Cargando…

The effect of airtightness required in building energy conservation regulations on indoor and outdoor originated pollutants

The contradiction of indoor air quality (IAQ) and energy conservation by isolating the indoor environment from the outdoor through airtightness is one of the challenges of the building sector. The key issue is, what are the optimum airtightness limits that can ensure IAQ in naturally ventilated buil...

Descripción completa

Detalles Bibliográficos
Autores principales: Zahed, Fatemeh, Pardakhti, Alireza, Motlagh, Majid Shafiepour, Mohammad Kari, Behrouz, Tavakoli, Azadeh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10551552/
https://www.ncbi.nlm.nih.gov/pubmed/37810804
http://dx.doi.org/10.1016/j.heliyon.2023.e20378
_version_ 1785115792875978752
author Zahed, Fatemeh
Pardakhti, Alireza
Motlagh, Majid Shafiepour
Mohammad Kari, Behrouz
Tavakoli, Azadeh
author_facet Zahed, Fatemeh
Pardakhti, Alireza
Motlagh, Majid Shafiepour
Mohammad Kari, Behrouz
Tavakoli, Azadeh
author_sort Zahed, Fatemeh
collection PubMed
description The contradiction of indoor air quality (IAQ) and energy conservation by isolating the indoor environment from the outdoor through airtightness is one of the challenges of the building sector. The key issue is, what are the optimum airtightness limits that can ensure IAQ in naturally ventilated buildings, taking into account the paradoxical effect of house leakages on the infiltration of outdoor pollutants and accumulation of indoor-generated pollutants? For this purpose, the effect of different levels of airtightness required in energy-compliant, low-energy, and very low-energy buildings on the concentration of two pollutants with outdoor and indoor origin, PM2.5 and formaldehyde, respectively, were studied. This study used a multizone model, CONTAM(W), which was validated using measured data to study the distribution of selected pollutants in a typical relatively old dwelling, to investigate the situation in Iran. Subsequently, we conducted simulations based on different combinations of scenarios for airtightness, user behavior, source strength, and meteorological parameters. The results showed that increasing the airtightness from the baseline scenario (ACH50 = 11.11/h) to 3, 1.5, and 0.75 in closed window conditions reduced the PM2.5 by 15%, 38%, and 58%, respectively, and elevated formaldehyde by 23%, 77%, and 169%, correspondingly. Under normal outdoor PM2.5 pollution, indoor formaldehyde levels exceeded the permissible limit only in closed window conditions, and IAQ remained acceptable in other scenarios. However, there is no indication that IAQ can be ensured by any degree of airtightness under severe outdoor air pollution, demanding specific solutions, such as those proposed in this work.
format Online
Article
Text
id pubmed-10551552
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-105515522023-10-06 The effect of airtightness required in building energy conservation regulations on indoor and outdoor originated pollutants Zahed, Fatemeh Pardakhti, Alireza Motlagh, Majid Shafiepour Mohammad Kari, Behrouz Tavakoli, Azadeh Heliyon Research Article The contradiction of indoor air quality (IAQ) and energy conservation by isolating the indoor environment from the outdoor through airtightness is one of the challenges of the building sector. The key issue is, what are the optimum airtightness limits that can ensure IAQ in naturally ventilated buildings, taking into account the paradoxical effect of house leakages on the infiltration of outdoor pollutants and accumulation of indoor-generated pollutants? For this purpose, the effect of different levels of airtightness required in energy-compliant, low-energy, and very low-energy buildings on the concentration of two pollutants with outdoor and indoor origin, PM2.5 and formaldehyde, respectively, were studied. This study used a multizone model, CONTAM(W), which was validated using measured data to study the distribution of selected pollutants in a typical relatively old dwelling, to investigate the situation in Iran. Subsequently, we conducted simulations based on different combinations of scenarios for airtightness, user behavior, source strength, and meteorological parameters. The results showed that increasing the airtightness from the baseline scenario (ACH50 = 11.11/h) to 3, 1.5, and 0.75 in closed window conditions reduced the PM2.5 by 15%, 38%, and 58%, respectively, and elevated formaldehyde by 23%, 77%, and 169%, correspondingly. Under normal outdoor PM2.5 pollution, indoor formaldehyde levels exceeded the permissible limit only in closed window conditions, and IAQ remained acceptable in other scenarios. However, there is no indication that IAQ can be ensured by any degree of airtightness under severe outdoor air pollution, demanding specific solutions, such as those proposed in this work. Elsevier 2023-09-21 /pmc/articles/PMC10551552/ /pubmed/37810804 http://dx.doi.org/10.1016/j.heliyon.2023.e20378 Text en © 2023 Published by Elsevier Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Article
Zahed, Fatemeh
Pardakhti, Alireza
Motlagh, Majid Shafiepour
Mohammad Kari, Behrouz
Tavakoli, Azadeh
The effect of airtightness required in building energy conservation regulations on indoor and outdoor originated pollutants
title The effect of airtightness required in building energy conservation regulations on indoor and outdoor originated pollutants
title_full The effect of airtightness required in building energy conservation regulations on indoor and outdoor originated pollutants
title_fullStr The effect of airtightness required in building energy conservation regulations on indoor and outdoor originated pollutants
title_full_unstemmed The effect of airtightness required in building energy conservation regulations on indoor and outdoor originated pollutants
title_short The effect of airtightness required in building energy conservation regulations on indoor and outdoor originated pollutants
title_sort effect of airtightness required in building energy conservation regulations on indoor and outdoor originated pollutants
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10551552/
https://www.ncbi.nlm.nih.gov/pubmed/37810804
http://dx.doi.org/10.1016/j.heliyon.2023.e20378
work_keys_str_mv AT zahedfatemeh theeffectofairtightnessrequiredinbuildingenergyconservationregulationsonindoorandoutdoororiginatedpollutants
AT pardakhtialireza theeffectofairtightnessrequiredinbuildingenergyconservationregulationsonindoorandoutdoororiginatedpollutants
AT motlaghmajidshafiepour theeffectofairtightnessrequiredinbuildingenergyconservationregulationsonindoorandoutdoororiginatedpollutants
AT mohammadkaribehrouz theeffectofairtightnessrequiredinbuildingenergyconservationregulationsonindoorandoutdoororiginatedpollutants
AT tavakoliazadeh theeffectofairtightnessrequiredinbuildingenergyconservationregulationsonindoorandoutdoororiginatedpollutants
AT zahedfatemeh effectofairtightnessrequiredinbuildingenergyconservationregulationsonindoorandoutdoororiginatedpollutants
AT pardakhtialireza effectofairtightnessrequiredinbuildingenergyconservationregulationsonindoorandoutdoororiginatedpollutants
AT motlaghmajidshafiepour effectofairtightnessrequiredinbuildingenergyconservationregulationsonindoorandoutdoororiginatedpollutants
AT mohammadkaribehrouz effectofairtightnessrequiredinbuildingenergyconservationregulationsonindoorandoutdoororiginatedpollutants
AT tavakoliazadeh effectofairtightnessrequiredinbuildingenergyconservationregulationsonindoorandoutdoororiginatedpollutants