Cargando…
A New Digital Point-of-Care Tool With Advanced Blood Glucose Measuring Technology
cobas(®) pulse is a point-of-care blood glucose (BG) measuring system for multiple-patient use in professional healthcare settings. The system provides advances in connectivity and BG measuring technology, and has multiple fail-safes to improve accuracy and reduce the risk of user error. Flavin aden...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10563539/ https://www.ncbi.nlm.nih.gov/pubmed/35510612 http://dx.doi.org/10.1177/19322968221092763 |
_version_ | 1785118355950141440 |
---|---|
author | Gessler, Simon Porsch, Ulrich Klonoff, David C. Marquant, Michael |
author_facet | Gessler, Simon Porsch, Ulrich Klonoff, David C. Marquant, Michael |
author_sort | Gessler, Simon |
collection | PubMed |
description | cobas(®) pulse is a point-of-care blood glucose (BG) measuring system for multiple-patient use in professional healthcare settings. The system provides advances in connectivity and BG measuring technology, and has multiple fail-safes to improve accuracy and reduce the risk of user error. Flavin adenine dinucleotide-dependent glucose dehydrogenase on the working electrode catalyzes oxidation of β-D-glucose in the blood sample. A redox mediator/electron acceptor, on both the working and the counter electrode, facilitates diffusion of electrons in proportion to the glucose concentration and compensates for the effects of potential interfering agents. During development, >1 million test strip measurements were performed using >8000 test scenarios to refine the algorithm model. No clinically relevant interference was identified with extreme variations in blood properties and drugs in whole blood samples. |
format | Online Article Text |
id | pubmed-10563539 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-105635392023-10-11 A New Digital Point-of-Care Tool With Advanced Blood Glucose Measuring Technology Gessler, Simon Porsch, Ulrich Klonoff, David C. Marquant, Michael J Diabetes Sci Technol Technology Reports cobas(®) pulse is a point-of-care blood glucose (BG) measuring system for multiple-patient use in professional healthcare settings. The system provides advances in connectivity and BG measuring technology, and has multiple fail-safes to improve accuracy and reduce the risk of user error. Flavin adenine dinucleotide-dependent glucose dehydrogenase on the working electrode catalyzes oxidation of β-D-glucose in the blood sample. A redox mediator/electron acceptor, on both the working and the counter electrode, facilitates diffusion of electrons in proportion to the glucose concentration and compensates for the effects of potential interfering agents. During development, >1 million test strip measurements were performed using >8000 test scenarios to refine the algorithm model. No clinically relevant interference was identified with extreme variations in blood properties and drugs in whole blood samples. SAGE Publications 2022-05-05 /pmc/articles/PMC10563539/ /pubmed/35510612 http://dx.doi.org/10.1177/19322968221092763 Text en © 2022 Diabetes Technology Society https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Technology Reports Gessler, Simon Porsch, Ulrich Klonoff, David C. Marquant, Michael A New Digital Point-of-Care Tool With Advanced Blood Glucose Measuring Technology |
title | A New Digital Point-of-Care Tool With Advanced Blood Glucose Measuring Technology |
title_full | A New Digital Point-of-Care Tool With Advanced Blood Glucose Measuring Technology |
title_fullStr | A New Digital Point-of-Care Tool With Advanced Blood Glucose Measuring Technology |
title_full_unstemmed | A New Digital Point-of-Care Tool With Advanced Blood Glucose Measuring Technology |
title_short | A New Digital Point-of-Care Tool With Advanced Blood Glucose Measuring Technology |
title_sort | new digital point-of-care tool with advanced blood glucose measuring technology |
topic | Technology Reports |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10563539/ https://www.ncbi.nlm.nih.gov/pubmed/35510612 http://dx.doi.org/10.1177/19322968221092763 |
work_keys_str_mv | AT gesslersimon anewdigitalpointofcaretoolwithadvancedbloodglucosemeasuringtechnology AT porschulrich anewdigitalpointofcaretoolwithadvancedbloodglucosemeasuringtechnology AT klonoffdavidc anewdigitalpointofcaretoolwithadvancedbloodglucosemeasuringtechnology AT marquantmichael anewdigitalpointofcaretoolwithadvancedbloodglucosemeasuringtechnology AT gesslersimon newdigitalpointofcaretoolwithadvancedbloodglucosemeasuringtechnology AT porschulrich newdigitalpointofcaretoolwithadvancedbloodglucosemeasuringtechnology AT klonoffdavidc newdigitalpointofcaretoolwithadvancedbloodglucosemeasuringtechnology AT marquantmichael newdigitalpointofcaretoolwithadvancedbloodglucosemeasuringtechnology |