Cargando…

Safety, Effectiveness, and Hemodynamic Performance of the Bovine Pericardium Organic Valvular Bioprosthesis

OBJECTIVE: To assess actual data on the safety, effectiveness, and hemodynamic performance of Bovine Pericardium Organic Valvular Bioprosthesis (BVP). METHODS: The BIOPRO Trial is an observational, retrospective, non-comparative, non-randomized, and multicenter study. We collected data from 903 pati...

Descripción completa

Detalles Bibliográficos
Autores principales: Rösler, Álvaro Machado, Lucchese, Fernando Antonio, Pomerantzeff, Pablo Maria Alberto, Passos, Luiz Carlos Santana
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Sociedade Brasileira de Cirurgia Cardiovascular 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10549993/
https://www.ncbi.nlm.nih.gov/pubmed/37797247
http://dx.doi.org/10.21470/1678-9741-2023-0015
_version_ 1785115439029813248
author Rösler, Álvaro Machado
Lucchese, Fernando Antonio
Pomerantzeff, Pablo Maria Alberto
Passos, Luiz Carlos Santana
author_facet Rösler, Álvaro Machado
Lucchese, Fernando Antonio
Pomerantzeff, Pablo Maria Alberto
Passos, Luiz Carlos Santana
author_sort Rösler, Álvaro Machado
collection PubMed
description OBJECTIVE: To assess actual data on the safety, effectiveness, and hemodynamic performance of Bovine Pericardium Organic Valvular Bioprosthesis (BVP). METHODS: The BIOPRO Trial is an observational, retrospective, non-comparative, non-randomized, and multicenter study. We collected data from 903 patients with symptomatic, moderate, or severe valve disease who underwent BVP implants in the timeframe from 2013 to 2020 at three Brazilian institutions. Death, valve-related adverse events (AEs), functional recovery, and hemodynamic performance were evaluated at the hospital, at discharge, and six months and one year later. Primary analysis compared late (> 30 days after implant) linearized rates of valve-related AEs, such as thromboembolism, valve thrombosis, major hemorrhage, major paravalvular leak, and endocarditis, following objective performance criteria (OPC). Analysis was performed to include at least 400 valve-years for each valve position (aortic and mitral) for complete comparisons to OPC. Kaplan-Meier survival and major adverse cardiovascular and cerebrovascular event analyses were also performed. RESULTS: This retrospective study analyzed follow-up data collected from 903 patients (834.2 late patient-years) who have undergone surgery for 455 isolated aortic valve replacement (50.4%), 382 isolated mitral valve replacement (42.3%), and 66 combined valve replacement or other intervention (7.3%). The linearized rates of valve-related AEs were < 2 × OPC. One-year survival rates were 95.1% and 92.7% for aortic and mitral valve replacement, respectively. This study demonstrated an improvement in the New York Heart Association classification from baseline and hemodynamic performance within an expected range. CONCLUSION: According to this analysis, BVP meets world standards for safety and clinical efficacy.
format Online
Article
Text
id pubmed-10549993
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Sociedade Brasileira de Cirurgia Cardiovascular
record_format MEDLINE/PubMed
spelling pubmed-105499932023-10-05 Safety, Effectiveness, and Hemodynamic Performance of the Bovine Pericardium Organic Valvular Bioprosthesis Rösler, Álvaro Machado Lucchese, Fernando Antonio Pomerantzeff, Pablo Maria Alberto Passos, Luiz Carlos Santana Braz J Cardiovasc Surg Original Article OBJECTIVE: To assess actual data on the safety, effectiveness, and hemodynamic performance of Bovine Pericardium Organic Valvular Bioprosthesis (BVP). METHODS: The BIOPRO Trial is an observational, retrospective, non-comparative, non-randomized, and multicenter study. We collected data from 903 patients with symptomatic, moderate, or severe valve disease who underwent BVP implants in the timeframe from 2013 to 2020 at three Brazilian institutions. Death, valve-related adverse events (AEs), functional recovery, and hemodynamic performance were evaluated at the hospital, at discharge, and six months and one year later. Primary analysis compared late (> 30 days after implant) linearized rates of valve-related AEs, such as thromboembolism, valve thrombosis, major hemorrhage, major paravalvular leak, and endocarditis, following objective performance criteria (OPC). Analysis was performed to include at least 400 valve-years for each valve position (aortic and mitral) for complete comparisons to OPC. Kaplan-Meier survival and major adverse cardiovascular and cerebrovascular event analyses were also performed. RESULTS: This retrospective study analyzed follow-up data collected from 903 patients (834.2 late patient-years) who have undergone surgery for 455 isolated aortic valve replacement (50.4%), 382 isolated mitral valve replacement (42.3%), and 66 combined valve replacement or other intervention (7.3%). The linearized rates of valve-related AEs were < 2 × OPC. One-year survival rates were 95.1% and 92.7% for aortic and mitral valve replacement, respectively. This study demonstrated an improvement in the New York Heart Association classification from baseline and hemodynamic performance within an expected range. CONCLUSION: According to this analysis, BVP meets world standards for safety and clinical efficacy. Sociedade Brasileira de Cirurgia Cardiovascular 2023-08-07 /pmc/articles/PMC10549993/ /pubmed/37797247 http://dx.doi.org/10.21470/1678-9741-2023-0015 Text en https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Rösler, Álvaro Machado
Lucchese, Fernando Antonio
Pomerantzeff, Pablo Maria Alberto
Passos, Luiz Carlos Santana
Safety, Effectiveness, and Hemodynamic Performance of the Bovine Pericardium Organic Valvular Bioprosthesis
title Safety, Effectiveness, and Hemodynamic Performance of the Bovine Pericardium Organic Valvular Bioprosthesis
title_full Safety, Effectiveness, and Hemodynamic Performance of the Bovine Pericardium Organic Valvular Bioprosthesis
title_fullStr Safety, Effectiveness, and Hemodynamic Performance of the Bovine Pericardium Organic Valvular Bioprosthesis
title_full_unstemmed Safety, Effectiveness, and Hemodynamic Performance of the Bovine Pericardium Organic Valvular Bioprosthesis
title_short Safety, Effectiveness, and Hemodynamic Performance of the Bovine Pericardium Organic Valvular Bioprosthesis
title_sort safety, effectiveness, and hemodynamic performance of the bovine pericardium organic valvular bioprosthesis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10549993/
https://www.ncbi.nlm.nih.gov/pubmed/37797247
http://dx.doi.org/10.21470/1678-9741-2023-0015
work_keys_str_mv AT rosleralvaromachado safetyeffectivenessandhemodynamicperformanceofthebovinepericardiumorganicvalvularbioprosthesis
AT lucchesefernandoantonio safetyeffectivenessandhemodynamicperformanceofthebovinepericardiumorganicvalvularbioprosthesis
AT pomerantzeffpablomariaalberto safetyeffectivenessandhemodynamicperformanceofthebovinepericardiumorganicvalvularbioprosthesis
AT passosluizcarlossantana safetyeffectivenessandhemodynamicperformanceofthebovinepericardiumorganicvalvularbioprosthesis