Intraoperative ticagrelor removal via hemoadsorption during on-pump coronary artery bypass grafting

OBJECTIVES: Patients on ticagrelor undergoing urgent cardiac surgery are at high risk for perioperative bleeding complications. We sought to determine whether intraoperative hemoadsorption could remove ticagrelor and lower circulating drug concentrations. METHODS: The hemoadsorption device was incor...

Descripción completa

Detalles Bibliográficos
Autores principales: Hassan, Kambiz, Geidel, Stephan, Zamvar, Vipin, Tanaka, Kenichi, Knezevic-Woods, Zelka, Wendt, Daniel, Deliargyris, Efthymios N., Storey, Robert F., Schmoeckel, Michael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10556833/
https://www.ncbi.nlm.nih.gov/pubmed/37808047
http://dx.doi.org/10.1016/j.xjon.2023.04.013
_version_ 1785116954383613952
author Hassan, Kambiz
Geidel, Stephan
Zamvar, Vipin
Tanaka, Kenichi
Knezevic-Woods, Zelka
Wendt, Daniel
Deliargyris, Efthymios N.
Storey, Robert F.
Schmoeckel, Michael
author_facet Hassan, Kambiz
Geidel, Stephan
Zamvar, Vipin
Tanaka, Kenichi
Knezevic-Woods, Zelka
Wendt, Daniel
Deliargyris, Efthymios N.
Storey, Robert F.
Schmoeckel, Michael
author_sort Hassan, Kambiz
collection PubMed
description OBJECTIVES: Patients on ticagrelor undergoing urgent cardiac surgery are at high risk for perioperative bleeding complications. We sought to determine whether intraoperative hemoadsorption could remove ticagrelor and lower circulating drug concentrations. METHODS: The hemoadsorption device was incorporated in the cardiopulmonary bypass (CPB) circuit and remained active for the duration of the pump run. Blood samples were collected before and after CPB. The main objective of the current analysis was to compare mean total plasma ticagrelor levels (ng/mL) at baseline with ticagrelor levels obtained at the end of CPB. Plasma ticagrelor levels were measured at a certified outside laboratory (LabConnect). Data are presented as mean ± standard deviation. RESULTS: A total of 11 patients undergoing urgent coronary artery bypass grafting at 3 institutions were included (mean age, 67.9 ± 9.9 years; 91% male; mean European System for Cardiac Operative Risk Evaluation II of 3.0 ± 3.3%; range, 0.7%-12.4%). Mean intraoperative hemoadsorption duration was 97.1 ± 43.4 minutes with a mean flow rate through the device of 422.9 ± 40.3 mL/min. Mean ticagrelor levels pre-CPB were 103.5 ± 63.8 ng/mL compared with mean post-CPB levels of 34.0 ± 17.5 ng/mL, representing a significant 67.1% reduction (P < .001). Intraoperative integration of the device was simple and safe without any device-related adverse events reported. CONCLUSIONS: This is the first in vivo report demonstrating that intraoperative hemoadsorption can efficiently remove ticagrelor and significantly reduce circulating drug levels. Whether active ticagrelor removal can reduce serious perioperative bleeding in patients undergoing urgent cardiac surgery is currently being evaluated in the double-blinded, randomized Safe and Timely Antithrombotic Removal–Ticagrelor (STAR-T) trial.
format Online
Article
Text
id pubmed-10556833
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-105568332023-10-07 Intraoperative ticagrelor removal via hemoadsorption during on-pump coronary artery bypass grafting Hassan, Kambiz Geidel, Stephan Zamvar, Vipin Tanaka, Kenichi Knezevic-Woods, Zelka Wendt, Daniel Deliargyris, Efthymios N. Storey, Robert F. Schmoeckel, Michael JTCVS Open Adult: Coronary OBJECTIVES: Patients on ticagrelor undergoing urgent cardiac surgery are at high risk for perioperative bleeding complications. We sought to determine whether intraoperative hemoadsorption could remove ticagrelor and lower circulating drug concentrations. METHODS: The hemoadsorption device was incorporated in the cardiopulmonary