Value of a novel Y-Z magnetic totally implantable venous access port in improving the success rate of one-time needle insertion
BACKGROUND AND OBJECTIVES: A totally implantable venous access port (TIVAP) is a commonly used intravenous infusion device for patients receiving chemotherapy or long-term infusion therapy. To improve the success rate of one-time insertion of the Huber needle, we developed a novel Y-Z magnetic TIVAP...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10560742/ https://www.ncbi.nlm.nih.gov/pubmed/37818210 http://dx.doi.org/10.3389/fsurg.2023.1241780 |
_version_ | 1785117787888287744 |
---|---|
author | Zhang, Miaomiao Lyu, Xin Wang, Juanjuan Shi, Aihua Zheng, Yunyun Lyu, Yi Yan, Xiaopeng |
author_facet | Zhang, Miaomiao Lyu, Xin Wang, Juanjuan Shi, Aihua Zheng, Yunyun Lyu, Yi Yan, Xiaopeng |
author_sort | Zhang, Miaomiao |
collection | PubMed |
description | BACKGROUND AND OBJECTIVES: A totally implantable venous access port (TIVAP) is a commonly used intravenous infusion device for patients receiving chemotherapy or long-term infusion therapy. To improve the success rate of one-time insertion of the Huber needle, we developed a novel Y-Z magnetic TIVAP (Y-Z MTIVAP), which we produced using three-dimensional printing technology. MATERIALS AND METHODS: The Y-Z MTIVAP includes a magnetic port body and a magnetic positioning device. For testing, we established four venous port implantation models using the two types of TIVAPs and two implantation depth ranges (≤5 mm and >5 mm). Twenty nurses performed Huber needle puncture with the four models, and we recorded the number of attempts required for successful needle insertion, the operation time, and the operator's satisfaction. RESULTS: The success rate for one-time needle insertion with the Y-Z MTIVAP was significantly higher than that with the traditional TIVAP at either depth range (100% vs. 75% at ≤5 mm, p = 0.047; 95% vs. 35% at >5 mm, p < 0.001). With increasing implantation depth, the success rate for one-time insertion was significantly reduced with the traditional TIVAP (75% at ≤5 mm vs. 35% vs. >5 mm, p = 0.025), but the success rate with the Y-Z MTIVAP was not significantly affected (100% vs. 95%, p = 1.000). The operation time with the Y-Z MTIVAP was significantly shorter than that with the traditional TIVAP at either depth range (both p < 0.001), and 90% of operators reported that the Y-Z MTIVAP was superior to the traditional TIVAP. CONCLUSIONS: The theoretical design of Y-Z MTIVAP is feasible, and the preliminary in vitro simulation experiment shows that it can significantly improve puncture success rate and shortened operation time. |
format | Online Article Text |
id | pubmed-10560742 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-105607422023-10-10 Value of a novel Y-Z magnetic totally implantable venous access port in improving the success rate of one-time needle insertion Zhang, Miaomiao Lyu, Xin Wang, Juanjuan Shi, Aihua Zheng, Yunyun Lyu, Yi Yan, Xiaopeng Front Surg Surgery BACKGROUND AND OBJECTIVES: A totally implantable venous access port (TIVAP) is a commonly used intravenous infusion device for patients receiving chemotherapy or long-term infusion therapy. To improve the success rate of one-time insertion of the Huber needle, we developed a novel Y-Z magnetic TIVAP (Y-Z MTIVAP), which we produced using three-dimensional printing technology. MATERIALS AND METHODS: The Y-Z MTIVAP includes a magnetic port body and a magnetic positioning device. For testing, we established four venous port implantation models using the two types of TIVAPs and two implantation depth ranges (≤5 mm and >5 mm). Twenty nurses performed Huber needle puncture with the four models, and we recorded the number of attempts required for successful needle insertion, the operation time, and the operator's satisfaction. RESULTS: The success rate for one-time needle insertion with the Y-Z MTIVAP was significantly higher than that with the traditional TIVAP at either depth range (100% vs. 75% at ≤5 mm, p = 0.047; 95% vs. 35% at >5 mm, p < 0.001). With increasing implantation depth, the success rate for one-time insertion was significantly reduced with the traditional TIVAP (75% at ≤5 mm vs. 35% vs. >5 mm, p = 0.025), but the success rate with the Y-Z MTIVAP was not significantly affected (100% vs. 95%, p = 1.000). The operation time with the Y-Z MTIVAP was significantly shorter than that with the traditional TIVAP at either depth range (both p < 0.001), and 90% of operators reported that the Y-Z MTIVAP was superior to the traditional TIVAP. CONCLUSIONS: The theoretical design of Y-Z MTIVAP is feasible, and the preliminary in vitro simulation experiment shows that it can significantly improve puncture success rate and shortened operation time. Frontiers Media S.A. 2023-09-25 /pmc/articles/PMC10560742/ /pubmed/37818210 http://dx.doi.org/10.3389/fsurg.2023.1241780 Text en © 2023 Zhang, Lyu, Wang, Shi, Zheng, Lyu and Yan. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/) . The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Surgery Zhang, Miaomiao Lyu, Xin Wang, Juanjuan Shi, Aihua Zheng, Yunyun Lyu, Yi Yan, Xiaopeng Value of a novel Y-Z magnetic totally implantable venous access port in improving the success rate of one-time needle insertion |
title | Value of a novel Y-Z magnetic totally implantable venous access port in improving the success rate of one-time needle insertion |
title_full | Value of a novel Y-Z magnetic totally implantable venous access port in improving the success rate of one-time needle insertion |
title_fullStr | Value of a novel Y-Z magnetic totally implantable venous access port in improving the success rate of one-time needle insertion |
title_full_unstemmed | Value of a novel Y-Z magnetic totally implantable venous access port in improving the success rate of one-time needle insertion |
title_short | Value of a novel Y-Z magnetic totally implantable venous access port in improving the success rate of one-time needle insertion |
title_sort | value of a novel y-z magnetic totally implantable venous access port in improving the success rate of one-time needle insertion |
topic | Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10560742/ https://www.ncbi.nlm.nih.gov/pubmed/37818210 http://dx.doi.org/10.3389/fsurg.2023.1241780 |
work_keys_str_mv | AT zhangmiaomiao valueofanovelyzmagnetictotallyimplantablevenousaccessportinimprovingthesuccessrateofonetimeneedleinsertion AT lyuxin valueofanovelyzmagnetictotallyimplantablevenousaccessportinimprovingthesuccessrateofonetimeneedleinsertion AT wangjuanjuan valueofanovelyzmagnetictotallyimplantablevenousaccessportinimprovingthesuccessrateofonetimeneedleinsertion AT shiaihua valueofanovelyzmagnetictotallyimplantablevenousaccessportinimprovingthesuccessrateofonetimeneedleinsertion AT zhengyunyun valueofanovelyzmagnetictotallyimplantablevenousaccessportinimprovingthesuccessrateofonetimeneedleinsertion AT lyuyi valueofanovelyzmagnetictotallyimplantablevenousaccessportinimprovingthesuccessrateofonetimeneedleinsertion AT yanxiaopeng valueofanovelyzmagnetictotallyimplantablevenousaccessportinimprovingthesuccessrateofonetimeneedleinsertion |