Cargando…
Design and Application of an Acetabular Integrative Anatomic Plate: A Retrospective Study of 178 Cases with Complex Acetabular Fractures
OBJECTIVE: As conventional plates require repeated pre‐bending during surgery with poor matching, this study aimed to explore the design and application of an acetabular integrative anatomical plate (AIAP) via the lateral‐rectus approach (LRA) in fresh complex acetabular fractures for the good reduc...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley & Sons Australia, Ltd
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10549807/ https://www.ncbi.nlm.nih.gov/pubmed/37620863 http://dx.doi.org/10.1111/os.13817 |
_version_ | 1785115400215724032 |
---|---|
author | Fan, Shicai Mai, Qiguang Li, Tao Wang, Hua Yang, Cheng Huang, Hai Liao, Jianwen Zhang, Yingze |
author_facet | Fan, Shicai Mai, Qiguang Li, Tao Wang, Hua Yang, Cheng Huang, Hai Liao, Jianwen Zhang, Yingze |
author_sort | Fan, Shicai |
collection | PubMed |
description | OBJECTIVE: As conventional plates require repeated pre‐bending during surgery with poor matching, this study aimed to explore the design and application of an acetabular integrative anatomical plate (AIAP) via the lateral‐rectus approach (LRA) in fresh complex acetabular fractures for the good reduction and fixation. METHODS: We designed an AIAP based on the anatomical morphology of the Chinese people. From March 2016 to September 2021, 178 patients with fresh complex acetabular fractures treated with an AIAP via the LRA were retrospectively analyzed. All patients were treated by the LRA under general anesthesia in a supine position. The fragments were well reduced and fixed by AIAPs. The operation time and intraoperative blood loss were recorded. All patients underwent reexamination of pelvic X‐rays and CT scans and were followed up for over 1 year postoperatively. The reduction quality of fracture was evaluated according to the Matta criteria. The postoperative functional recovery was evaluated by modified Merle d'Aubigne‐Postel scoring system. Statistics were analyzed by SPSS 25.0 (SPSS Inc., Chicago, IL, USA). RESULTS: All 178 patients went through the operation successfully. The time from injury to operation ranged from 5 to 21 days (8.7 ± 2.6 days). The operation time ranged from 35 to 150 min (75 ± 29 min). The intraoperative blood loss was from 250 to 1400 ml (440 ± 153 ml). According to the Matta score, the fracture reduction was evaluated as excellent in 131 cases, good in 31 cases, and poor in 16 cases, with an overall excellent and good rate of 91%. Four patients suffered wound fat liquefaction and healed after fresh dressing. All patients were followed up for 1 to 5 years without wound infection. All fractures were healed. At the last follow‐up, the modified Merle d'Aubigne‐Postel score results were evaluated as excellent in 125 cases, good in 26 cases, and fair in 27 cases, with an overall excellent and good rate of 84.8%. Postoperative complications included six cases of traumatic arthritis of the hips and two cases of femoral head necrosis. CONCLUSION: The LRA with an AIAP can help expose, reduce, and fix anterior and posterior columns as well as the quadrilateral area of the acetabulum, which is capable of improving the reduction quality of complex acetabular fractures and shortening surgical time and blood loss, thus reaching a good clinical efficacy. |
format | Online Article Text |
id | pubmed-10549807 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | John Wiley & Sons Australia, Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-105498072023-10-05 Design and Application of an Acetabular Integrative Anatomic Plate: A Retrospective Study of 178 Cases with Complex Acetabular Fractures Fan, Shicai Mai, Qiguang Li, Tao Wang, Hua Yang, Cheng Huang, Hai Liao, Jianwen Zhang, Yingze Orthop Surg Clinical Articles OBJECTIVE: As conventional plates require repeated pre‐bending during surgery with poor matching, this study aimed to explore the design and application of an acetabular integrative anatomical plate (AIAP) via the lateral‐rectus approach (LRA) in fresh complex acetabular fractures for the good reduction and fixation. METHODS: We designed an AIAP based on the anatomical morphology of the Chinese people. From March 2016 to September 2021, 178 patients with fresh complex acetabular fractures treated with an AIAP via the LRA were retrospectively analyzed. All patients were treated by the LRA under general