Cargando…

Effect of Saturation Pulse Duration and Power on pH-weighted Amide Proton Transfer Imaging: A Phantom Study

Purpose: Amide proton transfer (APT) imaging may detect changes in tissues’ pH based on the chemical exchange saturation transfer (CEST) phenomenon, and thus it may be useful for identifying the penumbra in ischemic stroke patients. We investigated the effect of saturation pulse duration and power o...

Descripción completa

Detalles Bibliográficos
Autores principales: Tokunaga, Chiaki, Wada, Tatsuhiro, Togao, Osamu, Yamashita, Yasuo, Kobayashi, Kouji, Kato, Toyoyuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Japanese Society for Magnetic Resonance in Medicine 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10552662/
https://www.ncbi.nlm.nih.gov/pubmed/36047248
http://dx.doi.org/10.2463/mrms.mp.2021-0109
_version_ 1785116006786531328
author Tokunaga, Chiaki
Wada, Tatsuhiro
Togao, Osamu
Yamashita, Yasuo
Kobayashi, Kouji
Kato, Toyoyuki
author_facet Tokunaga, Chiaki
Wada, Tatsuhiro
Togao, Osamu
Yamashita, Yasuo
Kobayashi, Kouji
Kato, Toyoyuki
author_sort Tokunaga, Chiaki
collection PubMed
description Purpose: Amide proton transfer (APT) imaging may detect changes in tissues’ pH based on the chemical exchange saturation transfer (CEST) phenomenon, and thus it may be useful for identifying the penumbra in ischemic stroke patients. We investigated the effect of saturation pulse duration and power on the APT effect in phantoms with different pH values. Methods: Five samples were prepared from a 1:10 solution of egg-white albumin in phosphate-buffered saline at pH 6.53–7.65. The APT signal intensity (SI) was defined as asymmetry of the magnetization transfer ratio at 3.5 ppm. We measured the APT SIs in the egg-white albumin samples of different pH values with saturation pulse durations of 0.5, 1.0, 2.0, and 3.0 sec and saturation pulse powers of 0.5, 1.5, and 2.5 μT. The relative change in the APT SI in relation to the saturation duration and power at different pH values was defined as follows: (APT SI (each saturation pulse) − APT SI (shortest or weakest pulse))/APT SI(shortest or weakest pulse). The dependence of the APT SI on pH and the relative change in the APT SI were calculated as the slope of the linear regression. Results: The lower the pH, the larger the relative change in the APT SI, due to the change in saturation pulse duration and power. The APT SI was highly correlated with the pH at all saturation pulse durations and powers. Conclusion: The influence of saturation duration and power on the APT effect was greater at lower pH than higher pH. The combination of saturation pulse ≥ 1.0 s and power ≥ 1.5 μT was useful for the sensitive detection of changes in APT effects in the egg-white albumin samples with different pH values.
format Online
Article
Text
id pubmed-10552662
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Japanese Society for Magnetic Resonance in Medicine
record_format MEDLINE/PubMed
spelling pubmed-105526622023-10-06 Effect of Saturation Pulse Duration and Power on pH-weighted Amide Proton Transfer Imaging: A Phantom Study Tokunaga, Chiaki Wada, Tatsuhiro Togao, Osamu Yamashita, Yasuo Kobayashi, Kouji Kato, Toyoyuki Magn Reson Med Sci Major Paper Purpose: Amide proton transfer (APT) imaging may detect changes in tissues’ pH based on the chemical exchange saturation transfer (CEST) phenomenon, and thus it may be useful for identifying the penumbra in ischemic stroke patients. We investigated the effect of saturation pulse duration and power on the APT effect in phantoms with different pH values. Methods: Five samples were prepared from a 1:10 solution of egg-white albumin in phosphate-buffered saline at pH 6.53–7.65. The APT signal intensity (SI) was defined as asymmetry of the magnetization transfer ratio at 3.5 ppm. We measured the APT SIs in the egg-white albumin samples of different pH values with saturation pulse durations of 0.5, 1.0, 2.0, and 3.0 sec and saturation pulse powers of 0.5, 1.5, and 2.5 μT. The relative change in the APT SI in relation to the saturation duration and power at different pH values was defined as follows: (APT SI (each saturation pulse) − APT SI (shortest or weakest pulse))/APT SI(shortest or weakest pulse). The dependence of the APT SI on pH and the relative change in the APT SI were calculated as the slope of the linear regression. Results: The lower the pH, the larger the relative change in the APT SI, due to the change in saturation pulse duration and power. The APT SI was highly correlated with the pH at all saturation pulse durations and powers. Conclusion: The influence of saturation duration and power on the APT effect was greater at lower pH than higher pH. The combination of saturation pulse ≥ 1.0 s and power ≥ 1.5 μT was useful for the sensitive detection of changes in APT effects in the egg-white albumin samples with different pH values. Japanese Society for Magnetic Resonance in Medicine 2022-09-01 /pmc/articles/PMC10552662/ /pubmed/36047248 http://dx.doi.org/10.2463/mrms.mp.2021-0109 Text en ©2022 Japanese Society for Magnetic Resonance in Medicine https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/)
spellingShingle Major Paper
Tokunaga, Chiaki
Wada, Tatsuhiro
Togao, Osamu
Yamashita, Yasuo
Kobayashi, Kouji
Kato, Toyoyuki
Effect of Saturation Pulse Duration and Power on pH-weighted Amide Proton Transfer Imaging: A Phantom Study
title Effect of Saturation Pulse Duration and Power on pH-weighted Amide Proton Transfer Imaging: A Phantom Study
title_full Effect of Saturation Pulse Duration and Power on pH-weighted Amide Proton Transfer Imaging: A Phantom Study
title_fullStr Effect of Saturation Pulse Duration and Power on pH-weighted Amide Proton Transfer Imaging: A Phantom Study
title_full_unstemmed Effect of Saturation Pulse Duration and Power on pH-weighted Amide Proton Transfer Imaging: A Phantom Study
title_short Effect of Saturation Pulse Duration and Power on pH-weighted Amide Proton Transfer Imaging: A Phantom Study
title_sort effect of saturation pulse duration and power on ph-weighted amide proton transfer imaging: a phantom study
topic Major Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10552662/
https://www.ncbi.nlm.nih.gov/pubmed/36047248
http://dx.doi.org/10.2463/mrms.mp.2021-0109
work_keys_str_mv AT tokunagachiaki effectofsaturationpulsedurationandpoweronphweightedamideprotontransferimagingaphantomstudy
AT wadatatsuhiro effectofsaturationpulsedurationandpoweronphweightedamideprotontransferimagingaphantomstudy
AT togaoosamu effectofsaturationpulsedurationandpoweronphweightedamideprotontransferimagingaphantomstudy
AT yamashitayasuo effectofsaturationpulsedurationandpoweronphweightedamideprotontransferimagingaphantomstudy
AT kobayashikouji effectofsaturationpulsedurationandpoweronphweightedamideprotontransferimagingaphantomstudy
AT katotoyoyuki effectofsaturationpulsedurationandpoweronphweightedamideprotontransferimagingaphantomstudy