Cargando…

Long-term Follow-up Results of Femoral Revision Hip Arthroplasty Using Impaction Bone Grafting and Standard Cemented Polished Stem

BACKGROUND: To report the long-term clinical and radiologic results of impaction bone grafting and standard cemented polished stem for femoral revision arthroplasty in patients with extensive bone deficiency. METHODS: We retrospectively reviewed 47 hips that underwent femoral revision hip arthroplas...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Jin Sung, Kweon, Seok Hyun, Kang, Sung Ju, Jo, Yang Hun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Orthopaedic Association 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10551692/
https://www.ncbi.nlm.nih.gov/pubmed/37811512
http://dx.doi.org/10.4055/cios23052
_version_ 1785115826142052352
author Park, Jin Sung
Kweon, Seok Hyun
Kang, Sung Ju
Jo, Yang Hun
author_facet Park, Jin Sung
Kweon, Seok Hyun
Kang, Sung Ju
Jo, Yang Hun
author_sort Park, Jin Sung
collection PubMed
description BACKGROUND: To report the long-term clinical and radiologic results of impaction bone grafting and standard cemented polished stem for femoral revision arthroplasty in patients with extensive bone deficiency. METHODS: We retrospectively reviewed 47 hips that underwent femoral revision hip arthroplasty using an impaction-morselized allograft with a standard cemented polished stem. The average age at the time of revision hip arthroplasty was 55 years (range, 39–75 years). The modified Harris hip score (HHS) was used for clinical evaluation. The radiologic evaluation focused on stem subsidence, stem position, progressive radiolucent lines, bone remodeling, and the incorporation of allografts. RESULTS: The modified HHS improved from an average of 55.04 (range, 25–79.5) preoperatively to 90.1 (range, 81–93.2) at the last follow-up. The mean follow-up duration was 13.5 years (10.9–17.8 years). The radiographic analysis revealed stable stems. Femoral stems showed an average subsidence of 3.2 mm (range, 2–8 mm) in the cement mantle. However, there was no mechanical failure or subsidence of the cement mantle in the femurs. The stem position was neutral or varus less than 5°. No progressive radiolucent line or osteolysis was observed. Evidence of cortical and trabecular remodeling was observed in all cases. There were four cases of intraoperative cracks and four cases of distal femur splitting. CONCLUSIONS: Initial stem stability using impaction bone grafting and a standard cemented polished stem in femoral revision arthroplasty resulted in good outcome. Delicate impaction grafting techniques and intraoperative crack and splitting fixation are the points that need attention for successful long-term results.
format Online
Article
Text
id pubmed-10551692
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher The Korean Orthopaedic Association
record_format MEDLINE/PubMed
spelling pubmed-105516922023-10-06 Long-term Follow-up Results of Femoral Revision Hip Arthroplasty Using Impaction Bone Grafting and Standard Cemented Polished Stem Park, Jin Sung Kweon, Seok Hyun Kang, Sung Ju Jo, Yang Hun Clin Orthop Surg Original Article BACKGROUND: To report the long-term clinical and radiologic results of impaction bone grafting and standard cemented polished stem for femoral revision arthroplasty in patients with extensive bone deficiency. METHODS: We retrospectively reviewed 47 hips that underwent femoral revision hip arthroplasty using an impaction-morselized allograft with a standard cemented polished stem. The average age at the time of revision hip arthroplasty was 55 years (range, 39–75 years). The modified Harris hip score (HHS) was used for clinical evaluation. The radiologic evaluation focused on stem subsidence, stem position, progressive radiolucent lines, bone remodeling, and the incorporation of allografts. RESULTS: The modified HHS improved from an average of 55.04 (range, 25–79.5) preoperatively to 90.1 (range, 81–93.2) at the last follow-up. The mean follow-up duration was 13.5 years (10.9–17.8 years). The radiographic analysis revealed stable stems. Femoral stems showed an average subsidence of 3.2 mm (range, 2–8 mm) in the cement mantle. However, there was no mechanical failure or subsidence of the cement mantle in the femurs. The stem position was neutral or varus less than 5°. No progressive radiolucent line or osteolysis was observed. Evidence of cortical and trabecular remodeling was observed in all cases. There were four cases of intraoperative cracks and four cases of distal femur splitting. CONCLUSIONS: Initial stem stability using impaction bone grafting and a standard cemented polished stem in femoral revision arthroplasty resulted in good outcome. Delicate impaction grafting techniques and intraoperative crack and splitting fixation are the points that need attention for successful long-term results. The Korean Orthopaedic Association 2023-10 2023-09-15 /pmc/articles/PMC10551692/ /pubmed/37811512 http://dx.doi.org/10.4055/cios23052 Text en Copyright © 2023 by The Korean Orthopaedic Association https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Park, Jin Sung
Kweon, Seok Hyun
Kang, Sung Ju
Jo, Yang Hun
Long-term Follow-up Results of Femoral Revision Hip Arthroplasty Using Impaction Bone Grafting and Standard Cemented Polished Stem
title Long-term Follow-up Results of Femoral Revision Hip Arthroplasty Using Impaction Bone Grafting and Standard Cemented Polished Stem
title_full Long-term Follow-up Results of Femoral Revision Hip Arthroplasty Using Impaction Bone Grafting and Standard Cemented Polished Stem
title_fullStr Long-term Follow-up Results of Femoral Revision Hip Arthroplasty Using Impaction Bone Grafting and Standard Cemented Polished Stem
title_full_unstemmed Long-term Follow-up Results of Femoral Revision Hip Arthroplasty Using Impaction Bone Grafting and Standard Cemented Polished Stem
title_short Long-term Follow-up Results of Femoral Revision Hip Arthroplasty Using Impaction Bone Grafting and Standard Cemented Polished Stem
title_sort long-term follow-up results of femoral revision hip arthroplasty using impaction bone grafting and standard cemented polished stem
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10551692/
https://www.ncbi.nlm.nih.gov/pubmed/37811512
http://dx.doi.org/10.4055/cios23052
work_keys_str_mv AT parkjinsung longtermfollowupresultsoffemoralrevisionhiparthroplastyusingimpactionbonegraftingandstandardcementedpolishedstem
AT kweonseokhyun longtermfollowupresultsoffemoralrevisionhiparthroplastyusingimpactionbonegraftingandstandardcementedpolishedstem
AT kangsungju longtermfollowupresultsoffemoralrevisionhiparthroplastyusingimpactionbonegraftingandstandardcementedpolishedstem
AT joyanghun longtermfollowupresultsoffemoralrevisionhiparthroplastyusingimpactionbonegraftingandstandardcementedpolishedstem