Cargando…

The evaluation of cardiac functions in deep Trendelenburg position during robotic-assisted laparoscopic prostatectomy

OBJECTIVE: This study aimed to demonstrate the reliability of the cardiac cycle efficiency value through its correlation with longitudinal strain by observing the effect of the deep Trendelenburg position. DESIGN: A prospective, observational study. SETTING: Single center. PARTICIPANTS: Between May...

Descripción completa

Detalles Bibliográficos
Autores principales: Kılınç, Emir, Yildirim, Serap Aktas, Ulugöl, Halim, Büyüköner, Elif Eroğlu, Güçyetmez, Bülent, Toraman, Fevzi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10563763/
https://www.ncbi.nlm.nih.gov/pubmed/37822468
http://dx.doi.org/10.3389/fmed.2023.1273180
_version_ 1785118404891377664
author Kılınç, Emir
Yildirim, Serap Aktas
Ulugöl, Halim
Büyüköner, Elif Eroğlu
Güçyetmez, Bülent
Toraman, Fevzi
author_facet Kılınç, Emir
Yildirim, Serap Aktas
Ulugöl, Halim
Büyüköner, Elif Eroğlu
Güçyetmez, Bülent
Toraman, Fevzi
author_sort Kılınç, Emir
collection PubMed
description OBJECTIVE: This study aimed to demonstrate the reliability of the cardiac cycle efficiency value through its correlation with longitudinal strain by observing the effect of the deep Trendelenburg position. DESIGN: A prospective, observational study. SETTING: Single center. PARTICIPANTS: Between May and September 2022, the hemodynamic parameters of 30 patients who underwent robotic assisted laparoscopic prostatectomy under general anesthesia were prospectively evaluated. MEASUREMENTS AND MAIN RESULTS: All invasive cardiac monitoring parameters and longitudinal strain achieved transesophageal echocardiography were recorded in pre-deep Trendelenburg position (T3) and 10th minute of deep Trendelenburg position (T4). Delta values were calculated for the cardiac cycle efficiency and longitudinal strain (values at T4 minus values at T3). The estimated power was calculated as 0.99 in accordance with the cardiac cycle efficiency values at T3 and T4 (effect size: 0.85 standard deviations of the mean difference: 0.22, alpha: 0.05). At T4, heart rate, pulse pressure variation, cardiac cycle efficiency, dP/dt and longitudinal strain were significantly lower than those at T3 (p = 0.009, p < 0.001, p < 0.001, and p < 0.001, respectively). There was a positive correlation between the delta-cardiac cycle efficiency and delta-longitudinal strain (R(2) = 0.36, p < 0.001). CONCLUSION: Although the absence of significant changes in mean arterial pressure and cardiac index after Trendelenburg position suggests that cardiac workload has not changed, changes in cardiac cycle efficiency and longitudinal strain indicate increased cardiac workload due to increased ventriculo-arterial coupling.
format Online
Article
Text
id pubmed-10563763
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-105637632023-10-11 The evaluation of cardiac functions in deep Trendelenburg position during robotic-assisted laparoscopic prostatectomy Kılınç, Emir Yildirim, Serap Aktas Ulugöl, Halim Büyüköner, Elif Eroğlu Güçyetmez, Bülent Toraman, Fevzi Front Med (Lausanne) Medicine OBJECTIVE: This study aimed to demonstrate the reliability of the cardiac cycle efficiency value through its correlation with longitudinal strain by observing the effect of the deep Trendelenburg position. DESIGN: A prospective, observational study. SETTING: Single center. PARTICIPANTS: Between May and September 2022, the hemodynamic parameters of 30 patients who underwent robotic assisted laparoscopic prostatectomy under general anesthesia were prospectively evaluated. MEASUREMENTS AND MAIN RESULTS: All invasive cardiac monitoring parameters and longitudinal strain achieved transesophageal echocardiography were recorded in pre-deep Trendelenburg position (T3) and 10th minute of deep Trendelenburg position (T4). Delta