Cargando…
Electrophysiological findings during re-do procedures after single-shot pulmonary vein isolation for atrial fibrillation with pulsed field ablation
BACKGROUND: Pulsed field ablation (PFA) is a novel ablation technology recently adopted in the treatment of atrial fibrillation (AF). Currently, little is known about the durability of PFA ablation lesions. METHODS: We investigated patients who underwent redo-ablation due to recurrent AF/atrial-flut...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer US
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10547612/ https://www.ncbi.nlm.nih.gov/pubmed/37195355 http://dx.doi.org/10.1007/s10840-023-01559-z |
_version_ | 1785115090240929792 |
---|---|
author | Magni, Federico Tancredi Scherr, Daniel Manninger, Martin Sohns, Christian Sommer, Philip Hovakimyan, Tatevik Blaauw, Yuri Mulder, Bart A. |
author_facet | Magni, Federico Tancredi Scherr, Daniel Manninger, Martin Sohns, Christian Sommer, Philip Hovakimyan, Tatevik Blaauw, Yuri Mulder, Bart A. |
author_sort | Magni, Federico Tancredi |
collection | PubMed |
description | BACKGROUND: Pulsed field ablation (PFA) is a novel ablation technology recently adopted in the treatment of atrial fibrillation (AF). Currently, little is known about the durability of PFA ablation lesions. METHODS: We investigated patients who underwent redo-ablation due to recurrent AF/atrial-flutter or tachycardia (AFL/AT) following PVI with PFA. We report electrophysiological findings and ablation strategy during redo-ablation. RESULTS: Of 447 patients undergoing index PVI with PFA, 14 patients (age: 61.9±10.8 years; 7 (50.0%) males; left atrial volume index (n=10): 39.4±14.6 mL/m(2)) were referred for redo-ablation. Initial indication was paroxysmal-AF in 7 patients, persistent-AF in 6 and long-standing-persistent-AF in one patient. Mean time-to-recurrence was 4.9±1.9 months. Three patients received additional posterior-wall-isolation during index PFA. Twelve (85.7%) patients suffered AF recurrence and 5/12 had concomitant AFL. In the remaining 2 patients, one had a (box-dependent) AFL, and one had an atypical AT. No patients had all PVs reconnected. Reconnection in zero, one, two or three PVs was found in 35.7%, 21.4%, 14.3%, and 28.6% of patients, respectively. All 7 patients with zero or one reconnection with AF recurrence received additional/repeat posterior-wall-isolation during re-ablation, while in the others, PVs were re-isolated. Patients with only AFL/AT had no reconnection of PVs, and the substrate was successfully ablated. CONCLUSIONS: Durable PVI (all PV’s isolated) was observed in over one-third of patients at re-do. The predominant recurrent arrhythmia following PVI-only was AF. Concomitant (35.7%) or isolated (14.3%) AFL/AT recurrence was observed in 50% of patients. |
format | Online Article Text |
id | pubmed-10547612 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer US |
record_format | MEDLINE/PubMed |
spelling | pubmed-105476122023-10-05 Electrophysiological findings during re-do procedures after single-shot pulmonary vein isolation for atrial fibrillation with pulsed field ablation Magni, Federico Tancredi Scherr, Daniel Manninger, Martin Sohns, Christian Sommer, Philip Hovakimyan, Tatevik Blaauw, Yuri Mulder, Bart A. J Interv Card Electrophysiol Article BACKGROUND: Pulsed field ablation (PFA) is a novel ablation technology recently adopted in the treatment of atrial fibrillation (AF). Currently, little is known about the durability of PFA ablation lesions. METHODS: We investigated patients who underwent redo-ablation due to recurrent AF/atrial-flutter or tachycardia (AFL/AT) following PVI with PFA. We report electrophysiological findings and ablation strategy during redo-ablation. RESULTS: Of 447 patients undergoing index PVI with PFA, 14 patients (age: 61.9±10.8 years; 7 (50.0%) males; left atrial volume index (n=10): 39.4±14.6 mL/m(2)) were referred for