Cargando…

Operative treatment of periprosthetic fractures of the proximal femur with a contralateral, upside-down LISS plate in elderly patients

BACKGROUND: Increasing expectancy of life and levels of activity in the growing geriatric population lead to a rising number of prosthetic implants of the hip and consequently the incidence of periprosthetic fractures of the femur increase. The fracture pattern and the possible instability of the st...

Descripción completa

Detalles Bibliográficos
Autores principales: Schmid, Marc, Gurschler-Pavotbawan, Caroline, Fries, Patrick, Kabelitz, Method, Dietrich, Michael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10557259/
https://www.ncbi.nlm.nih.gov/pubmed/37803272
http://dx.doi.org/10.1186/s12877-023-04277-3
Descripción
Sumario:BACKGROUND: Increasing expectancy of life and levels of activity in the growing geriatric population lead to a rising number of prosthetic implants of the hip and consequently the incidence of periprosthetic fractures of the femur increase. The fracture pattern and the possible instability of the stem are a challenge to the orthopaedic surgeon. Treatment options are complete replacement of the implant or a solitary osteosynthesis. The goal of this study was to analyse the feasibility of the operative intervention using a contralateral reversed anatomic distal femoral LISS® locking plate and the radiological and functional outcome in a geriatric cohort. METHODS: We included all patients older than 75 years of age with a Vancouver type B fracture, which have been treated by osteosynthesis using a LISS® (contralateral reversed) plate in our institution in an interdisciplinary ortho-geriatric setting between 7/2013 and 12/2021. Perioperative morbidities, clinical and radiological outcome during follow-up were retrospectively analysed. RESULTS: During the observed time period, 83 patients (mean age: 88 years (range: 76–103), male/female: 26/57) were treated. Most fractures were Vancouver type B2 (n = 45, 54%) followed by B1 (n = 20, 24%) and B3 (n = 18, 22%). The most prevalent postoperative surgical complication was anaemia (n = 73, 88%) followed by infections (n = 12, 14%, urinary infections, pneumonia) and cardiovascular decompensation (n = 8, 10%). Clinical and radiological follow up 6–8 weeks postoperative was possible for 59 patients (70%). The majority of them did not describe pain (n = 50, 85%) and had a good or excellent radiological outcome. Three cases needed revision surgery due to infection and another three due to non-union, loosening of the stem or an additional fracture. 1-year mortality was 30%. CONCLUSION: We are convinced that the reversed contralateral LISS-plate is an easy-to-use implant with a small complication rate but a very successful and high healing rate in a geriatric, polymorbid cohort.