values were calculated for the cardiac cycle efficiency and longitudinal strain (values at T4 minus values at T3). The estimated power was calculated as 0.99 in accordance with the cardiac cycle efficiency values at T3 and T4 (effect size: 0.85 standard deviations of the mean difference: 0.22, alpha: 0.05). At T4, heart rate, pulse pressure variation, cardiac cycle efficiency, dP/dt and longitudinal strain were significantly lower than those at T3 (p = 0.009, p < 0.001, p < 0.001, and p < 0.001, respectively). There was a positive correlation between the delta-cardiac cycle efficiency and delta-longitudinal strain (R(2) = 0.36, p < 0.001). CONCLUSION: Although the absence of significant changes in mean arterial pressure and cardiac index after Trendelenburg position suggests that cardiac workload has not changed, changes in cardiac cycle efficiency and longitudinal strain indicate increased cardiac workload due to increased ventriculo-arterial coupling. Frontiers Media S.A. 2023-09-25 /pmc/articles/PMC10563763/ /pubmed/37822468 http://dx.doi.org/10.3389/fmed.2023.1273180 Text en Copyright © 2023 Kılınç, Yildirim, Ulugöl, Büyüköner, Güçyetmez and Toraman. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Medicine
Kılınç, Emir
Yildirim, Serap Aktas
Ulugöl, Halim
Büyüköner, Elif Eroğlu
Güçyetmez, Bülent
Toraman, Fevzi
The evaluation of cardiac functions in deep Trendelenburg position during robotic-assisted laparoscopic prostatectomy
title The evaluation of cardiac functions in deep Trendelenburg position during robotic-assisted laparoscopic prostatectomy
title_full The evaluation of cardiac functions in deep Trendelenburg position during robotic-assisted laparoscopic prostatectomy
title_fullStr The evaluation of cardiac functions in deep Trendelenburg position during robotic-assisted laparoscopic prostatectomy
title_full_unstemmed The evaluation of cardiac functions in deep Trendelenburg position during robotic-assisted laparoscopic prostatectomy
title_short The evaluation of cardiac functions in deep Trendelenburg position during robotic-assisted laparoscopic prostatectomy
title_sort evaluation of cardiac functions in deep trendelenburg position during robotic-assisted laparoscopic prostatectomy
topic Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10563763/
https://www.ncbi.nlm.nih.gov/pubmed/37822468
http://dx.doi.org/10.3389/fmed.2023.1273180
work_keys_str_mv AT kılıncemir theevaluationofcardiacfunctionsindeeptrendelenburgpositionduringroboticassistedlaparoscopicprostatectomy
AT yildirimserapaktas theevaluationofcardiacfunctionsindeeptrendelenburgpositionduringroboticassistedlaparoscopicprostatectomy
AT ulugolhalim theevaluationofcardiacfunctionsindeeptrendelenburgpositionduringroboticassistedlaparoscopicprostatectomy
AT buyukonereliferoglu theevaluationofcardiacfunctionsindeeptrendelenburgpositionduringroboticassistedlaparoscopicprostatectomy
AT gucyetmezbulent theevaluationofcardiacfunctionsindeeptrendelenburgpositionduringroboticassistedlaparoscopicprostatectomy
AT toramanfevzi theevaluationofcardiacfunctionsindeeptrendelenburgpositionduringroboticassistedlaparoscopicprostatectomy
AT kılıncemir evaluationofcardiacfunctionsindeeptrendelenburgpositionduringroboticassistedlaparoscopicprostatectomy
AT yildirimserapaktas evaluationofcardiacfunctionsindeeptrendelenburgpositionduringroboticassistedlaparoscopicprostatectomy
AT ulugolhalim evaluationofcardiacfunctionsindeeptrendelenburgpositionduringroboticassistedlaparoscopicprostatectomy
AT buyukonereliferoglu evaluationofcardiacfunctionsindeeptrendelenburgpositionduringroboticassistedlaparoscopicprostatectomy
AT gucyetmezbulent evaluationofcardiacfunctionsindeeptrendelenburgpositionduringroboticassistedlaparoscopicprostatectomy
AT toramanfevzi evaluationofcardiacfunctionsindeeptrendelenburgpositionduringroboticassistedlaparoscopicprostatectomy