Application of the single-port robotic platform during radical nephroureterectomy for upper tract urothelial carcinoma: feasibility of the single-port robot in the multi-quadrant setting
Urothelial carcinoma of the upper tract (UTUC) is a malignancy that accounts for 5–10% of all urothelial carcinomas. Radical surgery is the primary treatment option due to the high rate of invasive stages at the time of diagnosis. Nephroureterectomy (NU) with bladder cuff excision is the current sta...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AME Publishing Company
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10560342/ https://www.ncbi.nlm.nih.gov/pubmed/37814701 http://dx.doi.org/10.21037/tau-23-48 |
_version_ | 1785117712120283136 |
---|---|
author | Pellegrino, Antony A. Mima, Mahmoud Crivellaro, Simone |
author_facet | Pellegrino, Antony A. Mima, Mahmoud Crivellaro, Simone |
author_sort | Pellegrino, Antony A. |
collection | PubMed |
description | Urothelial carcinoma of the upper tract (UTUC) is a malignancy that accounts for 5–10% of all urothelial carcinomas. Radical surgery is the primary treatment option due to the high rate of invasive stages at the time of diagnosis. Nephroureterectomy (NU) with bladder cuff excision is the current standard of care. While laparoscopic NU has been established since 1991, many centres still perform open surgery due to the complexity of laparoscopic instrumentation and the steep learning curve for excising the bladder cuff. With the increasing adoption of the multi-port (MP) robotic surgery, NU has increasingly been performed using this platform. The use of MP robotic systems for NU has been challenged by the need for patient repositioning and/or redocking of the robot, which can consume valuable operative time. The transition from the daVinci Si to the daVinci Xi system has seen a noticeable reduction in redocking and patient repositioning. However, owing to the multi-quadrant nature of the surgery in question, the use of multiple ports and external instrument clashing are still persistent problems. Moreover, there is a growing interest in utilizing a retroperitoneal approach for robot-assisted NU due to its potential benefits such as improved control of hilar structures, reduction of blood loss, shorter operative time and hospital stay, reduced complications and decreased postoperative discomfort. The application of the daVinci single-port (SP) robotic platform during radical NU for UTUC is feasible and has the potential to improve the current surgical approach. Indeed, the use of a SP platform may solve the problem of patient repositioning and redocking of the robot, improve superficial aesthetic outcome and minimize external instrument clashing. While maintaining an optimal oncological control, the retroperitoneal approach, which has been difficult to replicate and adopt using the MP approach, may become standard practice. However, more studies are needed to confirm the benefit of this approach and ultimately determine the impact of the daVinci SP on the management of UTUC. |
format | Online Article Text |
id | pubmed-10560342 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | AME Publishing Company |
record_format | MEDLINE/PubMed |
spelling | pubmed-105603422023-10-09 Application of the single-port robotic platform during radical nephroureterectomy for upper tract urothelial carcinoma: feasibility of the single-port robot in the multi-quadrant setting Pellegrino, Antony A. Mima, Mahmoud Crivellaro, Simone Transl Androl Urol Review Article Urothelial carcinoma of the upper tract (UTUC) is a malignancy that accounts for 5–10% of all urothelial carcinomas. Radical surgery is the primary treatment option due to the high rate of invasive stages at the time of diagnosis. Nephroureterectomy (NU) with bladder cuff excision is the current standard of care. While laparoscopic NU has been established since 1991, many centres still perform open surgery due to the complexity of laparoscopic instrumentation and the steep learning curve for excising the bladder cuff. With the increasing adoption of the multi-port (MP) robotic surgery, NU has increasingly been performed using this platform. The use of MP robotic systems for NU has been challenged by the need for patient repositioning and/or redocking of the robot, which can consume valuable operative time. The transition from the daVinci Si to the daVinci Xi system has seen a noticeable reduction in redocking and patient repositioning. However, owing to the multi-quadrant nature of the surgery in question, the use of multiple ports and external instrument clashing are still persistent problems. Moreover, there is a growing interest in utilizing a retroperitoneal approach for robot-assisted NU due to its potential benefits such as improved control of hilar structures, reduction of blood loss, shorter operative time and hospital stay, reduced complications and decreased postoperative discomfort. The application of the daVinci single-port (SP) robotic platform during radical NU for UTUC is feasible and has the potential to improve the current surgical approach. Indeed, the use of a SP platform may solve the problem of patient repositioning and redocking of the robot, improve superficial aesthetic outcome and minimize external instrument clashing. While maintaining an optimal oncological control, the retroperitoneal approach, which has been difficult to replicate and adopt using the MP approach, may become standard practice. However, more studies are needed to confirm the benefit of this approach and ultimately determine the impact of the daVinci SP on the management of UTUC. AME Publishing Company 2023-08-16 2023-09-30 /pmc/articles/PMC10560342/ /pubmed/37814701 http://dx.doi.org/10.21037/tau-23-48 Text en 2023 Translational Andrology and Urology. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) . |
spellingShingle | Review Article Pellegrino, Antony A. Mima, Mahmoud Crivellaro, Simone Application of the single-port robotic platform during radical nephroureterectomy for upper tract urothelial carcinoma: feasibility of the single-port robot in the multi-quadrant setting |
title | Application of the single-port robotic platform during radical nephroureterectomy for upper tract urothelial carcinoma: feasibility of the single-port robot in the multi-quadrant setting |
title_full | Application of the single-port robotic platform during radical nephroureterectomy for upper tract urothelial carcinoma: feasibility of the single-port robot in the multi-quadrant setting |
title_fullStr | Application of the single-port robotic platform during radical nephroureterectomy for upper tract urothelial carcinoma: feasibility of the single-port robot in the multi-quadrant setting |
title_full_unstemmed | Application of the single-port robotic platform during radical nephroureterectomy for upper tract urothelial carcinoma: feasibility of the single-port robot in the multi-quadrant setting |
title_short | Application of the single-port robotic platform during radical nephroureterectomy for upper tract urothelial carcinoma: feasibility of the single-port robot in the multi-quadrant setting |
title_sort | application of the single-port robotic platform during radical nephroureterectomy for upper tract urothelial carcinoma: feasibility of the single-port robot in the multi-quadrant setting |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10560342/ https://www.ncbi.nlm.nih.gov/pubmed/37814701 http://dx.doi.org/10.21037/tau-23-48 |
work_keys_str_mv | AT pellegrinoantonya applicationofthesingleportroboticplatformduringradicalnephroureterectomyforuppertracturothelialcarcinomafeasibilityofthesingleportrobotinthemultiquadrantsetting AT mimamahmoud applicationofthesingleportroboticplatformduringradicalnephroureterectomyforuppertracturothelialcarcinomafeasibilityofthesingleportrobotinthemultiquadrantsetting AT crivellarosimone applicationofthesingleportroboticplatformduringradicalnephroureterectomyforuppertracturothelialcarcinomafeasibilityofthesingleportrobotinthemultiquadrantsetting |