bypass (CPB) circuit and remained active for the duration of the pump run. Blood samples were collected before and after CPB. The main objective of the current analysis was to compare mean total plasma ticagrelor levels (ng/mL) at baseline with ticagrelor levels obtained at the end of CPB. Plasma ticagrelor levels were measured at a certified outside laboratory (LabConnect). Data are presented as mean ± standard deviation. RESULTS: A total of 11 patients undergoing urgent coronary artery bypass grafting at 3 institutions were included (mean age, 67.9 ± 9.9 years; 91% male; mean European System for Cardiac Operative Risk Evaluation II of 3.0 ± 3.3%; range, 0.7%-12.4%). Mean intraoperative hemoadsorption duration was 97.1 ± 43.4 minutes with a mean flow rate through the device of 422.9 ± 40.3 mL/min. Mean ticagrelor levels pre-CPB were 103.5 ± 63.8 ng/mL compared with mean post-CPB levels of 34.0 ± 17.5 ng/mL, representing a significant 67.1% reduction (P < .001). Intraoperative integration of the device was simple and safe without any device-related adverse events reported. CONCLUSIONS: This is the first in vivo report demonstrating that intraoperative hemoadsorption can efficiently remove ticagrelor and significantly reduce circulating drug levels. Whether active ticagrelor removal can reduce serious perioperative bleeding in patients undergoing urgent cardiac surgery is currently being evaluated in the double-blinded, randomized Safe and Timely Antithrombotic Removal–Ticagrelor (STAR-T) trial. Elsevier 2023-05-06 /pmc/articles/PMC10556833/ /pubmed/37808047 http://dx.doi.org/10.1016/j.xjon.2023.04.013 Text en © 2023 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Adult: Coronary
Hassan, Kambiz
Geidel, Stephan
Zamvar, Vipin
Tanaka, Kenichi
Knezevic-Woods, Zelka
Wendt, Daniel
Deliargyris, Efthymios N.
Storey, Robert F.
Schmoeckel, Michael
Intraoperative ticagrelor removal via hemoadsorption during on-pump coronary artery bypass grafting
title Intraoperative ticagrelor removal via hemoadsorption during on-pump coronary artery bypass grafting
title_full Intraoperative ticagrelor removal via hemoadsorption during on-pump coronary artery bypass grafting
title_fullStr Intraoperative ticagrelor removal via hemoadsorption during on-pump coronary artery bypass grafting
title_full_unstemmed Intraoperative ticagrelor removal via hemoadsorption during on-pump coronary artery bypass grafting
title_short Intraoperative ticagrelor removal via hemoadsorption during on-pump coronary artery bypass grafting
title_sort intraoperative ticagrelor removal via hemoadsorption during on-pump coronary artery bypass grafting
topic Adult: Coronary
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10556833/
https://www.ncbi.nlm.nih.gov/pubmed/37808047
http://dx.doi.org/10.1016/j.xjon.2023.04.013
work_keys_str_mv AT hassankambiz intraoperativeticagrelorremovalviahemoadsorptionduringonpumpcoronaryarterybypassgrafting
AT geidelstephan intraoperativeticagrelorremovalviahemoadsorptionduringonpumpcoronaryarterybypassgrafting
AT zamvarvipin intraoperativeticagrelorremovalviahemoadsorptionduringonpumpcoronaryarterybypassgrafting
AT tanakakenichi intraoperativeticagrelorremovalviahemoadsorptionduringonpumpcoronaryarterybypassgrafting
AT knezevicwoodszelka intraoperativeticagrelorremovalviahemoadsorptionduringonpumpcoronaryarterybypassgrafting
AT wendtdaniel intraoperativeticagrelorremovalviahemoadsorptionduringonpumpcoronaryarterybypassgrafting
AT deliargyrisefthymiosn intraoperativeticagrelorremovalviahemoadsorptionduringonpumpcoronaryarterybypassgrafting
AT storeyrobertf intraoperativeticagrelorremovalviahemoadsorptionduringonpumpcoronaryarterybypassgrafting
AT schmoeckelmichael intraoperativeticagrelorremovalviahemoadsorptionduringonpumpcoronaryarterybypassgrafting