Cargando…

Measurement of Occupational Eye and Thyroid Radiation Doses in Pediatric Interventional Cardiologists at a Tertiary Hospital

Background Advances in imaging techniques have led to increased utilization of imaging devices in catheterization laboratories. Invasive surgical procedures for cardiac disorders have been largely replaced by fluoroscopic cardiac catheterization. With this increase, concerns and risks associated wit...

Descripción completa

Detalles Bibliográficos
Autores principales: Khafaji, Mawya, Ashour, Tariq M, Mozahim, Naif F, Tashkandi, Abdullah, Alqarni, Basil, Malaikah, Abdulrahman A, Bagabas, Abdulaziz K, Alwasabi, Abdullah A, Albahiti, Sarah K
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10560443/
https://www.ncbi.nlm.nih.gov/pubmed/37814769
http://dx.doi.org/10.7759/cureus.44894
Descripción
Sumario:Background Advances in imaging techniques have led to increased utilization of imaging devices in catheterization laboratories. Invasive surgical procedures for cardiac disorders have been largely replaced by fluoroscopic cardiac catheterization. With this increase, concerns and risks associated with exposure to ionizing radiation among interventional cardiologists are growing. This study aims to measure and compare the occupational doses to the eye lens and thyroid of pediatric interventional cardiologists during different procedures in the catheterization laboratory and its significance. Methodology In this study, cardiologists wore bandanas with attached dosimeters to measure the absorbed doses to the eyes and thyroid gland. The dosimeters were collected for reading. The procedure types were also collected. In addition, the total fluoroscopy time and tube voltage of the biplane machine were measured. SPSS version 23 (IBM Corp., Armonk, NY, USA) was used to analyze the data. The characteristics of the study sample were described using simple counts and percentages, whereas means and standard deviations were used for continuous variables. Statistical significance was set at p-values <0.05. Results A total of 93 procedures were evaluated. The mean absorbed doses for all 93 procedures in both eyes and thyroid were 0.09 mGy and 0.08 mGy, respectively. A significant difference was found between the left and right eye measurements (p = 0.034), with higher doses administered to the left eye. However, no significant difference was observed between the right and left thyroid doses (p = 0.281). Significant correlations were found between the eye and thyroid doses and the procedure type (p = 0.02 and p = 0.009, respectively). Conclusions A significant amount of radiation was measured in the measurements of both organs. In addition, radiation dose measurements varied between different types of procedures. Our current results indicate the importance and necessity of applying the radiation protection concept of dose optimization.