Cargando…
Primary stability of implant placement and loading related to dental implant materials and designs: A literature review
A variety of implant placement and loading protocols are identified, ranging from immediate implant placement on the day of extraction to delayed placement for at least 6 months after complete healing. The method of assessment of implant placement and loading plays an important role in the implantat...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Association for Dental Sciences of the Republic of China
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10548003/ https://www.ncbi.nlm.nih.gov/pubmed/37799926 http://dx.doi.org/10.1016/j.jds.2023.06.010 |
_version_ | 1785115181046562816 |
---|---|
author | Huang, Yu-Che Huang, Yen-Chang Ding, Shinn-Jyh |
author_facet | Huang, Yu-Che Huang, Yen-Chang Ding, Shinn-Jyh |
author_sort | Huang, Yu-Che |
collection | PubMed |
description | A variety of implant placement and loading protocols are identified, ranging from immediate implant placement on the day of extraction to delayed placement for at least 6 months after complete healing. The method of assessment of implant placement and loading plays an important role in the implantation. The expected clinical outcomes depend largely on multiple factors, such as the macroscopic design of the implant, surgical technique, and the quality and quantity of local bone in contact with the implant, which would be described in detail. The purpose of this literature review was to explore the relationship between the factors influencing the implant placement stability and implant design. By understanding the original appearance of implant design and the stability requirements of implant placement, it is hoped that more research in the future can meet the needs of dentists and patients. |
format | Online Article Text |
id | pubmed-10548003 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Association for Dental Sciences of the Republic of China |
record_format | MEDLINE/PubMed |
spelling | pubmed-105480032023-10-05 Primary stability of implant placement and loading related to dental implant materials and designs: A literature review Huang, Yu-Che Huang, Yen-Chang Ding, Shinn-Jyh J Dent Sci Review Article A variety of implant placement and loading protocols are identified, ranging from immediate implant placement on the day of extraction to delayed placement for at least 6 months after complete healing. The method of assessment of implant placement and loading plays an important role in the implantation. The expected clinical outcomes depend largely on multiple factors, such as the macroscopic design of the implant, surgical technique, and the quality and quantity of local bone in contact with the implant, which would be described in detail. The purpose of this literature review was to explore the relationship between the factors influencing the implant placement stability and implant design. By understanding the original appearance of implant design and the stability requirements of implant placement, it is hoped that more research in the future can meet the needs of dentists and patients. Association for Dental Sciences of the Republic of China 2023-10 2023-06-25 /pmc/articles/PMC10548003/ /pubmed/37799926 http://dx.doi.org/10.1016/j.jds.2023.06.010 Text en © 2023 Association for Dental Sciences of the Republic of China. Publishing services by Elsevier B.V. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Review Article Huang, Yu-Che Huang, Yen-Chang Ding, Shinn-Jyh Primary stability of implant placement and loading related to dental implant materials and designs: A literature review |
title | Primary stability of implant placement and loading related to dental implant materials and designs: A literature review |
title_full | Primary stability of implant placement and loading related to dental implant materials and designs: A literature review |
title_fullStr | Primary stability of implant placement and loading related to dental implant materials and designs: A literature review |
title_full_unstemmed | Primary stability of implant placement and loading related to dental implant materials and designs: A literature review |
title_short | Primary stability of implant placement and loading related to dental implant materials and designs: A literature review |
title_sort | primary stability of implant placement and loading related to dental implant materials and designs: a literature review |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10548003/ https://www.ncbi.nlm.nih.gov/pubmed/37799926 http://dx.doi.org/10.1016/j.jds.2023.06.010 |
work_keys_str_mv | AT huangyuche primarystabilityofimplantplacementandloadingrelatedtodentalimplantmaterialsanddesignsaliteraturereview AT huangyenchang primarystabilityofimplantplacementandloadingrelatedtodentalimplantmaterialsanddesignsaliteraturereview AT dingshinnjyh primarystabilityofimplantplacementandloadingrelatedtodentalimplantmaterialsanddesignsaliteraturereview |