Multi-year techno-economic assessment of proposed zero-emission hybrid community microgrid in Nigeria using HOMER

This paper presents a novel use of the HOMER Software for the multi-year economic, environmental, and energetic assessment of a proposed multi-source standalone renewable microgrid. A rural-but-rapidly-commercializing community in Nigeria's middle belt was used as a case study, with an average...

Descripción completa

Detalles Bibliográficos
Autores principales: Odetoye, O.A., Olulope, P.K., Olanrewaju, O.M., Alimi, A.O., Igbinosa, O.G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10558318/
https://www.ncbi.nlm.nih.gov/pubmed/37809769
http://dx.doi.org/10.1016/j.heliyon.2023.e19189
_version_ 1785117248769228800
author Odetoye, O.A.
Olulope, P.K.
Olanrewaju, O.M.
Alimi, A.O.
Igbinosa, O.G.
author_facet Odetoye, O.A.
Olulope, P.K.
Olanrewaju, O.M.
Alimi, A.O.
Igbinosa, O.G.
author_sort Odetoye, O.A.
collection PubMed
description This paper presents a novel use of the HOMER Software for the multi-year economic, environmental, and energetic assessment of a proposed multi-source standalone renewable microgrid. A rural-but-rapidly-commercializing community in Nigeria's middle belt was used as a case study, with an average power demand of 975 kW and average consumption of 23.028 MWh/day. A generation mix of flat-plate photovoltaic (PV) array (3 MW nominal), concentrated solar thermal (CSP, 9 MW nominal), and small hydropower (SH, up to 200 kW), with battery storage (200 strings), system converter (2.5 MW nominal) using the Oshin River was recommended as the optimal system for minimizing the cost of electricity (LCOE) in HOMER. A diesel-based system was also simulated and a multiyear analysis for a 25-year period shows that the Net Present Cost (NPC) of $55.7 million for the renewable microgrid is vastly superior to the $408 million for the diesel microgrid, with LCOE of $0.26 and $1.01 per kWh respectively. The system also saved up to 7540 metric tons of CO2 per year in emissions. The results of the study indicate the proposed microgrid as an economically and environmentally superior alternative to diesel generators in the long term, and as deserving consideration for similar applications.
format Online
Article
Text
id pubmed-10558318
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-105583182023-10-08 Multi-year techno-economic assessment of proposed zero-emission hybrid community microgrid in Nigeria using HOMER Odetoye, O.A. Olulope, P.K. Olanrewaju, O.M. Alimi, A.O. Igbinosa, O.G. Heliyon Research Article This paper presents a novel use of the HOMER Software for the multi-year economic, environmental, and energetic assessment of a proposed multi-source standalone renewable microgrid. A rural-but-rapidly-commercializing community in Nigeria's middle belt was used as a case study, with an average power demand of 975 kW and average consumption of 23.028 MWh/day. A generation mix of flat-plate photovoltaic (PV) array (3 MW nominal), concentrated solar thermal (CSP, 9 MW nominal), and small hydropower (SH, up to 200 kW), with battery storage (200 strings), system converter (2.5 MW nominal) using the Oshin River was recommended as the optimal system for minimizing the cost of electricity (LCOE) in HOMER. A diesel-based system was also simulated and a multiyear analysis for a 25-year period shows that the Net Present Cost (NPC) of $55.7 million for the renewable microgrid is vastly superior to the $408 million for the diesel microgrid, with LCOE of $0.26 and $1.01 per kWh respectively. The system also saved up to 7540 metric tons of CO2 per year in emissions. The results of the study indicate the proposed microgrid as an economically and environmentally superior alternative to diesel generators in the long term, and as deserving consideration for similar applications. Elsevier 2023-08-18 /pmc/articles/PMC10558318/ /pubmed/37809769 http://dx.doi.org/10.1016/j.heliyon.2023.e19189 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Article
Odetoye, O.A.
Olulope, P.K.
Olanrewaju, O.M.
Alimi, A.O.
Igbinosa, O.G.
Multi-year techno-economic assessment of proposed zero-emission hybrid community microgrid in Nigeria using HOMER
title Multi-year techno-economic assessment of proposed zero-emission hybrid community microgrid in Nigeria using HOMER
title_full Multi-year techno-economic assessment of proposed zero-emission hybrid community microgrid in Nigeria using HOMER
title_fullStr Multi-year techno-economic assessment of proposed zero-emission hybrid community microgrid in Nigeria using HOMER
title_full_unstemmed Multi-year techno-economic assessment of proposed zero-emission hybrid community microgrid in Nigeria using HOMER
title_short Multi-year techno-economic assessment of proposed zero-emission hybrid community microgrid in Nigeria using HOMER
title_sort multi-year techno-economic assessment of proposed zero-emission hybrid community microgrid in nigeria using homer
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10558318/
https://www.ncbi.nlm.nih.gov/pubmed/37809769
http://dx.doi.org/10.1016/j.heliyon.2023.e19189
work_keys_str_mv AT odetoyeoa multiyeartechnoeconomicassessmentofproposedzeroemissionhybridcommunitymicrogridinnigeriausinghomer
AT olulopepk multiyeartechnoeconomicassessmentofproposedzeroemissionhybridcommunitymicrogridinnigeriausinghomer
AT olanrewajuom multiyeartechnoeconomicassessmentofproposedzeroemissionhybridcommunitymicrogridinnigeriausinghomer
AT alimiao multiyeartechnoeconomicassessmentofproposedzeroemissionhybridcommunitymicrogridinnigeriausinghomer
AT igbinosaog multiyeartechnoeconomicassessmentofproposedzeroemissionhybridcommunitymicrogridinnigeriausinghomer