Cargando…

Effect of Phase Change Material Cooling Vests on Body Thermoregulation and Thermal Comfort of Patients With Paraplegia: A Human Subject Experimental Study

STUDY DESIGN: Randomized experimental study. OBJECTIVE: Compared to able-bodied people, patients with paraplegia due to thoracic spinal cord injury (SCI) are at an increased risk of heat illnesses during exercise due to impaired thermoregulatory responses. To overcome this limitation, we investigate...

Descripción completa

Detalles Bibliográficos
Autores principales: Moussalem, Charbel K., Mneimneh, Farah, Sarieddine, Rana, Bsat, Shadi, El Houshiemy, Mohamad N., Minassian, Georges B., Ghaddar, Nesreen, Ghali, Kamel, Omeis, Ibrahim
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10556892/
https://www.ncbi.nlm.nih.gov/pubmed/34579596
http://dx.doi.org/10.1177/21925682211049167
_version_ 1785116967404830720
author Moussalem, Charbel K.
Mneimneh, Farah
Sarieddine, Rana
Bsat, Shadi
El Houshiemy, Mohamad N.
Minassian, Georges B.
Ghaddar, Nesreen
Ghali, Kamel
Omeis, Ibrahim
author_facet Moussalem, Charbel K.
Mneimneh, Farah
Sarieddine, Rana
Bsat, Shadi
El Houshiemy, Mohamad N.
Minassian, Georges B.
Ghaddar, Nesreen
Ghali, Kamel
Omeis, Ibrahim
author_sort Moussalem, Charbel K.
collection PubMed
description STUDY DESIGN: Randomized experimental study. OBJECTIVE: Compared to able-bodied people, patients with paraplegia due to thoracic spinal cord injury (SCI) are at an increased risk of heat illnesses during exercise due to impaired thermoregulatory responses. To overcome this limitation, we investigated the performance of three phase change material (PCM) cooling vests of different melting temperatures (Eijsvogels, #49) and coverage area of the trunk. METHODS: Sixteen participants were divided into three groups according to their injury level. All were tested for V20 full vest (20°C Tm, 75% coverage). Mid-thoracic and high-thoracic groups were tested for V14 vest (14°C T(m), 75% coverage). The mid-thoracic group was tested for V20 half vest (20°C T(m), 50% coverage). The participants performed a 30-min arm-crank exercise followed by a recovery period inside a controlled hot climatic chamber. The heart rate, segmental skin (T(skin)), and core temperature (T(core)) values were recorded, and subjective questionnaires were taken. RESULTS: Compared to no vest (NV) test, all the vests showed an effective decrease in T(skin) values of the trunk. However, the decrease in T(skin) was not enough to induce a significant decrease in T(core) in all three groups. Mid-thoracic and low-thoracic groups showed a reduction in the increasing T(core) by the end of the exercise and recovery period. Finally, the level of thermal comfort was enhanced for the three groups. CONCLUSION: The effectiveness of cooling vests for persons with paraplegia is dependent on injury level and thus the ratio of sensate to insensate skin. Future studies necessitate the investigation of the cooling effects of PCM vests at a lower Tm with a larger sample size.
format Online
Article
Text
id pubmed-10556892
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-105568922023-10-07 Effect of Phase Change Material Cooling Vests on Body Thermoregulation and Thermal Comfort of Patients With Paraplegia: A Human Subject Experimental Study Moussalem, Charbel K. Mneimneh, Farah Sarieddine, Rana Bsat, Shadi El Houshiemy, Mohamad N. Minassian, Georges B. Ghaddar, Nesreen Ghali, Kamel Omeis, Ibrahim Global Spine J Original Articles STUDY DESIGN: Randomized experimental study. OBJECTIVE: Compared to able-bodied people, patients with paraplegia due to thoracic spinal cord injury (SCI) are at an increased risk of heat illnesses during exercise due to impaired thermoregulatory responses. To overcome this limitation, we investigated the performance of three phase change material (PCM) cooling vests of different melting temperatures (Eijsvogels, #49) and coverage area of the trunk. METHODS: Sixteen participants were divided into three groups according to their injury level. All were tested for V20 full vest (20°C Tm, 75% coverage). Mid-thoracic and high-thoracic groups were tested for V14 vest (14°C T(m), 75% coverage). The mid-thoracic group was