Cargando…
The evaluation of cardiac functions in deep Trendelenburg position during robotic-assisted laparoscopic prostatectomy
OBJECTIVE: This study aimed to demonstrate the reliability of the cardiac cycle efficiency value through its correlation with longitudinal strain by observing the effect of the deep Trendelenburg position. DESIGN: A prospective, observational study. SETTING: Single center. PARTICIPANTS: Between May...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10563763/ https://www.ncbi.nlm.nih.gov/pubmed/37822468 http://dx.doi.org/10.3389/fmed.2023.1273180 |
_version_ | 1785118404891377664 |
---|---|
author | Kılınç, Emir Yildirim, Serap Aktas Ulugöl, Halim Büyüköner, Elif Eroğlu Güçyetmez, Bülent Toraman, Fevzi |
author_facet | Kılınç, Emir Yildirim, Serap Aktas Ulugöl, Halim Büyüköner, Elif Eroğlu Güçyetmez, Bülent Toraman, Fevzi |
author_sort | Kılınç, Emir |
collection | PubMed |
description | OBJECTIVE: This study aimed to demonstrate the reliability of the cardiac cycle efficiency value through its correlation with longitudinal strain by observing the effect of the deep Trendelenburg position. DESIGN: A prospective, observational study. SETTING: Single center. PARTICIPANTS: Between May and September 2022, the hemodynamic parameters of 30 patients who underwent robotic assisted laparoscopic prostatectomy under general anesthesia were prospectively evaluated. MEASUREMENTS AND MAIN RESULTS: All invasive cardiac monitoring parameters and longitudinal strain achieved transesophageal echocardiography were recorded in pre-deep Trendelenburg position (T3) and 10th minute of deep Trendelenburg position (T4). Delta values were calculated for the cardiac cycle efficiency and longitudinal strain (values at T4 minus values at T3). The estimated power was calculated as 0.99 in accordance with the cardiac cycle efficiency values at T3 and T4 (effect size: 0.85 standard deviations of the mean difference: 0.22, alpha: 0.05). At T4, heart rate, pulse pressure variation, cardiac cycle efficiency, dP/dt and longitudinal strain were significantly lower than those at T3 (p = 0.009, p < 0.001, p < 0.001, and p < 0.001, respectively). There was a positive correlation between the delta-cardiac cycle efficiency and delta-longitudinal strain (R(2) = 0.36, p < 0.001). CONCLUSION: Although the absence of significant changes in mean arterial pressure and cardiac index after Trendelenburg position suggests that cardiac workload has not changed, changes in cardiac cycle efficiency and longitudinal strain indicate increased cardiac workload due to increased ventriculo-arterial coupling. |
format | Online Article Text |
id | pubmed-10563763 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-105637632023-10-11 The evaluation of cardiac functions in deep Trendelenburg position during robotic-assisted laparoscopic prostatectomy Kılınç, Emir Yildirim, Serap Aktas Ulugöl, Halim Büyüköner, Elif Eroğlu Güçyetmez, Bülent Toraman, Fevzi Front Med (Lausanne) Medicine OBJECTIVE: This study aimed to demonstrate the reliability of the cardiac cycle efficiency value through its correlation with longitudinal strain by observing the effect of the deep Trendelenburg position. DESIGN: A prospective, observational study. SETTING: Single center. PARTICIPANTS: Between May and September 2022, the hemodynamic parameters of 30 patients who underwent robotic assisted laparoscopic prostatectomy under general anesthesia were prospectively evaluated. MEASUREMENTS AND MAIN RESULTS: All invasive cardiac monitoring parameters and longitudinal strain achieved transesophageal echocardiography were recorded in pre-deep Trendelenburg position (T3) and 10th minute of deep Trendelenburg position (T4). Delta values were calculated for the cardiac cycle efficiency and longitudinal strain (values