Cargando…

Diagnostic accuracy for CZT gamma camera compared to conventional gamma camera technique with myocardial perfusion single-photon emission computed tomography: Assessment of myocardial infarction and function

BACKGROUND: The solid-state cadmium-zinc-telluride (CZT) gamma camera for myocardial perfusion single-photon emission computed tomography (MPS) has theoretical advantages compared to the conventional gamma camera technique. This includes more sensitive detectors and better energy resolution. We aime...

Descripción completa

Detalles Bibliográficos
Autores principales: Hedeer, Fredrik, Akil, Shahnaz, Oddstig, Jenny, Hindorf, Cecilia, Arheden, Håkan, Carlsson, Marcus, Engblom, Henrik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10558368/
https://www.ncbi.nlm.nih.gov/pubmed/36913172
http://dx.doi.org/10.1007/s12350-022-03185-0
_version_ 1785117260263718912
author Hedeer, Fredrik
Akil, Shahnaz
Oddstig, Jenny
Hindorf, Cecilia
Arheden, Håkan
Carlsson, Marcus
Engblom, Henrik
author_facet Hedeer, Fredrik
Akil, Shahnaz
Oddstig, Jenny
Hindorf, Cecilia
Arheden, Håkan
Carlsson, Marcus
Engblom, Henrik
author_sort Hedeer, Fredrik
collection PubMed
description BACKGROUND: The solid-state cadmium-zinc-telluride (CZT) gamma camera for myocardial perfusion single-photon emission computed tomography (MPS) has theoretical advantages compared to the conventional gamma camera technique. This includes more sensitive detectors and better energy resolution. We aimed to explore the diagnostic performance of gated MPS with a CZT gamma camera compared to a conventional gamma camera for detection of myocardial infarct (MI) and assessment of left ventricular (LV) volumes and ejection fraction (LVEF), using cardiac magnetic resonance (CMR) as the reference method. METHODS: Seventy-three patients (26% female) with known or suspected chronic coronary syndrome were examined with gated MPS using both a CZT gamma camera and a conventional gamma camera as well as with CMR. Presence and extent of MI on MPS and late gadolinium enhancement (LGE) CMR was evaluated. For LV volumes, LVEF and LV mass, gated MPS images and cine CMR images were evaluated. RESULTS: MI was found in 42 patients on CMR. The overall sensitivity, specificity, positive and negative predictive values for the CZT and the conventional gamma camera were the same (67%, 100%, 100% and 69%). For infarct size > 3% on CMR, the sensitivity was 82% for the CZT and 73% for the conventional gamma camera, respectively. LV volumes were significantly underestimated by MPS compared to CMR (P ≤ .002 for all measures). The underestimation was slightly less pronounced for the CZT compared to the conventional gamma camera (2-10 mL, P ≤ .03 for all measures). For LVEF, however, accuracy was high for both gamma cameras. CONCLUSION: Differences between a CZT and a conventional gamma camera for detection of MI and assessment of LV volumes and LVEF are small and do not appear to be clinically significant. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s12350-022-03185-0.
format Online
Article
Text
id pubmed-10558368
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-105583682023-10-08 Diagnostic accuracy for CZT gamma camera compared to conventional gamma camera technique with myocardial perfusion single-photon emission computed tomography: Assessment of myocardial infarction and function Hedeer, Fredrik Akil, Shahnaz Oddstig, Jenny Hindorf, Cecilia Arheden, Håkan Carlsson, Marcus Engblom, Henrik J Nucl Cardiol Original Article BACKGROUND: The solid-state cadmium-zinc-telluride (CZT) gamma camera for myocardial perfusion single-photon emission computed tomography (MPS) has theoretical advantages compared to the conventional gamma camera technique. This includes more sensitive detectors and better energy resolution. We aimed to explore the diagnostic performance of gated MPS with a CZT gamma camera compared to a conventional gamma camera for detection of myocardial infarct (MI) and assessment of left ventricular (LV) volumes and ejection fraction (LVEF), using cardiac magnetic resonance (CMR) as the reference method. METHODS: Seventy-three patients (26% female) with known or suspected chronic coronary syndrome were examined with gated MPS using both a CZT gamma camera and a conventional gamma camera as well as with CMR. Presence and extent of MI on MPS and late gadolinium enhancement (LGE) CMR was evaluated. For LV volumes, LVEF and LV mass, gated MPS images and cine CMR images were evaluated. RESULTS: MI was found in 42 patients on CMR. The overall sensitivity, specificity, positive and negative predictive values for the CZT and the conventional gamma camera were the same (67%, 100%, 100% and 69%). For infarct size > 3% on CMR, the sensitivity was 82% for the CZT and 73% for the conventional gamma camera, respectively. LV volumes were significantly underestimated by MPS compared to CMR (P ≤ .002 for all measures). The underestimation was slightly less pronounced for the CZT compared to the conventional gamma camera (2-10 mL, P ≤ .03 for all measures). For LVEF, however, accuracy was high for both gamma cameras. CONCLUSION: Differences between a CZT and a conventional gamma camera for detection of MI and assessment of LV volumes and LVEF are small and do not appear to be clinically significant. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s12350-022-03185-0. Springer International Publishing 2023-03-13 2023 /pmc/articles/PMC10558368/ /pubmed/36913172 http://dx.doi.org/10.1007/s12350-022-03185-0 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Hedeer, Fredrik
Akil, Shahnaz
Oddstig, Jenny
Hindorf, Cecilia
Arheden, Håkan
Carlsson, Marcus
Engblom, Henrik
Diagnostic accuracy for CZT gamma camera compared to conventional gamma camera technique with myocardial perfusion single-photon emission computed tomography: Assessment of myocardial infarction and function
title Diagnostic accuracy for CZT gamma camera compared to conventional gamma camera technique with myocardial perfusion single-photon emission computed tomography: Assessment of myocardial infarction and function
title_full Diagnostic accuracy for CZT gamma camera compared to conventional gamma camera technique with myocardial perfusion single-photon emission computed tomography: Assessment of myocardial infarction and function
title_fullStr Diagnostic accuracy for CZT gamma camera compared to conventional gamma camera technique with myocardial perfusion single-photon emission computed tomography: Assessment of myocardial infarction and function
title_full_unstemmed Diagnostic accuracy for CZT gamma camera compared to conventional gamma camera technique with myocardial perfusion single-photon emission computed tomography: Assessment of myocardial infarction and function
title_short Diagnostic accuracy for CZT gamma camera compared to conventional gamma camera technique with myocardial perfusion single-photon emission computed tomography: Assessment of myocardial infarction and function
title_sort diagnostic accuracy for czt gamma camera compared to conventional gamma camera technique with myocardial perfusion single-photon emission computed tomography: assessment of myocardial infarction and function
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10558368/
https://www.ncbi.nlm.nih.gov/pubmed/36913172
http://dx.doi.org/10.1007/s12350-022-03185-0
work_keys_str_mv AT hedeerfredrik diagnosticaccuracyforcztgammacameracomparedtoconventionalgammacameratechniquewithmyocardialperfusionsinglephotonemissioncomputedtomographyassessmentofmyocardialinfarctionandfunction
AT akilshahnaz diagnosticaccuracyforcztgammacameracomparedtoconventionalgammacameratechniquewithmyocardialperfusionsinglephotonemissioncomputedtomographyassessmentofmyocardialinfarctionandfunction
AT oddstigjenny diagnosticaccuracyforcztgammacameracomparedtoconventionalgammacameratechniquewithmyocardialperfusionsinglephotonemissioncomputedtomographyassessmentofmyocardialinfarctionandfunction
AT hindorfcecilia diagnosticaccuracyforcztgammacameracomparedtoconventionalgammacameratechniquewithmyocardialperfusionsinglephotonemissioncomputedtomographyassessmentofmyocardialinfarctionandfunction
AT arhedenhakan diagnosticaccuracyforcztgammacameracomparedtoconventionalgammacameratechniquewithmyocardialperfusionsinglephotonemissioncomputedtomographyassessmentofmyocardialinfarctionandfunction
AT carlssonmarcus diagnosticaccuracyforcztgammacameracomparedtoconventionalgammacameratechniquewithmyocardialperfusionsinglephotonemissioncomputedtomographyassessmentofmyocardialinfarctionandfunction
AT engblomhenrik diagnosticaccuracyforcztgammacameracomparedtoconventionalgammacameratechniquewithmyocardialperfusionsinglephotonemissioncomputedtomographyassessmentofmyocardialinfarctionandfunction