küp, Ayhan Demir, Serdar Gülşen, Kamil Altay, Servet Akgün, Taylan Yalta, Kenan Anatol J Cardiol Original Investigation BACKGROUND: Several clinical trials have assessed predictors for atrial fibrillation recurrence following cryoballoon catheter ablation. With these predictors, a practical and new scoring system can be developed to evaluate atrial fibrillation recurrence. The present study aimed to analyze the predictive value of the age, creatinine, and ejection fraction-left atrium score for potential recurrence of atrial fibrillation following cryoballoon catheter ablation in patients with symptomatic paroxysmal or persistent atrial fibrillation. METHODS: We retrospectively analyzed records of patients undergoing cryoballoon catheter ablation. atrial fibrillation recurrence was defined as an emerging atrial fibrillation episode around 12-month follow-up (with the exclusion of a 3-month blanking period). Univariate and multivariate analyses were performed to assess predictors of atrial fibrillation recurrence. In addition, receiver operating characteristic analysis was harnessed to evaluate the performance of the age, creatinine, and ejection fraction, left atrium score in determining the risk of atrial fibrillation recurrence. RESULTS: The study population comprised 106 subjects (age 52 ± 13 years, 63.2% women) with paroxysmal (84.9%, n = 90) or persistent (15.1%, n = 16) atrial fibrillation. age, creatinine, and ejection fraction, left atrium score was significantly higher in subjects with atrial fibrillation recurrence in comparison to those with the maintenance of sinus rhythm. However, on multivariate logistic regression analysis, only the age, creatinine, and ejection fraction, left atrium score (OR = 12.93, 95% CI: 2.22-75.21, P = .004) served as an independent predictor of atrial fibrillation recurrence following cryoballoon catheter ablation. CONCLUSION: Age, creatinine, and ejection fraction, left atrium score had an independent association with the risk of atrial fibrillation recurrence in subjects with atrial fibrillation undergoing cryoballoon catheter ablation. Therefore, this score might potentially serve as a useful tool for risk stratification of patients with atrial fibrillation. Turkish Society of Cardiology 2023-10-01 /pmc/articles/PMC10546214/ /pubmed/37329114 http://dx.doi.org/10.14744/AnatolJCardiol.2023.2857 Text en 2023 authors https://creativecommons.org/licenses/by-nc/4.0/ Content of this journal is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License. (https://creativecommons.org/licenses/by-nc/4.0/)
spellingShingle Original Investigation
Taylan, Gökay
Gök, Murat
Kurtul, Alparslan
Uslu, Abdulkadir
Küp, Ayhan
Demir, Serdar
Gülşen, Kamil
Altay, Servet
Akgün, Taylan
Yalta, Kenan
Integrating the Left Atrium Diameter to Improve the Predictive Ability of the Age, Creatinine, and Ejection Fraction Score for Atrial Fibrillation Recurrence After Cryoballoon Ablation
title Integrating the Left Atrium Diameter to Improve the Predictive Ability of the Age, Creatinine, and Ejection Fraction Score for Atrial Fibrillation Recurrence After Cryoballoon Ablation
title_full Integrating the Left Atrium Diameter to Improve the Predictive Ability of the Age, Creatinine, and Ejection Fraction Score for Atrial Fibrillation Recurrence After Cryoballoon Ablation
title_fullStr Integrating the Left Atrium Diameter to Improve the Predictive Ability of the Age, Creatinine, and Ejection Fraction Score for Atrial Fibrillation Recurrence After Cryoballoon Ablation
title_full_unstemmed Integrating the Left Atrium Diameter to Improve the Predictive Ability of the Age, Creatinine, and Ejection Fraction Score for Atrial Fibrillation Recurrence After Cryoballoon Ablation
title_short Integrating the Left Atrium Diameter to Improve the Predictive Ability of the Age, Creatinine, and Ejection Fraction Score for Atrial Fibrillation Recurrence After Cryoballoon Ablation
title_sort integrating the left atrium diameter to improve the predictive ability of the age, creatinine, and ejection fraction score for atrial fibrillation recurrence after cryoballoon ablation
topic Original Investigation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10546214/
https://www.ncbi.nlm.nih.gov/pubmed/37329114
http://dx.doi.org/10.14744/AnatolJCardiol.2023.2857
work_keys_str_mv AT taylangokay integratingtheleftatriumdiametertoimprovethepredictiveabilityoftheagecreatinineandejectionfractionscoreforatrialfibrillationrecurrenceaftercryoballoonablation
AT gokmurat integratingtheleftatriumdiametertoimprovethepredictiveabilityoftheagecreatinineandejectionfractionscoreforatrialfibrillationrecurrenceaftercryoballoonablation
AT kurtulalparslan integratingtheleftatriumdiametertoimprovethepredictiveabilityoftheagecreatinineandejectionfractionscoreforatrialfibrillationrecurrenceaftercryoballoonablation
AT usluabdulkadir integratingtheleftatriumdiametertoimprovethepredictiveabilityoftheagecreatinineandejectionfractionscoreforatrialfibrillationrecurrenceaftercryoballoonablation
AT kupayhan integratingtheleftatriumdiametertoimprovethepredictiveabilityoftheagecreatinineandejectionfractionscoreforatrialfibrillationrecurrenceaftercryoballoonablation
AT demirserdar integratingtheleftatriumdiametertoimprovethepredictiveabilityoftheagecreatinineandejectionfractionscoreforatrialfibrillationrecurrenceaftercryoballoonablation
AT gulsenkamil integratingtheleftatriumdiametertoimprovethepredictiveabilityoftheagecreatinineandejectionfractionscoreforatrialfibrillationrecurrenceaftercryoballoonablation
AT altayservet integratingtheleftatriumdiametertoimprovethepredictiveabilityoftheagecreatinineandejectionfractionscoreforatrialfibrillationrecurrenceaftercryoballoonablation
AT akguntaylan integratingtheleftatriumdiametertoimprovethepredictiveabilityoftheagecreatinineandejectionfractionscoreforatrialfibrillationrecurrenceaftercryoballoonablation
AT yaltakenan integratingtheleftatriumdiametertoimprovethepredictiveabilityoftheagecreatinineandejectionfractionscoreforatrialfibrillationrecurrenceaftercryoballoonablation