Feasibility of artificial intelligence-driven interfractional monitoring of organ changes by mega-voltage computed tomography in intensity-modulated radiotherapy of prostate cancer

PURPOSE: High-dose radiotherapy (RT) for localized prostate cancer requires careful consideration of target position changes and adjacent organs-at-risk (OARs), such as the rectum and bladder. Therefore, daily monitoring of target position and OAR changes is crucial in minimizing interfractional dos...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Yohan, Choi, Hyun Joon, Kim, Hyemi, Kim, Sunghyun, Kim, Mi Sun, Cha, Hyejung, Eum, Young Ju, Cho, Hyosung, Park, Jeong Eun, You, Sei Hwan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society for Radiation Oncology 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10556843/
https://www.ncbi.nlm.nih.gov/pubmed/37793628
http://dx.doi.org/10.3857/roj.2023.00444
_version_ 1785116956707258368
author Lee, Yohan
Choi, Hyun Joon
Kim, Hyemi
Kim, Sunghyun
Kim, Mi Sun
Cha, Hyejung
Eum, Young Ju
Cho, Hyosung
Park, Jeong Eun
You, Sei Hwan
author_facet Lee, Yohan
Choi, Hyun Joon
Kim, Hyemi
Kim, Sunghyun
Kim, Mi Sun
Cha, Hyejung
Eum, Young Ju
Cho, Hyosung
Park, Jeong Eun
You, Sei Hwan
author_sort Lee, Yohan
collection PubMed
description PURPOSE: High-dose radiotherapy (RT) for localized prostate cancer requires careful consideration of target position changes and adjacent organs-at-risk (OARs), such as the rectum and bladder. Therefore, daily monitoring of target position and OAR changes is crucial in minimizing interfractional dosimetric uncertainties. For efficient monitoring of the internal condition of patients, we assessed the feasibility of an auto-segmentation of OARs on the daily acquired images, such as megavoltage computed tomography (MVCT), via a commercial artificial intelligence (AI)-based solution in this study. MATERIALS AND METHODS: We collected MVCT images weekly during the entire course of RT for 100 prostate cancer patients treated with the helical TomoTherapy system. Based on the manually contoured body outline, the bladder including prostate area, and rectal balloon regions for the 100 MVCT images, we trained the commercially available fully convolutional (FC)-DenseNet model and tested its auto-contouring performance. RESULTS: Based on the optimally determined hyperparameters, the FC-DenseNet model successfully auto-contoured all regions of interest showing high dice similarity coefficient (DSC) over 0.8 and a small mean surface distance (MSD) within 1.43 mm in reference to the manually contoured data. With this well-trained AI model, we have efficiently monitored the patient's internal condition through six MVCT scans, analyzing DSC, MSD, centroid, and volume differences. CONCLUSION: We have verified the feasibility of utilizing a commercial AI-based model for auto-segmentation with low-quality daily MVCT images. In the future, we will establish a fast and accurate auto-segmentation and internal organ monitoring system for efficiently determining the time for adaptive replanning.
format Online
Article
Text
id pubmed-10556843
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher The Korean Society for Radiation Oncology
record_format MEDLINE/PubMed
spelling pubmed-105568432023-10-07 Feasibility of artificial intelligence-driven interfractional monitoring of organ changes by mega-voltage computed tomography in intensity-modulated radiotherapy of prostate cancer Lee, Yohan Choi, Hyun Joon Kim, Hyemi Kim, Sunghyun Kim, Mi Sun Cha, Hyejung Eum, Young Ju Cho, Hyosung Park, Jeong Eun You, Sei Hwan Radiat Oncol J Original Article PURPOSE: High-dose radiotherapy (RT) for localized prostate cancer requires careful consideration of target position changes and adjacent organs-at-risk (OARs), such as the rectum and bladder. Therefore, daily monitoring of target position and OAR changes is crucial in minimizing interfractional dosimetric uncertainties. For efficient monitoring of the internal condition of patients, we assessed the feasibility of an auto-segmentation of OARs on the daily acquired images, such as megavoltage computed tomography (MVCT), via a commercial artificial intelligence (AI)-based solution in this study. MATERIALS AND METHODS: We collected MVCT images weekly during the entire course of RT for 100 prostate cancer patients treated with the helical TomoTherapy system. Based on the manually contoured body outline, the bladder including prostate area, and rectal balloon regions for the 100 MVCT images, we