Cargando…
A case of mitomycin C toxicity after XEN gel stent implantation with the XEN air technique in a glaucoma patient
BACKGROUND: To discuss the first case of mitomycin C (MMC) toxicity after XEN® gel stent implantation in a glaucoma patient, conducted using the XEN “air” technique with an ophthalmic viscosurgical device (OVD). CASE PRESENTATION: A 44-year-old Asian male presented with increased intraocular pressur...
Autores principales: | Baeg, Joon Young, Choi, Han Sol, Lee, Si Hyung |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10563329/ https://www.ncbi.nlm.nih.gov/pubmed/37817107 http://dx.doi.org/10.1186/s12886-023-03152-4 |
Ejemplares similares
-
XEN(®)-63 Compared to XEN(®)-45 Gel Stents to Reduce Intraocular Pressure in Glaucoma
por: Evers, Charlotte, et al.
Publicado: (2023) -
Bilateral XEN Gel Stent Implantation in Juvenile-Onset Open-Angle Glaucoma
por: Klug, Emma, et al.
Publicado: (2020) -
XEN Gel Stent in the management of primary open-angle glaucoma
por: Post, Michał, et al.
Publicado: (2020) -
Choroidal Detachment after XEN Gel Stent Implantation
por: Cutolo, Carlo Alberto, et al.
Publicado: (2021) -
“Air and Visco” Technique: A Promising Innovation in the Surgical Implantation of the Xen Gel Stent Device
por: Franco, Fabrizio, et al.
Publicado: (2023)