Cargando…

Retrospective comparison of G-EYE balloon-colonoscopy with standard colonoscopy for increased adenoma detection rate and reduced polyp removal time

Background and study aims  The newly introduced G-EYE colonoscope (G-EYE) employs a balloon, installed at the bending section of a standard colonoscope (SC), for increasing adenoma detection and stabilizing the colonoscope tip during intervention. This retrospective work explores the effect of intro...

Descripción completa

Detalles Bibliográficos
Autores principales: Kiesslich, Ralf, Teubner, Daniel, Hoffman, Arthur, Rey, Johannes W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Georg Thieme Verlag KG 2023
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10558257/
https://www.ncbi.nlm.nih.gov/pubmed/37810901
http://dx.doi.org/10.1055/a-2005-6934
_version_ 1785117234290491392
author Kiesslich, Ralf
Teubner, Daniel
Hoffman, Arthur
Rey, Johannes W.
author_facet Kiesslich, Ralf
Teubner, Daniel
Hoffman, Arthur
Rey, Johannes W.
author_sort Kiesslich, Ralf
collection PubMed
description Background and study aims  The newly introduced G-EYE colonoscope (G-EYE) employs a balloon, installed at the bending section of a standard colonoscope (SC), for increasing adenoma detection and stabilizing the colonoscope tip during intervention. This retrospective work explores the effect of introducing G-EYE into an SC endoscopy room, in terms of adenoma detection and polyp removal time. Patients and methods  This was a single-center, retrospective study. Historical data from patients who underwent colonoscopy prior to, and following, introduction of G-EYE into a particular endoscopy room were collected and analyzed to determine adenoma detection rate (ADR), adenoma per patient (APP), and polyp removal time (PRT), in each of the SC and G-EYE groups. Results  Records of 1362 patients who underwent SC and 1433 subsequent patients who underwent G-EYE colonoscopy in the same endoscopy unit by the same endoscopists were analyzed. Following G-EYE introduction, overall ADR increased by 37.5 % ( P  < 0.0001) from 39.2 % to 53.9 %, the serrated adenoma rate increased by 47.3 % from 27.9 % to 41.1 % ( P  < 0.0001), and the APP increased by 50.6 % from 0.79 to 1.19 ( P  < 0.0001). The number of advanced adenomas increased by 32.7 %, from 19.6 % to 26.0 % of all adenomas ( P  < 0.0001). With G-EYE, average PRT was reduced overall by 29.5 % ( P  < 0.0001), and particularly for endoscopic mucosal resection (EMR) by 37.5 % for polyps measuring ≥ 5 mm to ≤ 20 mm ( P  < 0.0001) and by 29.4 % for large polyps > 20 mm ( P  < 0.0001). Conclusions  Introduction of G-EYE to an SC endoscopy room yielded considerable increase in ADR and notable reduction in PRT, particularly with the EMR technique. G-EYE balloon colonoscopy might increase the effectiveness of colorectal cancer screening and surveillance colonoscopy, and can shorten the time of endoscopic intervention.
format Online
Article
Text
id pubmed-10558257
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Georg Thieme Verlag KG
record_format MEDLINE/PubMed
spelling pubmed-105582572023-10-07 Retrospective comparison of G-EYE balloon-colonoscopy with standard colonoscopy for increased adenoma detection rate and reduced polyp removal time Kiesslich, Ralf Teubner, Daniel Hoffman, Arthur Rey, Johannes W. Endosc Int Open Background and study aims  The newly introduced G-EYE colonoscope (G-EYE) employs a balloon, installed at the bending section of a standard colonoscope (SC), for increasing adenoma detection and stabilizing the colonoscope tip during intervention. This retrospective work explores the effect of introducing G-EYE into an SC endoscopy room, in terms of adenoma detection and polyp removal time. Patients and methods  This was a single-center, retrospective study. Historical data from patients who underwent colonoscopy prior to, and following, introduction of G-EYE into a particular endoscopy room were collected and analyzed to determine adenoma detection rate (ADR), adenoma per patient (APP), and polyp removal time (PRT), in each of the SC and G-EYE groups. Results  Records of 1362 patients who underwent SC and 1433 subsequent patients who underwent G-EYE colonoscopy in the same endoscopy unit by the same endoscopists were analyzed. Following G-EYE introduction, overall ADR increased by 37.5 % ( P  < 0.0001) from 39.2 % to 53.9 %, the serrated adenoma rate increased by 47.3 % from 27.9 % to 41.1 % ( P  < 0.0001), and the APP increased by 50.6 % from 0.79 to 1.19 ( P  < 0.0001). The number of advanced adenomas increased by 32.7 %, from 19.6 % to 26.0 % of all adenomas ( P  < 0.0001). With G-EYE, average PRT was reduced overall by 29.5 % ( P  < 0.0001), and particularly for endoscopic mucosal resection (EMR) by 37.5 % for polyps measuring ≥ 5 mm to ≤ 20 mm ( P  < 0.0001) and by 29.4 % for large polyps > 20 mm ( P  < 0.0001). Conclusions  Introduction of G-EYE to an SC endoscopy room yielded considerable increase in ADR and notable reduction in PRT, particularly with the EMR technique. G-EYE balloon colonoscopy might increase the effectiveness of colorectal cancer screening and surveillance colonoscopy, and can shorten the time of endoscopic intervention. Georg Thieme Verlag KG 2023-10-06 /pmc/articles/PMC10558257/ /pubmed/37810901 http://dx.doi.org/10.1055/a-2005-6934 Text en The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited.
spellingShingle Kiesslich, Ralf
Teubner, Daniel
Hoffman, Arthur
Rey, Johannes W.
Retrospective comparison of G-EYE balloon-colonoscopy with standard colonoscopy for increased adenoma detection rate and reduced polyp removal time
title Retrospective comparison of G-EYE balloon-colonoscopy with standard colonoscopy for increased adenoma detection rate and reduced polyp removal time
title_full Retrospective comparison of G-EYE balloon-colonoscopy with standard colonoscopy for increased adenoma detection rate and reduced polyp removal time
title_fullStr Retrospective comparison of G-EYE balloon-colonoscopy with standard colonoscopy for increased adenoma detection rate and reduced polyp removal time
title_full_unstemmed Retrospective comparison of G-EYE balloon-colonoscopy with standard colonoscopy for increased adenoma detection rate and reduced polyp removal time
title_short Retrospective comparison of G-EYE balloon-colonoscopy with standard colonoscopy for increased adenoma detection rate and reduced polyp removal time
title_sort retrospective comparison of g-eye balloon-colonoscopy with standard colonoscopy for increased adenoma detection rate and reduced polyp removal time
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10558257/
https://www.ncbi.nlm.nih.gov/pubmed/37810901
http://dx.doi.org/10.1055/a-2005-6934
work_keys_str_mv AT kiesslichralf retrospectivecomparisonofgeyeballooncolonoscopywithstandardcolonoscopyforincreasedadenomadetectionrateandreducedpolypremovaltime
AT teubnerdaniel retrospectivecomparisonofgeyeballooncolonoscopywithstandardcolonoscopyforincreasedadenomadetectionrateandreducedpolypremovaltime
AT hoffmanarthur retrospectivecomparisonofgeyeballooncolonoscopywithstandardcolonoscopyforincreasedadenomadetectionrateandreducedpolypremovaltime
AT reyjohannesw retrospectivecomparisonofgeyeballooncolonoscopywithstandardcolonoscopyforincreasedadenomadetectionrateandreducedpolypremovaltime