Cargando…
Pregnancy and delivery after percutaneous embolization with a combination of microvascular plugs and hydrogel-coated coils for unilateral diffuse pulmonary arteriovenous malformations: a case report
BACKGROUND: Pulmonary arteriovenous malformations (PAVMs) are abnormal communications between the pulmonary arteries and veins; right-to-left shunts can cause hypoxaemia, emboli to systemic circulation, and brain abscesses. Cyanosis during pregnancy may increase the probability of premature birth or...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10551058/ https://www.ncbi.nlm.nih.gov/pubmed/37811152 http://dx.doi.org/10.1093/ehjcr/ytad468 |
_version_ | 1785115681576976384 |
---|---|
author | Ogino, Kayo Hayashi, Tomohiro Waki, Kenji Ohya, Masanobu |
author_facet | Ogino, Kayo Hayashi, Tomohiro Waki, Kenji Ohya, Masanobu |
author_sort | Ogino, Kayo |
collection | PubMed |
description | BACKGROUND: Pulmonary arteriovenous malformations (PAVMs) are abnormal communications between the pulmonary arteries and veins; right-to-left shunts can cause hypoxaemia, emboli to systemic circulation, and brain abscesses. Cyanosis during pregnancy may increase the probability of premature birth or spontaneous abortion and may increase maternal cardiac complications. CASE SUMMARY: We describe a case of a 24-year-old woman with diffuse multiple PAVMs localized to the left inferior lobe and chronic cyanosis. She had increased exertional fatigue and chronic headaches and was New York Heart Association class II, although her rest sitting peripheral oxygen saturation (SpO(2)) had remained unchanged at 83% over the past 20 years. She underwent percutaneous embolization with microvascular plugs and hydrogel-coated coils. A microvascular plug was placed as an anchor near the venous sac, followed by hydrogel-coated coil embolization of the proximal pulmonary artery. A total of six sessions of catheter intervention were performed. The embolization was successful, her hypoxaemia was relieved, and she was able to conceive and deliver. Three years have passed since the last session, and SpO(2) 97% has been maintained. DISCUSSION: In the treatment of complex PAVMs, the combination of microvascular plugs and hydrogel-coated coils resulted in shorter procedure time, lower risk of migration of the embolus to the pulmonary veins, and less recanalization and revascularization. Percutaneous embolization of PAVMs resulted in safe delivery for the mother and child. |
format | Online Article Text |
id | pubmed-10551058 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-105510582023-10-06 Pregnancy and delivery after percutaneous embolization with a combination of microvascular plugs and hydrogel-coated coils for unilateral diffuse pulmonary arteriovenous malformations: a case report Ogino, Kayo Hayashi, Tomohiro Waki, Kenji Ohya, Masanobu Eur Heart J Case Rep Case Report BACKGROUND: Pulmonary arteriovenous malformations (PAVMs) are abnormal communications between the pulmonary arteries and veins; right-to-left shunts can cause hypoxaemia, emboli to systemic circulation, and brain abscesses. Cyanosis during pregnancy may increase the probability of premature birth or spontaneous abortion and may increase maternal cardiac complications. CASE SUMMARY: We describe a case of a 24-year-old woman with diffuse multiple PAVMs localized to the left inferior lobe and chronic cyanosis. She had increased exertional fatigue and chronic headaches and was New York Heart Association class II, although her rest sitting peripheral oxygen saturation (SpO(2)) had remained unchanged at 83% over the past 20 years. She underwent percutaneous embolization with microvascular plugs and hydrogel-coated coils. A microvascular plug was placed as an anchor near the venous sac, followed by hydrogel-coated coil embolization of the proximal pulmonary artery. A total of six sessions of catheter intervention were performed. The embolization was successful, her hypoxaemia was relieved, and she was able to conceive and deliver. Three years have passed since the last session, and SpO(2) 97% has been maintained. DISCUSSION: In the treatment of complex PAVMs, the combination of microvascular plugs and hydrogel-coated coils resulted in shorter procedure time, lower risk of migration of the embolus to the pulmonary veins, and less recanalization and revascularization. Percutaneous embolization of PAVMs resulted in safe delivery for the mother and child. Oxford University Press 2023-09-21 /pmc/articles/PMC10551058/ /pubmed/37811152 http://dx.doi.org/10.1093/ehjcr/ytad468 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Case Report Ogino, Kayo Hayashi, Tomohiro Waki, Kenji Ohya, Masanobu Pregnancy and delivery after percutaneous embolization with a combination of microvascular plugs and hydrogel-coated coils for unilateral diffuse pulmonary arteriovenous malformations: a case report |
title | Pregnancy and delivery after percutaneous embolization with a combination of microvascular plugs and hydrogel-coated coils for unilateral diffuse pulmonary arteriovenous malformations: a case report |
title_full | Pregnancy and delivery after percutaneous embolization with a combination of microvascular plugs and hydrogel-coated coils for unilateral diffuse pulmonary arteriovenous malformations: a case report |
title_fullStr | Pregnancy and delivery after percutaneous embolization with a combination of microvascular plugs and hydrogel-coated coils for unilateral diffuse pulmonary arteriovenous malformations: a case report |
title_full_unstemmed | Pregnancy and delivery after percutaneous embolization with a combination of microvascular plugs and hydrogel-coated coils for unilateral diffuse pulmonary arteriovenous malformations: a case report |
title_short | Pregnancy and delivery after percutaneous embolization with a combination of microvascular plugs and hydrogel-coated coils for unilateral diffuse pulmonary arteriovenous malformations: a case report |
title_sort | pregnancy and delivery after percutaneous embolization with a combination of microvascular plugs and hydrogel-coated coils for unilateral diffuse pulmonary arteriovenous malformations: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10551058/ https://www.ncbi.nlm.nih.gov/pubmed/37811152 http://dx.doi.org/10.1093/ehjcr/ytad468 |
work_keys_str_mv | AT oginokayo pregnancyanddeliveryafterpercutaneousembolizationwithacombinationofmicrovascularplugsandhydrogelcoatedcoilsforunilateraldiffusepulmonaryarteriovenousmalformationsacasereport AT hayashitomohiro pregnancyanddeliveryafterpercutaneousembolizationwithacombinationofmicrovascularplugsandhydrogelcoatedcoilsforunilateraldiffusepulmonaryarteriovenousmalformationsacasereport AT wakikenji pregnancyanddeliveryafterpercutaneousembolizationwithacombinationofmicrovascularplugsandhydrogelcoatedcoilsforunilateraldiffusepulmonaryarteriovenousmalformationsacasereport AT ohyamasanobu pregnancyanddeliveryafterpercutaneousembolizationwithacombinationofmicrovascularplugsandhydrogelcoatedcoilsforunilateraldiffusepulmonaryarteriovenousmalformationsacasereport |