Cargando…

The characteristics of particulate matter in different subway station environmental control systems

Particulate matter (PM2.5, PM10) in urban subway stations can significantly impact passengers' health. The particle concentration in subway stations is influenced by many factors. However, few existing studies have explored the impact of environmental control systems in-depth, especially under...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Xinru, Xia, Liang, Pei, Fei, Wang, Zu, Liu, Yiqiao, Chang, Li, Pan, Song
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10559854/
https://www.ncbi.nlm.nih.gov/pubmed/37809848
http://dx.doi.org/10.1016/j.heliyon.2023.e20116
Descripción
Sumario:Particulate matter (PM2.5, PM10) in urban subway stations can significantly impact passengers' health. The particle concentration in subway stations is influenced by many factors. However, few existing studies have explored the impact of environmental control systems in-depth, especially under different outdoor pollution conditions. To address this research gap, this study focused on measuring and comparing the characteristics of PM2.5 and PM10 at subway stations with three control systems (open, closed, and screen door) under varying pollution conditions in Beijing. Particle concentrations from platforms, carriages, and outdoors were monitored and analyzed using statistical methods. The results showed that the particle concentration in the closed system was generally 20–40 μg/m(3) higher than that in the screen system at the platform, which might be attributed to the piston wind, as the air from the tunnel with a lot of dirt. The pollution in the carriage was more severe for the open system than that of the screen system. The PM2.5/PM10 ratio in the carriage was 91%, 90%, and 83.84% for the closed, open, and screen systems, respectively. This indicates that the screen door could reduce the particle concentration in the platform to 10%–50%. The particle concentration varied among subway stations with different environmental control systems, suggesting that the prevention and control strategies for particulate matter pollution should be different for stations with different systems.