Cargando…

Aspiration thrombectomy with the Penumbra System for patients with stroke and late onset to treatment: a subset analysis of the COMPLETE registry

BACKGROUND: The purpose of this study was to report the safety and performance of aspiration thrombectomy with the Penumbra System for patients with acute ischemic stroke (AIS) due to anterior circulation large vessel occlusion (LVO) and late onset to treatment. METHODS: This is a retrospective subs...

Descripción completa

Detalles Bibliográficos
Autores principales: Hassan, Ameer E., Fifi, Johanna T., Zaidat, Osama O.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10546392/
https://www.ncbi.nlm.nih.gov/pubmed/37794880
http://dx.doi.org/10.3389/fneur.2023.1239640
_version_ 1785114858567499776
author Hassan, Ameer E.
Fifi, Johanna T.
Zaidat, Osama O.
author_facet Hassan, Ameer E.
Fifi, Johanna T.
Zaidat, Osama O.
author_sort Hassan, Ameer E.
collection PubMed
description BACKGROUND: The purpose of this study was to report the safety and performance of aspiration thrombectomy with the Penumbra System for patients with acute ischemic stroke (AIS) due to anterior circulation large vessel occlusion (LVO) and late onset to treatment. METHODS: This is a retrospective subset analysis of a global prospective multicenter registry (COMPLETE) that enrolled adults with AIS due to LVO and a pre-stroke modified Rankin Scale score (mRS) of 0 or 1 who were treated first-line with aspiration thrombectomy either alone (A Direct Aspiration First Pass Technique [ADAPT]) or in combination with the 3D Revascularization Device (ADAPT + 3D). This subset analysis included all patients in the registry who had anterior circulation LVO, an Alberta Stroke Program Early CT Score of at least 6, and late onset to treatment (>6 h from stroke onset to puncture). RESULTS: Of the 650 patients in the COMPLETE registry, 167 were included in this subset analysis. The rate of successful revascularization (modified thrombolysis in cerebral infarction score 2b-3 achieved) at the end of the procedure was 83.2%, the rate of good functional outcome (mRS 0–2) at 90 days was 55.4%, and the all-cause mortality rate at 90 days was 14.4%. No device-related serious adverse events (SAEs) occurred. Procedure-related SAEs occurred in 9 patients (5.4%) within 24 h and in 12 patients (7.2%) overall. The rate of successful revascularization was higher for patients treated first-line with ADAPT (88.0%) than for patients treated first-line with ADAPT + 3D (75.0%; p = 0.035); no significant difference was observed between the ADAPT and ADAPT + 3D groups for any other primary or secondary outcome. CONCLUSION: For patients with AIS due to anterior circulation LVO and with late onset to treatment, aspiration thrombectomy with the Penumbra System appears to be safe and effective. The rates of good functional outcome and all-cause mortality from this study compared favorably with those rates from the medical management arms of the DAWN and DEFUSE-3 studies. CLINICAL TRIAL REGISTRATION: https://www.clinicaltrials.gov, NCT03464565.
format Online
Article
Text
id pubmed-10546392
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-105463922023-10-04 Aspiration thrombectomy with the Penumbra System for patients with stroke and late onset to treatment: a subset analysis of the COMPLETE registry Hassan, Ameer E. Fifi, Johanna T. Zaidat, Osama O. Front Neurol Neurology BACKGROUND: The purpose of this study was to report the safety and performance of aspiration thrombectomy with the Penumbra System for patients with acute ischemic stroke (AIS) due to anterior circulation large vessel occlusion (LVO) and late onset to treatment. METHODS: This is a retrospective subset analysis of a global prospective multicenter registry (COMPLETE) that enrolled adults with AIS due to LVO and a pre-stroke modified Rankin Scale score (mRS) of 0 or 1 who were treated first-line with aspiration thrombectomy either alone (A Direct Aspiration First Pass Technique [ADAPT]) or in combination with the 3D Revascularization Device (ADAPT + 3D). This subset analysis included all patients in the registry who had anterior circulation LVO, an Alberta Stroke Program Early CT Score of at least 6, and late onset to treatment (>6 h from stroke onset to puncture). RESULTS: Of the 650 patients in the COMPLETE registry, 167 were included in this subset analysis. The rate of successful revascularization (modified thrombolysis in cerebral infarction score 2b-3 achieved) at the end of the procedure was 83.2%, the rate of good functional outcome (mRS 0–2) at 90 days was 55.4%, and the all-cause mortality rate at 90 days was 14.4%. No device-related serious adverse events (SAEs) occurred. Procedure-related SAEs occurred in 9 patients (5.4%) within 24 h and in 12 patients (7.2%) overall. The rate of successful revascularization was higher for patients treated first-line with ADAPT (88.0%) than for patients treated first-line with ADAPT + 3D (75.0%; p = 0.035); no significant difference was observed between the ADAPT and ADAPT + 3D groups for any other primary or secondary outcome. CONCLUSION: For patients with AIS due to anterior circulation LVO and with late onset to treatment, aspiration thrombectomy with the Penumbra System appears to be safe and effective. The rates of good functional outcome and all-cause mortality from this study compared favorably with those rates from the medical management arms of the DAWN and DEFUSE-3 studies. CLINICAL TRIAL REGISTRATION: https://www.clinicaltrials.gov, NCT03464565. Frontiers Media S.A. 2023-09-14 /pmc/articles/PMC10546392/ /pubmed/37794880 http://dx.doi.org/10.3389/fneur.2023.1239640 Text en Copyright © 2023 Hassan, Fifi and Zaidat. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Neurology
Hassan, Ameer E.
Fifi, Johanna T.
Zaidat, Osama O.
Aspiration thrombectomy with the Penumbra System for patients with stroke and late onset to treatment: a subset analysis of the COMPLETE registry
title Aspiration thrombectomy with the Penumbra System for patients with stroke and late onset to treatment: a subset analysis of the COMPLETE registry
title_full Aspiration thrombectomy with the Penumbra System for patients with stroke and late onset to treatment: a subset analysis of the COMPLETE registry
title_fullStr Aspiration thrombectomy with the Penumbra System for patients with stroke and late onset to treatment: a subset analysis of the COMPLETE registry
title_full_unstemmed Aspiration thrombectomy with the Penumbra System for patients with stroke and late onset to treatment: a subset analysis of the COMPLETE registry
title_short Aspiration thrombectomy with the Penumbra System for patients with stroke and late onset to treatment: a subset analysis of the COMPLETE registry
title_sort aspiration thrombectomy with the penumbra system for patients with stroke and late onset to treatment: a subset analysis of the complete registry
topic Neurology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10546392/
https://www.ncbi.nlm.nih.gov/pubmed/37794880
http://dx.doi.org/10.3389/fneur.2023.1239640
work_keys_str_mv AT hassanameere aspirationthrombectomywiththepenumbrasystemforpatientswithstrokeandlateonsettotreatmentasubsetanalysisofthecompleteregistry
AT fifijohannat aspirationthrombectomywiththepenumbrasystemforpatientswithstrokeandlateonsettotreatmentasubsetanalysisofthecompleteregistry
AT zaidatosamao aspirationthrombectomywiththepenumbrasystemforpatientswithstrokeandlateonsettotreatmentasubsetanalysisofthecompleteregistry