FRI495 Analytical Validation Of An Inductively Coupled Plasma Mass Spectrometry Method For Measuring Iodine Content In Breast Milk
Disclosure: J. Li: None. L. Lee: None. F. Wang: None. C. Yang: None. C. Huang: None. Background: Adequate iodine status in lactating women is defined by a maternal median urinary iodine concentration above 100 μg/L. However, the current standard does not account for the secretion of iodine into brea...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10555403/ http://dx.doi.org/10.1210/jendso/bvad114.1841 |
_version_ | 1785116649198714880 |
---|---|
author | Li, Jia-Zhen Lee, Lin-Hsuan Wang, Fan-Fen Yang, Chen-Chang Jui Huang, Chun |
author_facet | Li, Jia-Zhen Lee, Lin-Hsuan Wang, Fan-Fen Yang, Chen-Chang Jui Huang, Chun |
author_sort | Li, Jia-Zhen |
collection | PubMed |
description | Disclosure: J. Li: None. L. Lee: None. F. Wang: None. C. Yang: None. C. Huang: None. Background: Adequate iodine status in lactating women is defined by a maternal median urinary iodine concentration above 100 μg/L. However, the current standard does not account for the secretion of iodine into breastmilk and could not truly reflect the amount of iodine delivered to the infants. Measuring breastmilk median iodine concentration (BMIC) is of crucial importance but the method to measure BMIC has not been developed and validated in Taiwan. Method: We adopted the ammonia dilution method without prior sample digestion to measure BMIC by inductively coupled plasma mass spectrometry (ICP-MS). Samples and iodine calibrators were prepared into an aqueous solution containing Triton X-100, 0.5% ammonia solution and tellurium ((128)Te) as the internal standard. Precision, accuracy, serial dilution, and recovery tests were performed for method validation. Results: The intra-assay and inter-assay coefficient of variation for the four human breast milk samples with different iodine concentrations ranged from 3.2% to 4.7% and 2.3% to 5.5%, respectively. The standard NIST 1549 milk powder was prepared into three different concentrations of 50 μg/L, 100 μg/L and 200 μg/L to assess accuracy and the biases were <5%. A recovery of 95-105% was achieved for four human breast milk samples spiked with sodium iodide solution. The serial dilution test confirmed linearity up to 500 μg/L. The limit for detection and quantification was 0.73 μg/L and 2.19 μg/L, respectively. Conclusion: The results of the current study confirmed that this ICP-MS method is accurate and reliable in measuring BMIC. Presentation: Friday, June 16, 2023 |
format | Online Article Text |
id | pubmed-10555403 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-105554032023-10-06 FRI495 Analytical Validation Of An Inductively Coupled Plasma Mass Spectrometry Method For Measuring Iodine Content In Breast Milk Li, Jia-Zhen Lee, Lin-Hsuan Wang, Fan-Fen Yang, Chen-Chang Jui Huang, Chun J Endocr Soc Thyroid Disclosure: J. Li: None. L. Lee: None. F. Wang: None. C. Yang: None. C. Huang: None. Background: Adequate iodine status in lactating women is defined by a maternal median urinary iodine concentration above 100 μg/L. However, the current standard does not account for the secretion of iodine into breastmilk and could not truly reflect the amount of iodine delivered to the infants. Measuring breastmilk median iodine concentration (BMIC) is of crucial importance but the method to measure BMIC has not been developed and validated in Taiwan. Method: We adopted the ammonia dilution method without prior sample digestion to measure BMIC by inductively coupled plasma mass spectrometry (ICP-MS). Samples and iodine calibrators were prepared into an aqueous solution containing Triton X-100, 0.5% ammonia solution and tellurium ((128)Te) as the internal standard. Precision, accuracy, serial dilution, and recovery tests were performed for method validation. Results: The intra-assay and inter-assay coefficient of variation for the four human breast milk samples with different iodine concentrations ranged from 3.2% to 4.7% and 2.3% to 5.5%, respectively. The standard NIST 1549 milk powder was prepared into three different concentrations of 50 μg/L, 100 μg/L and 200 μg/L to assess accuracy and the biases were <5%. A recovery of 95-105% was achieved for four human breast milk samples spiked with sodium iodide solution. The serial dilution test confirmed linearity up to 500 μg/L. The limit for detection and quantification was 0.73 μg/L and 2.19 μg/L, respectively. Conclusion: The results of the current study confirmed that this ICP-MS method is accurate and reliable in measuring BMIC. Presentation: Friday, June 16, 2023 Oxford University Press 2023-10-05 /pmc/articles/PMC10555403/ http://dx.doi.org/10.1210/jendso/bvad114.1841 Text en © The Author(s) 2023. Published by Oxford University Press on behalf of the Endocrine Society. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs licence (https://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reproduction and distribution of the work, in any medium, provided the original work is not altered or transformed in any way, and that the work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Thyroid Li, Jia-Zhen Lee, Lin-Hsuan Wang, Fan-Fen Yang, Chen-Chang Jui Huang, Chun FRI495 Analytical Validation Of An Inductively Coupled Plasma Mass Spectrometry Method For Measuring Iodine Content In Breast Milk |
title | FRI495 Analytical Validation Of An Inductively Coupled Plasma Mass Spectrometry Method For Measuring Iodine Content In Breast Milk |
title_full | FRI495 Analytical Validation Of An Inductively Coupled Plasma Mass Spectrometry Method For Measuring Iodine Content In Breast Milk |
title_fullStr | FRI495 Analytical Validation Of An Inductively Coupled Plasma Mass Spectrometry Method For Measuring Iodine Content In Breast Milk |
title_full_unstemmed | FRI495 Analytical Validation Of An Inductively Coupled Plasma Mass Spectrometry Method For Measuring Iodine Content In Breast Milk |
title_short | FRI495 Analytical Validation Of An Inductively Coupled Plasma Mass Spectrometry Method For Measuring Iodine Content In Breast Milk |
title_sort | fri495 analytical validation of an inductively coupled plasma mass spectrometry method for measuring iodine content in breast milk |
topic | Thyroid |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10555403/ http://dx.doi.org/10.1210/jendso/bvad114.1841 |
work_keys_str_mv | AT lijiazhen fri495analyticalvalidationofaninductivelycoupledplasmamassspectrometrymethodformeasuringiodinecontentinbreastmilk AT leelinhsuan fri495analyticalvalidationofaninductivelycoupledplasmamassspectrometrymethodformeasuringiodinecontentinbreastmilk AT wangfanfen fri495analyticalvalidationofaninductivelycoupledplasmamassspectrometrymethodformeasuringiodinecontentinbreastmilk AT yangchenchang fri495analyticalvalidationofaninductivelycoupledplasmamassspectrometrymethodformeasuringiodinecontentinbreastmilk AT juihuangchun fri495analyticalvalidationofaninductivelycoupledplasmamassspectrometrymethodformeasuringiodinecontentinbreastmilk |