Cargando…

Determining minimum number of valid days for accurate estimation of sedentary behaviour and awake-time movement behaviours using the ActivPAL3 in nursing home residents

INTRODUCTION: Scarce evidence is available about the minimum number of valid days wearing the activPAL3 to obtain a precise estimate of sedentary behaviour (SB) and awake-time movement behaviours (ATMB) in nursing home (NH) residents. The study aimed to determine the minimum number of valid days req...

Descripción completa

Detalles Bibliográficos
Autores principales: Farrés-Godayol, Pau, Ruiz-Díaz, Miguel Ángel, Dall, Philippa, Skelton, Dawn A., Minobes-Molina, Eduard, Jerez-Roig, Javier, Giné-Garriga, Maria
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10559597/
https://www.ncbi.nlm.nih.gov/pubmed/37805448
http://dx.doi.org/10.1186/s11556-023-00329-0
_version_ 1785117536834027520
author Farrés-Godayol, Pau
Ruiz-Díaz, Miguel Ángel
Dall, Philippa
Skelton, Dawn A.
Minobes-Molina, Eduard
Jerez-Roig, Javier
Giné-Garriga, Maria
author_facet Farrés-Godayol, Pau
Ruiz-Díaz, Miguel Ángel
Dall, Philippa
Skelton, Dawn A.
Minobes-Molina, Eduard
Jerez-Roig, Javier
Giné-Garriga, Maria
author_sort Farrés-Godayol, Pau
collection PubMed
description INTRODUCTION: Scarce evidence is available about the minimum number of valid days wearing the activPAL3 to obtain a precise estimate of sedentary behaviour (SB) and awake-time movement behaviours (ATMB) in nursing home (NH) residents. The study aimed to determine the minimum number of valid days required for accurately estimate SB and ATMB using the activPAL3 device in NH residents. It also investigated how the starting point of a day (the 24-h period) impacted reliability. METHODS: Participants wore an activPAL3 for 7 consecutive days. The data was classified in two-time blocks (00:00 Ante Meridiem (AM)—00:00 AM midnight vs 12:00 Post Meridiam (PM) -12:00 PM midday) and the sample was stratified into two groups according to their capacity to stand and walk, to examine if timing of sampling or physical functioning affected minimum wear time. SB, ATMB, sociodemographic, and health-related variables were collected. Sensitivity of the time-blocks were tested through the dispersion frequencies and differences between blocks through Kolmogorov–Smirnov test for normality; parametric variables through two-related means T-test and Wilcoxon test for non-parametric data. Reliability was assessed with the Cronbach's Alpha and the intra-class correlation coefficient (ICC), using a one-factor model estimating the reliability for each measurement day loading in the same latent factor. RESULTS: Ninety-five NH residents (81.1% women; age = 85.8 ± 7.2 years) were included. The midnight block had higher reliability, sensitivity and no statistically significant differences between days were found. At least three consecutive days of monitoring were necessary to achieve a reliability of ICC ≥ 0.8 for those NH residents able to stand and walk and six days for those unable. CONCLUSIONS: NH residents who are able to stand and walk require a minimum of three consecutive days wearing the device, while those who are unable require at least six days due to their highly homogenous daily routines and sensitivity to PA events. Regardless of the activPAL3 recording start time, data processing should reference the midnight time block.
format Online
Article
Text
id pubmed-10559597
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-105595972023-10-08 Determining minimum number of valid days for accurate estimation of sedentary behaviour and awake-time movement behaviours using the ActivPAL3 in nursing home residents Farrés-Godayol, Pau Ruiz-Díaz, Miguel Ángel Dall, Philippa Skelton, Dawn A. Minobes-Molina, Eduard Jerez-Roig, Javier Giné-Garriga, Maria Eur Rev Aging Phys Act Research Article INTRODUCTION: Scarce evidence is available about the minimum number of valid days wearing the activPAL3 to obtain a precise estimate of sedentary behaviour (SB) and awake-time movement behaviours (ATMB) in nursing home (NH) residents. The study aimed to determine the minimum number of valid days required for accurately estimate SB and ATMB using the activPAL3 device in NH residents. It also investigated how the starting point of a day (the 24-h period) impacted reliability. METHODS: Participants wore an activPAL3 for 7 consecutive days. The data was classified in two-time blocks (00:00 