tested for V20 half vest (20°C T(m), 50% coverage). The participants performed a 30-min arm-crank exercise followed by a recovery period inside a controlled hot climatic chamber. The heart rate, segmental skin (T(skin)), and core temperature (T(core)) values were recorded, and subjective questionnaires were taken. RESULTS: Compared to no vest (NV) test, all the vests showed an effective decrease in T(skin) values of the trunk. However, the decrease in T(skin) was not enough to induce a significant decrease in T(core) in all three groups. Mid-thoracic and low-thoracic groups showed a reduction in the increasing T(core) by the end of the exercise and recovery period. Finally, the level of thermal comfort was enhanced for the three groups. CONCLUSION: The effectiveness of cooling vests for persons with paraplegia is dependent on injury level and thus the ratio of sensate to insensate skin. Future studies necessitate the investigation of the cooling effects of PCM vests at a lower Tm with a larger sample size. SAGE Publications 2021-09-27 2023-09 /pmc/articles/PMC10556892/ /pubmed/34579596 http://dx.doi.org/10.1177/21925682211049167 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by-nc-nd/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 License (https://creativecommons.org/licenses/by-nc-nd/4.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Articles
Moussalem, Charbel K.
Mneimneh, Farah
Sarieddine, Rana
Bsat, Shadi
El Houshiemy, Mohamad N.
Minassian, Georges B.
Ghaddar, Nesreen
Ghali, Kamel
Omeis, Ibrahim
Effect of Phase Change Material Cooling Vests on Body Thermoregulation and Thermal Comfort of Patients With Paraplegia: A Human Subject Experimental Study
title Effect of Phase Change Material Cooling Vests on Body Thermoregulation and Thermal Comfort of Patients With Paraplegia: A Human Subject Experimental Study
title_full Effect of Phase Change Material Cooling Vests on Body Thermoregulation and Thermal Comfort of Patients With Paraplegia: A Human Subject Experimental Study
title_fullStr Effect of Phase Change Material Cooling Vests on Body Thermoregulation and Thermal Comfort of Patients With Paraplegia: A Human Subject Experimental Study
title_full_unstemmed Effect of Phase Change Material Cooling Vests on Body Thermoregulation and Thermal Comfort of Patients With Paraplegia: A Human Subject Experimental Study
title_short Effect of Phase Change Material Cooling Vests on Body Thermoregulation and Thermal Comfort of Patients With Paraplegia: A Human Subject Experimental Study
title_sort effect of phase change material cooling vests on body thermoregulation and thermal comfort of patients with paraplegia: a human subject experimental study
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10556892/
https://www.ncbi.nlm.nih.gov/pubmed/34579596
http://dx.doi.org/10.1177/21925682211049167
work_keys_str_mv AT moussalemcharbelk effectofphasechangematerialcoolingvestsonbodythermoregulationandthermalcomfortofpatientswithparaplegiaahumansubjectexperimentalstudy
AT mneimnehfarah effectofphasechangematerialcoolingvestsonbodythermoregulationandthermalcomfortofpatientswithparaplegiaahumansubjectexperimentalstudy
AT sarieddinerana effectofphasechangematerialcoolingvestsonbodythermoregulationandthermalcomfortofpatientswithparaplegiaahumansubjectexperimentalstudy
AT bsatshadi effectofphasechangematerialcoolingvestsonbodythermoregulationandthermalcomfortofpatientswithparaplegiaahumansubjectexperimentalstudy
AT elhoushiemymohamadn effectofphasechangematerialcoolingvestsonbodythermoregulationandthermalcomfortofpatientswithparaplegiaahumansubjectexperimentalstudy
AT minassiangeorgesb effectofphasechangematerialcoolingvestsonbodythermoregulationandthermalcomfortofpatientswithparaplegiaahumansubjectexperimentalstudy
AT ghaddarnesreen effectofphasechangematerialcoolingvestsonbodythermoregulationandthermalcomfortofpatientswithparaplegiaahumansubjectexperimentalstudy
AT ghalikamel effectofphasechangematerialcoolingvestsonbodythermoregulationandthermalcomfortofpatientswithparaplegiaahumansubjectexperimentalstudy
AT omeisibrahim effectofphasechangematerialcoolingvestsonbodythermoregulationandthermalcomfortofpatientswithparaplegiaahumansubjectexperimentalstudy