Cargando…

Simultaneous uroflowmetry and urinalysis with single specimen – A prospective evaluation of automatic urine strip analyzer of ORUBA INALYS: Uroflowmetry-urinalysis combined device

OBJECTIVE: To evaluate the consistency of the urinalysis results performed with the ORUBA INALYS device, (Oruba, Ankara, Turkey) which can perform urinalysis and uroflowmetry simultaneously, with the analysis results performed with the SYSMEX UC3500 automated urine chemistry analyzer (Sysmex, Kobe,...

Descripción completa

Detalles Bibliográficos
Autores principales: Topcuoğlu, Murat, Karaburun, Murat Can, Sancı, Adem, Kokurcan, Özden, Devrim, Erdinç, Gülpınar, Ömer
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10558901/
https://www.ncbi.nlm.nih.gov/pubmed/37810061
http://dx.doi.org/10.1016/j.heliyon.2023.e19649
_version_ 1785117385502490624
author Topcuoğlu, Murat
Karaburun, Murat Can
Sancı, Adem
Kokurcan, Özden
Devrim, Erdinç
Gülpınar, Ömer
author_facet Topcuoğlu, Murat
Karaburun, Murat Can
Sancı, Adem
Kokurcan, Özden
Devrim, Erdinç
Gülpınar, Ömer
author_sort Topcuoğlu, Murat
collection PubMed
description OBJECTIVE: To evaluate the consistency of the urinalysis results performed with the ORUBA INALYS device, (Oruba, Ankara, Turkey) which can perform urinalysis and uroflowmetry simultaneously, with the analysis results performed with the SYSMEX UC3500 automated urine chemistry analyzer (Sysmex, Kobe, Japan). MATERIAL AND METHODS: In this prospective study, urinalysis of 50 male patients with lower urinary tract symptoms were evaluated. The parameters of glucose, pH, urobilinogen, bilirubin and ketone, leukocyte, protein, and blood were measured with ORUBA INALYS, and the same urine specimens collected from ORUBA INALYS by a special setup were sent to the laboratory for urinalysis with Sysmex UC-3500 to assess the concordance of the results between two devices. RESULTS: Urinalysis results in ORUBA INALYS device in terms of glucose, pH, urobilinogen, bilirubin, and ketone parameters were shown to achieve 100% agreement within ±1 category with SYSMEX UC3500 whereas these values were slightly decreased to 88%, 96%, and 98% for leukocyte, protein, and blood, respectively. Among the calculable weighted kappa values for the test parameters, the highest value was found for glucose and followed by blood, pH, leukocyte, and specific gravity respectively. CONCLUSION: Significant consistency of the urinalysis results obtained from ORUBA INALYS with those obtained from device SYSMEX UC3500 shows the reliability of the urinalysis performed with ORUBA INALYS. ORUBA INALYS could minimize costs and workload, provide time save and reduce plastic waste.
format Online
Article
Text
id pubmed-10558901
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-105589012023-10-08 Simultaneous uroflowmetry and urinalysis with single specimen – A prospective evaluation of automatic urine strip analyzer of ORUBA INALYS: Uroflowmetry-urinalysis combined device Topcuoğlu, Murat Karaburun, Murat Can Sancı, Adem Kokurcan, Özden Devrim, Erdinç Gülpınar, Ömer Heliyon Research Article OBJECTIVE: To evaluate the consistency of the urinalysis results performed with the ORUBA INALYS device, (Oruba, Ankara, Turkey) which can perform urinalysis and uroflowmetry simultaneously, with the analysis results performed with the SYSMEX UC3500 automated urine chemistry analyzer (Sysmex, Kobe, Japan). MATERIAL AND METHODS: In this prospective study, urinalysis of 50 male patients with lower urinary tract symptoms were evaluated. The parameters of glucose, pH, urobilinogen, bilirubin and ketone, leukocyte, protein, and blood were measured with ORUBA INALYS, and the same urine specimens collected from ORUBA INALYS by a special