Cargando…

A novel approach for minimising anti-aliasing effects in EEG data acquisition

Electroencephalography (EEG) waves and other biological signals can be deciphered with a deeper understanding of the human body. The benefits of EEG are growing. EEG studies have expanded globally. Research on EEG covers data gathering, analysis, energy renewal, and more. EEG-gathering devices inclu...

Descripción completa

Detalles Bibliográficos
Autores principales: Brundavani, Putta, Vardhan, Dupakuntla Vishnu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: De Gruyter 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10549983/
https://www.ncbi.nlm.nih.gov/pubmed/37800116
http://dx.doi.org/10.1515/biol-2022-0664
_version_ 1785115436449267712
author Brundavani, Putta
Vardhan, Dupakuntla Vishnu
author_facet Brundavani, Putta
Vardhan, Dupakuntla Vishnu
author_sort Brundavani, Putta
collection PubMed
description Electroencephalography (EEG) waves and other biological signals can be deciphered with a deeper understanding of the human body. The benefits of EEG are growing. EEG studies have expanded globally. Research on EEG covers data gathering, analysis, energy renewal, and more. EEG-gathering devices include encoding, digital transfer, head sensor placement, and separate amplifiers. The EEG detects periodic noise. Head movement, sensor lines, and hair sweat produce low-frequency noise. Low-frequency noise alters EEG signals over time. Muscle actions and electromagnetic waves create high-frequency noise (especially in the facial and neck muscles). EEG shifts are saw-toothed by high-frequency noise. High- and low-frequency noises are usually lower and higher than human EEG, respectively. Lowering signal power above and below the testing level without altering the signs of interest lowers noise. Aliasing may affect low-frequency impacts in the original data because high-frequency noise is mirrored in the data. This work designed a non-binary Complementary metal oxide semiconductor (CMOS) Consecutive guesstimate register (CGR) reconfigurable analogue-to-digital converter (ADC) integrated with the instrumental amplifier. CGR ADC model comprises the bio-signal device monitoring for the EEG signals. This study focused on acquiring the EEG signals for amplification. The model uses the AC-coupled chopper stabilisation model with 1 A low power with a noise level of 1 A. The neural amplifier uses an optimised current technique to maximise the transconductance for a good noise efficiency factor. The simulation analysis estimates a bandwidth range of 0.05–120 Hz with a power consumption level of 0.271 µW. The computed noise level is observed as 1.1 µV(rms) and a gain of 45 dB. The comparative analysis of the proposed ADC model achieves the minimal energy consumption value of ∼12%, which is minimal than the nonlinear and switch-end capacitor. Also, the time consumed is ∼9% less than the nonlinear and switch-end Capacitor.18 nm CMOS technology is used to implement the proposed data acquisition system for low-power and density-optimised applications.
format Online
Article
Text
id pubmed-10549983
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher De Gruyter
record_format MEDLINE/PubMed
spelling pubmed-105499832023-10-05 A novel approach for minimising anti-aliasing effects in EEG data acquisition Brundavani, Putta Vardhan, Dupakuntla Vishnu Open Life Sci Research Article Electroencephalography (EEG) waves and other biological signals can be deciphered with a deeper understanding of the human body. The benefits of EEG are growing. EEG studies have expanded globally. Research on EEG covers data gathering, analysis, energy renewal, and more. EEG-gathering devices include encoding, digital transfer, head sensor placement, and separate amplifiers. The EEG detects periodic noise. Head movement, sensor lines, and hair sweat produce low-frequency noise. Low-frequency noise alters EEG signals over time. Muscle actions and electromagnetic waves create high-frequency noise (especially in the facial and neck muscles). EEG shifts are saw-toothed by high-frequency noise. High- and low-frequency noises are usually lower and higher than human EEG, respectively. Lowering signal power above and below the testing level without altering the signs of interest lowers noise. Aliasing may affect low-frequency impacts in the original data because high-frequency noise is mirrored in the data. This work designed a non-binary Complementary metal oxide semiconductor (CMOS) Consecutive guesstimate register (CGR) reconfigurable analogue-to-digital converter (ADC) integrated with the instrumental amplifier. CGR ADC model comprises the bio-signal device monitoring for the EEG signals. This study focused on acquiring the EEG signals for amplification. The model uses the AC-coupled chopper stabilisation model with 1 A low power with a noise level of 1 A. The neural amplifier uses an optimised current technique to maximise the transconductance for a good noise efficiency factor. The simulation analysis estimates a bandwidth range of 0.05–120 Hz with a power consumption level of 0.271 µW. The computed noise level is observed as 1.1 µV(rms) and a gain of 45 dB. The comparative analysis of the proposed ADC model achieves the minimal energy consumption value of ∼12%, which is minimal than the nonlinear and switch-end capacitor. Also, the time consumed is ∼9% less than the nonlinear and switch-end Capacitor.18 nm CMOS technology is used to implement the proposed data acquisition system for low-power and density-optimised applications. De Gruyter 2023-10-03 /pmc/articles/PMC10549983/ /pubmed/37800116 http://dx.doi.org/10.1515/biol-2022-0664 Text en © 2023 the author(s), published by De Gruyter https://creativecommons.org/licenses/by/4.0/This work is licensed under the Creative Commons Attribution 4.0 International License.
spellingShingle Research Article
Brundavani, Putta
Vardhan, Dupakuntla Vishnu
A novel approach for minimising anti-aliasing effects in EEG data acquisition
title A novel approach for minimising anti-aliasing effects in EEG data acquisition
title_full A novel approach for minimising anti-aliasing effects in EEG data acquisition
title_fullStr A novel approach for minimising anti-aliasing effects in EEG data acquisition
title_full_unstemmed A novel approach for minimising anti-aliasing effects in EEG data acquisition
title_short A novel approach for minimising anti-aliasing effects in EEG data acquisition
title_sort novel approach for minimising anti-aliasing effects in eeg data acquisition
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10549983/
https://www.ncbi.nlm.nih.gov/pubmed/37800116
http://dx.doi.org/10.1515/biol-2022-0664
work_keys_str_mv AT brundavaniputta anovelapproachforminimisingantialiasingeffectsineegdataacquisition
AT vardhandupakuntlavishnu anovelapproachforminimisingantialiasingeffectsineegdataacquisition
AT brundavaniputta novelapproachforminimisingantialiasingeffectsineegdataacquisition
AT vardhandupakuntlavishnu novelapproachforminimisingantialiasingeffectsineegdataacquisition