trained the commercially available fully convolutional (FC)-DenseNet model and tested its auto-contouring performance. RESULTS: Based on the optimally determined hyperparameters, the FC-DenseNet model successfully auto-contoured all regions of interest showing high dice similarity coefficient (DSC) over 0.8 and a small mean surface distance (MSD) within 1.43 mm in reference to the manually contoured data. With this well-trained AI model, we have efficiently monitored the patient's internal condition through six MVCT scans, analyzing DSC, MSD, centroid, and volume differences. CONCLUSION: We have verified the feasibility of utilizing a commercial AI-based model for auto-segmentation with low-quality daily MVCT images. In the future, we will establish a fast and accurate auto-segmentation and internal organ monitoring system for efficiently determining the time for adaptive replanning. The Korean Society for Radiation Oncology 2023-09 2023-09-25 /pmc/articles/PMC10556843/ /pubmed/37793628 http://dx.doi.org/10.3857/roj.2023.00444 Text en Copyright © 2023 The Korean Society for Radiation Oncology https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Yohan
Choi, Hyun Joon
Kim, Hyemi
Kim, Sunghyun
Kim, Mi Sun
Cha, Hyejung
Eum, Young Ju
Cho, Hyosung
Park, Jeong Eun
You, Sei Hwan
Feasibility of artificial intelligence-driven interfractional monitoring of organ changes by mega-voltage computed tomography in intensity-modulated radiotherapy of prostate cancer
title Feasibility of artificial intelligence-driven interfractional monitoring of organ changes by mega-voltage computed tomography in intensity-modulated radiotherapy of prostate cancer
title_full Feasibility of artificial intelligence-driven interfractional monitoring of organ changes by mega-voltage computed tomography in intensity-modulated radiotherapy of prostate cancer
title_fullStr Feasibility of artificial intelligence-driven interfractional monitoring of organ changes by mega-voltage computed tomography in intensity-modulated radiotherapy of prostate cancer
title_full_unstemmed Feasibility of artificial intelligence-driven interfractional monitoring of organ changes by mega-voltage computed tomography in intensity-modulated radiotherapy of prostate cancer
title_short Feasibility of artificial intelligence-driven interfractional monitoring of organ changes by mega-voltage computed tomography in intensity-modulated radiotherapy of prostate cancer
title_sort feasibility of artificial intelligence-driven interfractional monitoring of organ changes by mega-voltage computed tomography in intensity-modulated radiotherapy of prostate cancer
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10556843/
https://www.ncbi.nlm.nih.gov/pubmed/37793628
http://dx.doi.org/10.3857/roj.2023.00444
work_keys_str_mv AT leeyohan feasibilityofartificialintelligencedriveninterfractionalmonitoringoforganchangesbymegavoltagecomputedtomographyinintensitymodulatedradiotherapyofprostatecancer
AT choihyunjoon feasibilityofartificialintelligencedriveninterfractionalmonitoringoforganchangesbymegavoltagecomputedtomographyinintensitymodulatedradiotherapyofprostatecancer
AT kimhyemi feasibilityofartificialintelligencedriveninterfractionalmonitoringoforganchangesbymegavoltagecomputedtomographyinintensitymodulatedradiotherapyofprostatecancer
AT kimsunghyun feasibilityofartificialintelligencedriveninterfractionalmonitoringoforganchangesbymegavoltagecomputedtomographyinintensitymodulatedradiotherapyofprostatecancer
AT kimmisun feasibilityofartificialintelligencedriveninterfractionalmonitoringoforganchangesbymegavoltagecomputedtomographyinintensitymodulatedradiotherapyofprostatecancer
AT chahyejung feasibilityofartificialintelligencedriveninterfractionalmonitoringoforganchangesbymegavoltagecomputedtomographyinintensitymodulatedradiotherapyofprostatecancer
AT eumyoungju feasibilityofartificialintelligencedriveninterfractionalmonitoringoforganchangesbymegavoltagecomputedtomographyinintensitymodulatedradiotherapyofprostatecancer
AT chohyosung feasibilityofartificialintelligencedriveninterfractionalmonitoringoforganchangesbymegavoltagecomputedtomographyinintensitymodulatedradiotherapyofprostatecancer
AT parkjeongeun feasibilityofartificialintelligencedriveninterfractionalmonitoringoforganchangesbymegavoltagecomputedtomographyinintensitymodulatedradiotherapyofprostatecancer
AT youseihwan feasibilityofartificialintelligencedriveninterfractionalmonitoringoforganchangesbymegavoltagecomputedtomographyinintensitymodulatedradiotherapyofprostatecancer