anesthesia in a supine position. The fragments were well reduced and fixed by AIAPs. The operation time and intraoperative blood loss were recorded. All patients underwent reexamination of pelvic X‐rays and CT scans and were followed up for over 1 year postoperatively. The reduction quality of fracture was evaluated according to the Matta criteria. The postoperative functional recovery was evaluated by modified Merle d'Aubigne‐Postel scoring system. Statistics were analyzed by SPSS 25.0 (SPSS Inc., Chicago, IL, USA). RESULTS: All 178 patients went through the operation successfully. The time from injury to operation ranged from 5 to 21 days (8.7 ± 2.6 days). The operation time ranged from 35 to 150 min (75 ± 29 min). The intraoperative blood loss was from 250 to 1400 ml (440 ± 153 ml). According to the Matta score, the fracture reduction was evaluated as excellent in 131 cases, good in 31 cases, and poor in 16 cases, with an overall excellent and good rate of 91%. Four patients suffered wound fat liquefaction and healed after fresh dressing. All patients were followed up for 1 to 5 years without wound infection. All fractures were healed. At the last follow‐up, the modified Merle d'Aubigne‐Postel score results were evaluated as excellent in 125 cases, good in 26 cases, and fair in 27 cases, with an overall excellent and good rate of 84.8%. Postoperative complications included six cases of traumatic arthritis of the hips and two cases of femoral head necrosis. CONCLUSION: The LRA with an AIAP can help expose, reduce, and fix anterior and posterior columns as well as the quadrilateral area of the acetabulum, which is capable of improving the reduction quality of complex acetabular fractures and shortening surgical time and blood loss, thus reaching a good clinical efficacy. John Wiley & Sons Australia, Ltd 2023-08-24 /pmc/articles/PMC10549807/ /pubmed/37620863 http://dx.doi.org/10.1111/os.13817 Text en © 2023 The Authors. Orthopaedic Surgery published by Tianjin Hospital and John Wiley & Sons Australia, Ltd. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Articles Fan, Shicai Mai, Qiguang Li, Tao Wang, Hua Yang, Cheng Huang, Hai Liao, Jianwen Zhang, Yingze Design and Application of an Acetabular Integrative Anatomic Plate: A Retrospective Study of 178 Cases with Complex Acetabular Fractures |
title | Design and Application of an Acetabular Integrative Anatomic Plate: A Retrospective Study of 178 Cases with Complex Acetabular Fractures |
title_full | Design and Application of an Acetabular Integrative Anatomic Plate: A Retrospective Study of 178 Cases with Complex Acetabular Fractures |
title_fullStr | Design and Application of an Acetabular Integrative Anatomic Plate: A Retrospective Study of 178 Cases with Complex Acetabular Fractures |
title_full_unstemmed | Design and Application of an Acetabular Integrative Anatomic Plate: A Retrospective Study of 178 Cases with Complex Acetabular Fractures |
title_short | Design and Application of an Acetabular Integrative Anatomic Plate: A Retrospective Study of 178 Cases with Complex Acetabular Fractures |
title_sort | design and application of an acetabular integrative anatomic plate: a retrospective study of 178 cases with complex acetabular fractures |
topic | Clinical Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10549807/ https://www.ncbi.nlm.nih.gov/pubmed/37620863 http://dx.doi.org/10.1111/os.13817 |
work_keys_str_mv | AT fanshicai designandapplicationofanacetabularintegrativeanatomicplatearetrospectivestudyof178caseswithcomplexacetabularfractures AT maiqiguang designandapplicationofanacetabularintegrativeanatomicplatearetrospectivestudyof178caseswithcomplexacetabularfractures AT litao designandapplicationofanacetabularintegrativeanatomicplatearetrospectivestudyof178caseswithcomplexacetabularfractures AT wanghua designandapplicationofanacetabularintegrativeanatomicplatearetrospectivestudyof178caseswithcomplexacetabularfractures AT yangcheng designandapplicationofanacetabularintegrativeanatomicplatearetrospectivestudyof178caseswithcomplexacetabularfractures AT huanghai designandapplicationofanacetabularintegrativeanatomicplatearetrospectivestudyof178caseswithcomplexacetabularfractures AT liaojianwen designandapplicationofanacetabularintegrativeanatomicplatearetrospectivestudyof178caseswithcomplexacetabularfractures AT zhangyingze designandapplicationofanacetabularintegrativeanatomicplatearetrospectivestudyof178caseswithcomplexacetabularfractures |