Cargando…
Effect of Saturation Pulse Duration and Power on pH-weighted Amide Proton Transfer Imaging: A Phantom Study
Purpose: Amide proton transfer (APT) imaging may detect changes in tissues’ pH based on the chemical exchange saturation transfer (CEST) phenomenon, and thus it may be useful for identifying the penumbra in ischemic stroke patients. We investigated the effect of saturation pulse duration and power o...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Japanese Society for Magnetic Resonance in Medicine
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10552662/ https://www.ncbi.nlm.nih.gov/pubmed/36047248 http://dx.doi.org/10.2463/mrms.mp.2021-0109 |
_version_ | 1785116006786531328 |
---|---|
author | Tokunaga, Chiaki Wada, Tatsuhiro Togao, Osamu Yamashita, Yasuo Kobayashi, Kouji Kato, Toyoyuki |
author_facet | Tokunaga, Chiaki Wada, Tatsuhiro Togao, Osamu Yamashita, Yasuo Kobayashi, Kouji Kato, Toyoyuki |
author_sort | Tokunaga, Chiaki |
collection | PubMed |
description | Purpose: Amide proton transfer (APT) imaging may detect changes in tissues’ pH based on the chemical exchange saturation transfer (CEST) phenomenon, and thus it may be useful for identifying the penumbra in ischemic stroke patients. We investigated the effect of saturation pulse duration and power on the APT effect in phantoms with different pH values. Methods: Five samples were prepared from a 1:10 solution of egg-white albumin in phosphate-buffered saline at pH 6.53–7.65. The APT signal intensity (SI) was defined as asymmetry of the magnetization transfer ratio at 3.5 ppm. We measured the APT SIs in the egg-white albumin samples of different pH values with saturation pulse durations of 0.5, 1.0, 2.0, and 3.0 sec and saturation pulse powers of 0.5, 1.5, and 2.5 μT. The relative change in the APT SI in relation to the saturation duration and power at different pH values was defined as follows: (APT SI (each saturation pulse) − APT SI (shortest or weakest pulse))/APT SI(shortest or weakest pulse). The dependence of the APT SI on pH and the relative change in the APT SI were calculated as the slope of the linear regression. Results: The lower the pH, the larger the relative change in the APT SI, due to the change in saturation pulse duration and power. The APT SI was highly correlated with the pH at all saturation pulse durations and powers. Conclusion: The influence of saturation duration and power on the APT effect was greater at lower pH than higher pH. The combination of saturation pulse ≥ 1.0 s and power ≥ 1.5 μT was useful for the sensitive detection of changes in APT effects in the egg-white albumin samples with different pH values. |
format | Online Article Text |
id | pubmed-10552662 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Japanese Society for Magnetic Resonance in Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-105526622023-10-06 Effect of Saturation Pulse Duration and Power on pH-weighted Amide Proton Transfer Imaging: A Phantom Study Tokunaga, Chiaki Wada, Tatsuhiro Togao, Osamu Yamashita, Yasuo Kobayashi, Kouji Kato, Toyoyuki Magn Reson Med Sci Major Paper Purpose: Amide proton transfer (APT) imaging may detect changes in tissues’ pH based on the chemical exchange saturation transfer (CEST) phenomenon, and thus it may be useful for identifying the penumbra in ischemic stroke patients. We investigated the effect of saturation pulse duration and power on the APT effect in phantoms with different pH values. Methods: Five samples were prepared from a 1:10 solution of egg-white albumin in phosphate-buffered saline at pH 6.53–7.65. The APT signal intensity (SI) was defined as asymmetry of the magnetization transfer ratio at 3.5 ppm. We measured the APT SIs in the egg-white albumin samples of different pH values with saturation pulse durations of 0.5, 1.0, 2.0, and 3.0 sec and saturation pulse powers of 0.5, 1.5, and 2.5 μT. The relative change in the APT SI in relation to the saturation duration and power at different pH values was defined as follows: (APT SI (each saturation pulse) − APT SI (shortest or weakest pulse))/APT SI(shortest or weakest pulse). The dependence of the APT SI on pH and the relative change in the APT SI were calculated as the slope of the linear regression. Results: The lower the pH, the larger the relative change in the APT SI, due to the change in saturation pulse duration and power. The APT SI was highly correlated with the pH at all saturation pulse durations and powers. Conclusion: The influence of saturation duration and power on the APT effect was greater at lower pH than higher pH. The combination of saturation pulse ≥ 1.0 s and power ≥ 1.5 μT was useful for the sensitive detection of changes in APT effects in the egg-white albumin samples with different pH values. Japanese Society for Magnetic Resonance in Medicine 2022-09-01 /pmc/articles/PMC10552662/ /pubmed/36047248 http://dx.doi.org/10.2463/mrms.mp.2021-0109 Text en ©2022 Japanese Society for Magnetic Resonance in Medicine https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) |
spellingShingle | Major Paper Tokunaga, Chiaki Wada, Tatsuhiro Togao, Osamu Yamashita, Yasuo Kobayashi, Kouji Kato, Toyoyuki Effect of Saturation Pulse Duration and Power on pH-weighted Amide Proton Transfer Imaging: A Phantom Study |
title | Effect of Saturation Pulse Duration and Power on pH-weighted Amide Proton Transfer Imaging: A Phantom Study |
title_full | Effect of Saturation Pulse Duration and Power on pH-weighted Amide Proton Transfer Imaging: A Phantom Study |
title_fullStr | Effect of Saturation Pulse Duration and Power on pH-weighted Amide Proton Transfer Imaging: A Phantom Study |
title_full_unstemmed | Effect of Saturation Pulse Duration and Power on pH-weighted Amide Proton Transfer Imaging: A Phantom Study |
title_short | Effect of Saturation Pulse Duration and Power on pH-weighted Amide Proton Transfer Imaging: A Phantom Study |
title_sort | effect of saturation pulse duration and power on ph-weighted amide proton transfer imaging: a phantom study |
topic | Major Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10552662/ https://www.ncbi.nlm.nih.gov/pubmed/36047248 http://dx.doi.org/10.2463/mrms.mp.2021-0109 |
work_keys_str_mv | AT tokunagachiaki effectofsaturationpulsedurationandpoweronphweightedamideprotontransferimagingaphantomstudy AT wadatatsuhiro effectofsaturationpulsedurationandpoweronphweightedamideprotontransferimagingaphantomstudy AT togaoosamu effectofsaturationpulsedurationandpoweronphweightedamideprotontransferimagingaphantomstudy AT yamashitayasuo effectofsaturationpulsedurationandpoweronphweightedamideprotontransferimagingaphantomstudy AT kobayashikouji effectofsaturationpulsedurationandpoweronphweightedamideprotontransferimagingaphantomstudy AT katotoyoyuki effectofsaturationpulsedurationandpoweronphweightedamideprotontransferimagingaphantomstudy |