at T4 minus values at T3). The estimated power was calculated as 0.99 in accordance with the cardiac cycle efficiency values at T3 and T4 (effect size: 0.85 standard deviations of the mean difference: 0.22, alpha: 0.05). At T4, heart rate, pulse pressure variation, cardiac cycle efficiency, dP/dt and longitudinal strain were significantly lower than those at T3 (p = 0.009, p < 0.001, p < 0.001, and p < 0.001, respectively). There was a positive correlation between the delta-cardiac cycle efficiency and delta-longitudinal strain (R(2) = 0.36, p < 0.001). CONCLUSION: Although the absence of significant changes in mean arterial pressure and cardiac index after Trendelenburg position suggests that cardiac workload has not changed, changes in cardiac cycle efficiency and longitudinal strain indicate increased cardiac workload due to increased ventriculo-arterial coupling. Frontiers Media S.A. 2023-09-25 /pmc/articles/PMC10563763/ /pubmed/37822468 http://dx.doi.org/10.3389/fmed.2023.1273180 Text en Copyright © 2023 Kılınç, Yildirim, Ulugöl, Büyüköner, Güçyetmez and Toraman. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Medicine Kılınç, Emir Yildirim, Serap Aktas Ulugöl, Halim Büyüköner, Elif Eroğlu Güçyetmez, Bülent Toraman, Fevzi The evaluation of cardiac functions in deep Trendelenburg position during robotic-assisted laparoscopic prostatectomy |
title | The evaluation of cardiac functions in deep Trendelenburg position during robotic-assisted laparoscopic prostatectomy |
title_full | The evaluation of cardiac functions in deep Trendelenburg position during robotic-assisted laparoscopic prostatectomy |
title_fullStr | The evaluation of cardiac functions in deep Trendelenburg position during robotic-assisted laparoscopic prostatectomy |
title_full_unstemmed | The evaluation of cardiac functions in deep Trendelenburg position during robotic-assisted laparoscopic prostatectomy |
title_short | The evaluation of cardiac functions in deep Trendelenburg position during robotic-assisted laparoscopic prostatectomy |
title_sort | evaluation of cardiac functions in deep trendelenburg position during robotic-assisted laparoscopic prostatectomy |
topic | Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10563763/ https://www.ncbi.nlm.nih.gov/pubmed/37822468 http://dx.doi.org/10.3389/fmed.2023.1273180 |
work_keys_str_mv | AT kılıncemir theevaluationofcardiacfunctionsindeeptrendelenburgpositionduringroboticassistedlaparoscopicprostatectomy AT yildirimserapaktas theevaluationofcardiacfunctionsindeeptrendelenburgpositionduringroboticassistedlaparoscopicprostatectomy AT ulugolhalim theevaluationofcardiacfunctionsindeeptrendelenburgpositionduringroboticassistedlaparoscopicprostatectomy AT buyukonereliferoglu theevaluationofcardiacfunctionsindeeptrendelenburgpositionduringroboticassistedlaparoscopicprostatectomy AT gucyetmezbulent theevaluationofcardiacfunctionsindeeptrendelenburgpositionduringroboticassistedlaparoscopicprostatectomy AT toramanfevzi theevaluationofcardiacfunctionsindeeptrendelenburgpositionduringroboticassistedlaparoscopicprostatectomy AT kılıncemir evaluationofcardiacfunctionsindeeptrendelenburgpositionduringroboticassistedlaparoscopicprostatectomy AT yildirimserapaktas evaluationofcardiacfunctionsindeeptrendelenburgpositionduringroboticassistedlaparoscopicprostatectomy AT ulugolhalim evaluationofcardiacfunctionsindeeptrendelenburgpositionduringroboticassistedlaparoscopicprostatectomy AT buyukonereliferoglu evaluationofcardiacfunctionsindeeptrendelenburgpositionduringroboticassistedlaparoscopicprostatectomy AT gucyetmezbulent evaluationofcardiacfunctionsindeeptrendelenburgpositionduringroboticassistedlaparoscopicprostatectomy AT toramanfevzi evaluationofcardiacfunctionsindeeptrendelenburgpositionduringroboticassistedlaparoscopicprostatectomy |