Improved Thermal Sensitivity Using Virtual Monochromatic Imaging Derived from Photon Counting Detector CT Data Sets: Ex Vivo Results of CT-Guided Cryoablation in Porcine Liver
PURPOSE: To investigate differences in thermal sensitivity of virtual monoenergetic imaging (VMI) series generated from photon-counting detector (PCD) CT data sets, regarding their use to improve discrimination of the ablation zone during percutaneous cryoablation. MATERIALS AND METHODS: CT-guided c...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer US
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10547619/ https://www.ncbi.nlm.nih.gov/pubmed/37700006 http://dx.doi.org/10.1007/s00270-023-03546-3 |
Sumario: | PURPOSE: To investigate differences in thermal sensitivity of virtual monoenergetic imaging (VMI) series generated from photon-counting detector (PCD) CT data sets, regarding their use to improve discrimination of the ablation zone during percutaneous cryoablation. MATERIALS AND METHODS: CT-guided cryoablation was performed using an ex vivo model of porcine liver on a PCD-CT system. The ablation zone was imaged continuously for 8 min by acquiring a CT scan every 5 s. Tissue temperature was measured using fiberoptic temperature probes placed parallel to the cryoprobe. CT-values and noise were measured at the tip of the temperature probes on each scan and on VMI series from 40 to 130 keV. Correlation of CT-values and temperature was assessed using linear regression analyses. RESULTS: For the whole temperature range of [− 40, + 20] °C, we observed a linear correlation between CT-values and temperature in reference 70 keV images (R(2) = 0.60, p < 0.001) with a thermal sensitivity of 1.4(HU)/(°C). For the most dynamic range of [− 15, + 20] °C, the sensitivity increased to 2.4(HU)/(°C) (R(2) = 0.50, p < 0.001). Using VMI reconstructions, the thermal sensitivity increased from 1.4 (HU)/(°C) at 70 keV to 1.5, 1.7 and 2.0(HU)/(°C) at 60, 50 and 40 keV, respectively (range [− 40, + 20] °C). For [− 15, + 20]°C, the thermal sensitivity increased from 2.4(HU)/(°C) at 70 keV to 2.5, 2.6 and 2.7(HU)/(°C) at 60, 50 and 40 keV, respectively. Both CT-values and noise also increased with decreasing VMI keV-levels. CONCLUSION: During CT-guided cryoablation of porcine liver, low-keV VMI reconstructions derived from PCD-CT data sets exhibit improved thermal sensitivity being highest between + 20 and − 15 °C. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00270-023-03546-3. |
---|