setup were sent to the laboratory for urinalysis with Sysmex UC-3500 to assess the concordance of the results between two devices. RESULTS: Urinalysis results in ORUBA INALYS device in terms of glucose, pH, urobilinogen, bilirubin, and ketone parameters were shown to achieve 100% agreement within ±1 category with SYSMEX UC3500 whereas these values were slightly decreased to 88%, 96%, and 98% for leukocyte, protein, and blood, respectively. Among the calculable weighted kappa values for the test parameters, the highest value was found for glucose and followed by blood, pH, leukocyte, and specific gravity respectively. CONCLUSION: Significant consistency of the urinalysis results obtained from ORUBA INALYS with those obtained from device SYSMEX UC3500 shows the reliability of the urinalysis performed with ORUBA INALYS. ORUBA INALYS could minimize costs and workload, provide time save and reduce plastic waste. Elsevier 2023-09-06 /pmc/articles/PMC10558901/ /pubmed/37810061 http://dx.doi.org/10.1016/j.heliyon.2023.e19649 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Article
Topcuoğlu, Murat
Karaburun, Murat Can
Sancı, Adem
Kokurcan, Özden
Devrim, Erdinç
Gülpınar, Ömer
Simultaneous uroflowmetry and urinalysis with single specimen – A prospective evaluation of automatic urine strip analyzer of ORUBA INALYS: Uroflowmetry-urinalysis combined device
title Simultaneous uroflowmetry and urinalysis with single specimen – A prospective evaluation of automatic urine strip analyzer of ORUBA INALYS: Uroflowmetry-urinalysis combined device
title_full Simultaneous uroflowmetry and urinalysis with single specimen – A prospective evaluation of automatic urine strip analyzer of ORUBA INALYS: Uroflowmetry-urinalysis combined device
title_fullStr Simultaneous uroflowmetry and urinalysis with single specimen – A prospective evaluation of automatic urine strip analyzer of ORUBA INALYS: Uroflowmetry-urinalysis combined device
title_full_unstemmed Simultaneous uroflowmetry and urinalysis with single specimen – A prospective evaluation of automatic urine strip analyzer of ORUBA INALYS: Uroflowmetry-urinalysis combined device
title_short Simultaneous uroflowmetry and urinalysis with single specimen – A prospective evaluation of automatic urine strip analyzer of ORUBA INALYS: Uroflowmetry-urinalysis combined device
title_sort simultaneous uroflowmetry and urinalysis with single specimen – a prospective evaluation of automatic urine strip analyzer of oruba inalys: uroflowmetry-urinalysis combined device
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10558901/
https://www.ncbi.nlm.nih.gov/pubmed/37810061
http://dx.doi.org/10.1016/j.heliyon.2023.e19649
work_keys_str_mv AT topcuoglumurat simultaneousuroflowmetryandurinalysiswithsinglespecimenaprospectiveevaluationofautomaticurinestripanalyzeroforubainalysuroflowmetryurinalysiscombineddevice
AT karaburunmuratcan simultaneousuroflowmetryandurinalysiswithsinglespecimenaprospectiveevaluationofautomaticurinestripanalyzeroforubainalysuroflowmetryurinalysiscombineddevice
AT sancıadem simultaneousuroflowmetryandurinalysiswithsinglespecimenaprospectiveevaluationofautomaticurinestripanalyzeroforubainalysuroflowmetryurinalysiscombineddevice
AT kokurcanozden simultaneousuroflowmetryandurinalysiswithsinglespecimenaprospectiveevaluationofautomaticurinestripanalyzeroforubainalysuroflowmetryurinalysiscombineddevice
AT devrimerdinc simultaneousuroflowmetryandurinalysiswithsinglespecimenaprospectiveevaluationofautomaticurinestripanalyzeroforubainalysuroflowmetryurinalysiscombineddevice
AT gulpınaromer simultaneousuroflowmetryandurinalysiswithsinglespecimenaprospectiveevaluationofautomaticurinestripanalyzeroforubainalysuroflowmetryurinalysiscombineddevice