Cargando…
Assessment of mechanical characteristics of polyetheretherketone as orthodontic fixed lingual retainers
BACKGROUND/PURPOSE: Polyetheretherketone (PEEK) is known for its strength, flexibility, biocompatibility, and potential as a replacement for metals in dental appliances; however, uncertainty remains about the mechanical characteristics and dimensions of PEEK-made orthodontic fixed lingual retainers...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Association for Dental Sciences of the Republic of China
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10548050/ https://www.ncbi.nlm.nih.gov/pubmed/37799918 http://dx.doi.org/10.1016/j.jds.2023.05.026 |
_version_ | 1785115192006279168 |
---|---|
author | Win, Pyi Phyo Chen, Daniel De-Shing Sainbayar, Bolormaa Peng, Tzu-Yu Cheng, Johnson Hsin-Chung |
author_facet | Win, Pyi Phyo Chen, Daniel De-Shing Sainbayar, Bolormaa Peng, Tzu-Yu Cheng, Johnson Hsin-Chung |
author_sort | Win, Pyi Phyo |
collection | PubMed |
description | BACKGROUND/PURPOSE: Polyetheretherketone (PEEK) is known for its strength, flexibility, biocompatibility, and potential as a replacement for metals in dental appliances; however, uncertainty remains about the mechanical characteristics and dimensions of PEEK-made orthodontic fixed lingual retainers (FLRs). This study aimed to determine the optimal shape of PEEK-made orthodontic FLRs using the finite element method (FEM) and the three-point bending test (TPBT). MATERIALS AND METHODS: Seventy-five three-dimensional PEEK rod-shaped models were created, which included five thicknesses (0.4, 0.6, 0.8, 1.0, and 1.2 mm), five widths (0.7, 0.9, 1.1, 1.3, and 1.5 mm), and three cross-sectional shapes (rectangular, oval, and hemielliptical). A 0.9-mm (0.036-inch) stainless steel wire (SSW) was used as a control and the FEM was used to determine six optimal dimensions among the PEEK models. The selected models were then fabricated and subjected, along with the SSW, to the experimental TPBT to assess their mechanical responses against lingual and biting pressures. RESULTS: The FEM analysis revealed that Von Mises stresses on the PEEK models decreased with an increase in width and thickness. Six optimal shapes of PEEK models were chosen based on acceptable lingual and biting stresses as well as patient comfort compared to the SSW. Furthermore, PEEK models showed significantly lower deformation during the 3.1-mm deflection test than did the SSW, while no notable differences were observed among different sizes of PEEK models. The hemielliptical PEEK model with a thickness of 1.0 mm and width of 1.5 mm was found to be mechanically robust enough to withstand lingual forces, while none of the PEEK models, including the SSW, were able to resist biting forces. CONCLUSION: Within the limitations of this in vitro study, PEEK-made orthodontic FLRs with a hemielliptical cross-sectional shape and a thickness-to-width ratio of 1.0:1.5 would be suitable for use as orthodontic FLRs. |
format | Online Article Text |
id | pubmed-10548050 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Association for Dental Sciences of the Republic of China |
record_format | MEDLINE/PubMed |
spelling | pubmed-105480502023-10-05 Assessment of mechanical characteristics of polyetheretherketone as orthodontic fixed lingual retainers Win, Pyi Phyo Chen, Daniel De-Shing Sainbayar, Bolormaa Peng, Tzu-Yu Cheng, Johnson Hsin-Chung J Dent Sci Original Article BACKGROUND/PURPOSE: Polyetheretherketone (PEEK) is known for its strength, flexibility, biocompatibility, and potential as a replacement for metals in dental appliances; however, uncertainty remains about the mechanical characteristics and dimensions of PEEK-made orthodontic fixed lingual retainers (FLRs). This study aimed to determine the optimal shape of PEEK-made orthodontic FLRs using the finite element method (FEM) and the three-point bending test (TPBT). MATERIALS AND METHODS: Seventy-five three-dimensional PEEK rod-shaped models were created, which included five thicknesses (0.4, 0.6, 0.8, 1.0, and 1.2 mm), five widths (0.7, 0.9, 1.1, 1.3, and 1.5 mm), and three cross-sectional shapes (rectangular, oval, and hemielliptical). A 0.9-mm (0.036-inch) stainless steel wire (SSW) was used as a control and the FEM was used to determine six optimal dimensions among the PEEK models. The selected models were then fabricated and subjected, along with the SSW, to the experimental TPBT to assess their mechanical responses against lingual and biting pressures. RESULTS: The FEM analysis revealed that Von Mises stresses on the PEEK models decreased with an increase in width and thickness. Six optimal shapes of PEEK models were chosen based on acceptable lingual and biting stresses as well as patient comfort compared to the SSW. Furthermore, PEEK models showed significantly lower deformation during the 3.1-mm deflection test than did the SSW, while no notable differences were observed among different sizes of PEEK models. The hemielliptical PEEK model with a thickness of 1.0 mm and width of 1.5 mm was found to be mechanically robust enough to withstand lingual forces, while none of the PEEK models, including the SSW, were able to resist biting forces. CONCLUSION: Within the limitations of this in vitro study, PEEK-made orthodontic FLRs with a hemielliptical cross-sectional shape and a thickness-to-width ratio of 1.0:1.5 would be suitable for use as orthodontic FLRs. Association for Dental Sciences of the Republic of China 2023-10 2023-06-08 /pmc/articles/PMC10548050/ /pubmed/37799918 http://dx.doi.org/10.1016/j.jds.2023.05.026 Text en © 2023 Association for Dental Sciences of the Republic of China. Publishing services by Elsevier B.V. https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Original Article Win, Pyi Phyo Chen, Daniel De-Shing Sainbayar, Bolormaa Peng, Tzu-Yu Cheng, Johnson Hsin-Chung Assessment of mechanical characteristics of polyetheretherketone as orthodontic fixed lingual retainers |
title | Assessment of mechanical characteristics of polyetheretherketone as orthodontic fixed lingual retainers |
title_full | Assessment of mechanical characteristics of polyetheretherketone as orthodontic fixed lingual retainers |
title_fullStr | Assessment of mechanical characteristics of polyetheretherketone as orthodontic fixed lingual retainers |
title_full_unstemmed | Assessment of mechanical characteristics of polyetheretherketone as orthodontic fixed lingual retainers |
title_short | Assessment of mechanical characteristics of polyetheretherketone as orthodontic fixed lingual retainers |
title_sort | assessment of mechanical characteristics of polyetheretherketone as orthodontic fixed lingual retainers |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10548050/ https://www.ncbi.nlm.nih.gov/pubmed/37799918 http://dx.doi.org/10.1016/j.jds.2023.05.026 |
work_keys_str_mv | AT winpyiphyo assessmentofmechanicalcharacteristicsofpolyetheretherketoneasorthodonticfixedlingualretainers AT chendanieldeshing assessmentofmechanicalcharacteristicsofpolyetheretherketoneasorthodonticfixedlingualretainers AT sainbayarbolormaa assessmentofmechanicalcharacteristicsofpolyetheretherketoneasorthodonticfixedlingualretainers AT pengtzuyu assessmentofmechanicalcharacteristicsofpolyetheretherketoneasorthodonticfixedlingualretainers AT chengjohnsonhsinchung assessmentofmechanicalcharacteristicsofpolyetheretherketoneasorthodonticfixedlingualretainers |