Ante Meridiem (AM)—00:00 AM midnight vs 12:00 Post Meridiam (PM) -12:00 PM midday) and the sample was stratified into two groups according to their capacity to stand and walk, to examine if timing of sampling or physical functioning affected minimum wear time. SB, ATMB, sociodemographic, and health-related variables were collected. Sensitivity of the time-blocks were tested through the dispersion frequencies and differences between blocks through Kolmogorov–Smirnov test for normality; parametric variables through two-related means T-test and Wilcoxon test for non-parametric data. Reliability was assessed with the Cronbach's Alpha and the intra-class correlation coefficient (ICC), using a one-factor model estimating the reliability for each measurement day loading in the same latent factor. RESULTS: Ninety-five NH residents (81.1% women; age = 85.8 ± 7.2 years) were included. The midnight block had higher reliability, sensitivity and no statistically significant differences between days were found. At least three consecutive days of monitoring were necessary to achieve a reliability of ICC ≥ 0.8 for those NH residents able to stand and walk and six days for those unable. CONCLUSIONS: NH residents who are able to stand and walk require a minimum of three consecutive days wearing the device, while those who are unable require at least six days due to their highly homogenous daily routines and sensitivity to PA events. Regardless of the activPAL3 recording start time, data processing should reference the midnight time block. BioMed Central 2023-10-07 /pmc/articles/PMC10559597/ /pubmed/37805448 http://dx.doi.org/10.1186/s11556-023-00329-0 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Farrés-Godayol, Pau
Ruiz-Díaz, Miguel Ángel
Dall, Philippa
Skelton, Dawn A.
Minobes-Molina, Eduard
Jerez-Roig, Javier
Giné-Garriga, Maria
Determining minimum number of valid days for accurate estimation of sedentary behaviour and awake-time movement behaviours using the ActivPAL3 in nursing home residents
title Determining minimum number of valid days for accurate estimation of sedentary behaviour and awake-time movement behaviours using the ActivPAL3 in nursing home residents
title_full Determining minimum number of valid days for accurate estimation of sedentary behaviour and awake-time movement behaviours using the ActivPAL3 in nursing home residents
title_fullStr Determining minimum number of valid days for accurate estimation of sedentary behaviour and awake-time movement behaviours using the ActivPAL3 in nursing home residents
title_full_unstemmed Determining minimum number of valid days for accurate estimation of sedentary behaviour and awake-time movement behaviours using the ActivPAL3 in nursing home residents
title_short Determining minimum number of valid days for accurate estimation of sedentary behaviour and awake-time movement behaviours using the ActivPAL3 in nursing home residents
title_sort determining minimum number of valid days for accurate estimation of sedentary behaviour and awake-time movement behaviours using the activpal3 in nursing home residents
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10559597/
https://www.ncbi.nlm.nih.gov/pubmed/37805448
http://dx.doi.org/10.1186/s11556-023-00329-0
work_keys_str_mv AT farresgodayolpau determiningminimumnumberofvaliddaysforaccurateestimationofsedentarybehaviourandawaketimemovementbehavioursusingtheactivpal3innursinghomeresidents
AT ruizdiazmiguelangel determiningminimumnumberofvaliddaysforaccurateestimationofsedentarybehaviourandawaketimemovementbehavioursusingtheactivpal3innursinghomeresidents
AT dallphilippa determiningminimumnumberofvaliddaysforaccurateestimationofsedentarybehaviourandawaketimemovementbehavioursusingtheactivpal3innursinghomeresidents
AT skeltondawna determiningminimumnumberofvaliddaysforaccurateestimationofsedentarybehaviourandawaketimemovementbehavioursusingtheactivpal3innursinghomeresidents
AT minobesmolinaeduard determiningminimumnumberofvaliddaysforaccurateestimationofsedentarybehaviourandawaketimemovementbehavioursusingtheactivpal3innursinghomeresidents
AT jerezroigjavier determiningminimumnumberofvaliddaysforaccurateestimationofsedentarybehaviourandawaketimemovementbehavioursusingtheactivpal3innursinghomeresidents
AT ginegarrigamaria determiningminimumnumberofvaliddaysforaccurateestimationofsedentarybehaviourandawaketimemovementbehavioursusingtheactivpal3innursinghomeresidents