Cargando…

Evaluation of neo-implant abutment junction sealing gel among Indian patients

With the advent of various implant abutment junctions, the ultimate aim is to develop a precise implant abutment junction with negligible micro-leakage. However precise the mechanical connection is, there seems to be a negligible amount of micro-leakage that is present that can be addressed with the...

Descripción completa

Detalles Bibliográficos
Autores principales: Mehta, Saumya, Selvaganesh, Sahana, Nesappan, Thiyaneswaran, Veeraraghavan, Vishnu Priya, Sathishkumar, Palanivel, Eswaramoorthy, Rajalakshmanan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Biomedical Informatics 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10563552/
https://www.ncbi.nlm.nih.gov/pubmed/37822813
http://dx.doi.org/10.6026/97320630019502
_version_ 1785118356697776128
author Mehta, Saumya
Selvaganesh, Sahana
Nesappan, Thiyaneswaran
Veeraraghavan, Vishnu Priya
Sathishkumar, Palanivel
Eswaramoorthy, Rajalakshmanan
author_facet Mehta, Saumya
Selvaganesh, Sahana
Nesappan, Thiyaneswaran
Veeraraghavan, Vishnu Priya
Sathishkumar, Palanivel
Eswaramoorthy, Rajalakshmanan
author_sort Mehta, Saumya
collection PubMed
description With the advent of various implant abutment junctions, the ultimate aim is to develop a precise implant abutment junction with negligible micro-leakage. However precise the mechanical connection is, there seems to be a negligible amount of micro-leakage that is present that can be addressed with the help of sealing gel. This study aims to assess the micro-leakage between the neo-sealing gel and the commercially available implant sealing gel. The study was conducted on implants (n=15) with internal hex connections, group 1 (No gel, n=5), group 2 (Neo gel, n=5) and group 3 (commercial gel, n=5). Mean dE*ab values of 0.28± 0.02, 0.04± 0.01 and 0.17±0.01 were noted for the 3 groups, and there was statistically significant difference between the 3 groups (p≤0.05). The study suggests that the neo sealing gel may be a promising material to prevent bacterial ingress and micro-leakage at the implant abutment junction.
format Online
Article
Text
id pubmed-10563552
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Biomedical Informatics
record_format MEDLINE/PubMed
spelling pubmed-105635522023-10-11 Evaluation of neo-implant abutment junction sealing gel among Indian patients Mehta, Saumya Selvaganesh, Sahana Nesappan, Thiyaneswaran Veeraraghavan, Vishnu Priya Sathishkumar, Palanivel Eswaramoorthy, Rajalakshmanan Bioinformation Research Article With the advent of various implant abutment junctions, the ultimate aim is to develop a precise implant abutment junction with negligible micro-leakage. However precise the mechanical connection is, there seems to be a negligible amount of micro-leakage that is present that can be addressed with the help of sealing gel. This study aims to assess the micro-leakage between the neo-sealing gel and the commercially available implant sealing gel. The study was conducted on implants (n=15) with internal hex connections, group 1 (No gel, n=5), group 2 (Neo gel, n=5) and group 3 (commercial gel, n=5). Mean dE*ab values of 0.28± 0.02, 0.04± 0.01 and 0.17±0.01 were noted for the 3 groups, and there was statistically significant difference between the 3 groups (p≤0.05). The study suggests that the neo sealing gel may be a promising material to prevent bacterial ingress and micro-leakage at the implant abutment junction. Biomedical Informatics 2023-04-30 /pmc/articles/PMC10563552/ /pubmed/37822813 http://dx.doi.org/10.6026/97320630019502 Text en © 2023 Biomedical Informatics https://creativecommons.org/licenses/by/3.0/This is an Open Access article which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. This is distributed under the terms of the Creative Commons Attribution License.
spellingShingle Research Article
Mehta, Saumya
Selvaganesh, Sahana
Nesappan, Thiyaneswaran
Veeraraghavan, Vishnu Priya
Sathishkumar, Palanivel
Eswaramoorthy, Rajalakshmanan
Evaluation of neo-implant abutment junction sealing gel among Indian patients
title Evaluation of neo-implant abutment junction sealing gel among Indian patients
title_full Evaluation of neo-implant abutment junction sealing gel among Indian patients
title_fullStr Evaluation of neo-implant abutment junction sealing gel among Indian patients
title_full_unstemmed Evaluation of neo-implant abutment junction sealing gel among Indian patients
title_short Evaluation of neo-implant abutment junction sealing gel among Indian patients
title_sort evaluation of neo-implant abutment junction sealing gel among indian patients
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10563552/
https://www.ncbi.nlm.nih.gov/pubmed/37822813
http://dx.doi.org/10.6026/97320630019502
work_keys_str_mv AT mehtasaumya evaluationofneoimplantabutmentjunctionsealinggelamongindianpatients
AT selvaganeshsahana evaluationofneoimplantabutmentjunctionsealinggelamongindianpatients
AT nesappanthiyaneswaran evaluationofneoimplantabutmentjunctionsealinggelamongindianpatients
AT veeraraghavanvishnupriya evaluationofneoimplantabutmentjunctionsealinggelamongindianpatients
AT sathishkumarpalanivel evaluationofneoimplantabutmentjunctionsealinggelamongindianpatients
AT eswaramoorthyrajalakshmanan evaluationofneoimplantabutmentjunctionsealinggelamongindianpatients