Cargando…

Clips closure versus endoloop ligation in laparoscopic appendectomy: a systematic review and meta-analysis of comparative studies

INTRODUCTION: Appendiceal stump closure (ASC) is a key step in performing laparoscopic appendicectomy. Currently, there is no gold standard method to achieve this goal. The ideal method should be safe, easily available, and have a short learning curve. Out of all those appendiceal stump closure meth...

Descripción completa

Detalles Bibliográficos
Autores principales: Poon, Samuel Ho Ting, Law, Sui Yuen, Lai, Alex Ting Yeung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10553101/
https://www.ncbi.nlm.nih.gov/pubmed/37811063
http://dx.doi.org/10.1097/MS9.0000000000001260
_version_ 1785116093917954048
author Poon, Samuel Ho Ting
Law, Sui Yuen
Lai, Alex Ting Yeung
author_facet Poon, Samuel Ho Ting
Law, Sui Yuen
Lai, Alex Ting Yeung
author_sort Poon, Samuel Ho Ting
collection PubMed
description INTRODUCTION: Appendiceal stump closure (ASC) is a key step in performing laparoscopic appendicectomy. Currently, there is no gold standard method to achieve this goal. The ideal method should be safe, easily available, and have a short learning curve. Out of all those appendiceal stump closure methods, the use of hem-o-Lok demonstrates its feasibility in replacing the traditionally used endoloop. In this systematic review and meta-analysis, the authors aim to review the currently available evidence addressing the topic of interest. METHOD: The PubMed and Embase databases were searched with the paired search terms appendicitis, clip, and endoloop by two authors separately. The quality of the randomized controlled trials was assessed with the Cochrane risk of bias tool, and the quality of the observational studies was assessed with the Newcastle-Ottawa scale. Meta-analysis was conducted with Cochrane Review Manager version 5.4. RESULT: Eighteen studies were included for quantitative analysis. The appendiceal stump closure time was shortened by 2 min 7 s using a hem-o-lok with 95% CI 1 min 48 s–2 min 26 s, p less than 0.00001. The pooled results of 6 randomized controlled trials demonstrated a statistically significant reduction in operative time of 5.15 min from adopting the hem-o-lok approach (p=0.001, 95% CI −2.05 to −8.24 min). Both endoloop and hem-o-lok demonstrated a comparable postoperative hospital stay and infective complication profile. CONCLUSION: The application of Hem-o-Lok demonstrates a comparable to endoloop ligation in terms of operative time and a potential benefit on the complication. When considering financial and technical aspects, it serves as an alternative to endoloop.
format Online
Article
Text
id pubmed-10553101
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-105531012023-10-06 Clips closure versus endoloop ligation in laparoscopic appendectomy: a systematic review and meta-analysis of comparative studies Poon, Samuel Ho Ting Law, Sui Yuen Lai, Alex Ting Yeung Ann Med Surg (Lond) Reviews INTRODUCTION: Appendiceal stump closure (ASC) is a key step in performing laparoscopic appendicectomy. Currently, there is no gold standard method to achieve this goal. The ideal method should be safe, easily available, and have a short learning curve. Out of all those appendiceal stump closure methods, the use of hem-o-Lok demonstrates its feasibility in replacing the traditionally used endoloop. In this systematic review and meta-analysis, the authors aim to review the currently available evidence addressing the topic of interest. METHOD: The PubMed and Embase databases were searched with the paired search terms appendicitis, clip, and endoloop by two authors separately. The quality of the randomized controlled trials was assessed with the Cochrane risk of bias tool, and the quality of the observational studies was assessed with the Newcastle-Ottawa scale. Meta-analysis was conducted with Cochrane Review Manager version 5.4. RESULT: Eighteen studies were included for quantitative analysis. The appendiceal stump closure time was shortened by 2 min 7 s using a hem-o-lok with 95% CI 1 min 48 s–2 min 26 s, p less than 0.00001. The pooled results of 6 randomized controlled trials demonstrated a statistically significant reduction in operative time of 5.15 min from adopting the hem-o-lok approach (p=0.001, 95% CI −2.05 to −8.24 min). Both endoloop and hem-o-lok demonstrated a comparable postoperative hospital stay and infective complication profile. CONCLUSION: The application of Hem-o-Lok demonstrates a comparable to endoloop ligation in terms of operative time and a potential benefit on the complication. When considering financial and technical aspects, it serves as an alternative to endoloop. Lippincott Williams & Wilkins 2023-09-06 /pmc/articles/PMC10553101/ /pubmed/37811063 http://dx.doi.org/10.1097/MS9.0000000000001260 Text en Copyright © 2023 The Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-sa/4.0/This is an open access article distributed under the Creative Commons Attribution-ShareAlike License 4.0 (https://creativecommons.org/licenses/by-sa/4.0/) , which allows others to remix, tweak, and build upon the work, even for commercial purposes, as long as the author is credited and the new creations are licensed under the identical terms. http://creativecommons.org/licenses/by-sa/4.0/ (https://creativecommons.org/licenses/by-sa/4.0/)
spellingShingle Reviews
Poon, Samuel Ho Ting
Law, Sui Yuen
Lai, Alex Ting Yeung
Clips closure versus endoloop ligation in laparoscopic appendectomy: a systematic review and meta-analysis of comparative studies
title Clips closure versus endoloop ligation in laparoscopic appendectomy: a systematic review and meta-analysis of comparative studies
title_full Clips closure versus endoloop ligation in laparoscopic appendectomy: a systematic review and meta-analysis of comparative studies
title_fullStr Clips closure versus endoloop ligation in laparoscopic appendectomy: a systematic review and meta-analysis of comparative studies
title_full_unstemmed Clips closure versus endoloop ligation in laparoscopic appendectomy: a systematic review and meta-analysis of comparative studies
title_short Clips closure versus endoloop ligation in laparoscopic appendectomy: a systematic review and meta-analysis of comparative studies
title_sort clips closure versus endoloop ligation in laparoscopic appendectomy: a systematic review and meta-analysis of comparative studies
topic Reviews
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10553101/
https://www.ncbi.nlm.nih.gov/pubmed/37811063
http://dx.doi.org/10.1097/MS9.0000000000001260
work_keys_str_mv AT poonsamuelhoting clipsclosureversusendoloopligationinlaparoscopicappendectomyasystematicreviewandmetaanalysisofcomparativestudies
AT lawsuiyuen clipsclosureversusendoloopligationinlaparoscopicappendectomyasystematicreviewandmetaanalysisofcomparativestudies
AT laialextingyeung clipsclosureversusendoloopligationinlaparoscopicappendectomyasystematicreviewandmetaanalysisofcomparativestudies