redo-ablation. Initial indication was paroxysmal-AF in 7 patients, persistent-AF in 6 and long-standing-persistent-AF in one patient. Mean time-to-recurrence was 4.9±1.9 months. Three patients received additional posterior-wall-isolation during index PFA. Twelve (85.7%) patients suffered AF recurrence and 5/12 had concomitant AFL. In the remaining 2 patients, one had a (box-dependent) AFL, and one had an atypical AT. No patients had all PVs reconnected. Reconnection in zero, one, two or three PVs was found in 35.7%, 21.4%, 14.3%, and 28.6% of patients, respectively. All 7 patients with zero or one reconnection with AF recurrence received additional/repeat posterior-wall-isolation during re-ablation, while in the others, PVs were re-isolated. Patients with only AFL/AT had no reconnection of PVs, and the substrate was successfully ablated. CONCLUSIONS: Durable PVI (all PV’s isolated) was observed in over one-third of patients at re-do. The predominant recurrent arrhythmia following PVI-only was AF. Concomitant (35.7%) or isolated (14.3%) AFL/AT recurrence was observed in 50% of patients. Springer US 2023-05-17 2023 /pmc/articles/PMC10547612/ /pubmed/37195355 http://dx.doi.org/10.1007/s10840-023-01559-z Text en © The Author(s) 2023, corrected publication 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Magni, Federico Tancredi Scherr, Daniel Manninger, Martin Sohns, Christian Sommer, Philip Hovakimyan, Tatevik Blaauw, Yuri Mulder, Bart A. Electrophysiological findings during re-do procedures after single-shot pulmonary vein isolation for atrial fibrillation with pulsed field ablation |
title | Electrophysiological findings during re-do procedures after single-shot pulmonary vein isolation for atrial fibrillation with pulsed field ablation |
title_full | Electrophysiological findings during re-do procedures after single-shot pulmonary vein isolation for atrial fibrillation with pulsed field ablation |
title_fullStr | Electrophysiological findings during re-do procedures after single-shot pulmonary vein isolation for atrial fibrillation with pulsed field ablation |
title_full_unstemmed | Electrophysiological findings during re-do procedures after single-shot pulmonary vein isolation for atrial fibrillation with pulsed field ablation |
title_short | Electrophysiological findings during re-do procedures after single-shot pulmonary vein isolation for atrial fibrillation with pulsed field ablation |
title_sort | electrophysiological findings during re-do procedures after single-shot pulmonary vein isolation for atrial fibrillation with pulsed field ablation |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10547612/ https://www.ncbi.nlm.nih.gov/pubmed/37195355 http://dx.doi.org/10.1007/s10840-023-01559-z |
work_keys_str_mv | AT magnifedericotancredi electrophysiologicalfindingsduringredoproceduresaftersingleshotpulmonaryveinisolationforatrialfibrillationwithpulsedfieldablation AT scherrdaniel electrophysiologicalfindingsduringredoproceduresaftersingleshotpulmonaryveinisolationforatrialfibrillationwithpulsedfieldablation AT manningermartin electrophysiologicalfindingsduringredoproceduresaftersingleshotpulmonaryveinisolationforatrialfibrillationwithpulsedfieldablation AT sohnschristian electrophysiologicalfindingsduringredoproceduresaftersingleshotpulmonaryveinisolationforatrialfibrillationwithpulsedfieldablation AT sommerphilip electrophysiologicalfindingsduringredoproceduresaftersingleshotpulmonaryveinisolationforatrialfibrillationwithpulsedfieldablation AT hovakimyantatevik electrophysiologicalfindingsduringredoproceduresaftersingleshotpulmonaryveinisolationforatrialfibrillationwithpulsedfieldablation AT blaauwyuri electrophysiologicalfindingsduringredoproceduresaftersingleshotpulmonaryveinisolationforatrialfibrillationwithpulsedfieldablation AT mulderbarta electrophysiologicalfindingsduringredoproceduresaftersingleshotpulmonaryveinisolationforatrialfibrillationwithpulsedfieldablation |