Cargando…

Development of a perfusable, hierarchical microvasculature-on-a-chip model

Several methods have been developed for generating 3D, in vitro, organ-on-chip models of human vasculature to study vascular function, transport, and tissue engineering. However, many of these existing models lack the hierarchical nature of the arterial-to-capillary-to-venous architecture that is ke...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Sophia W., Blazeski, Adriana, Zhang, Shun, Shelton, Sarah E., Offeddu, Giovanni S., Kamm, Roger D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10563829/
https://www.ncbi.nlm.nih.gov/pubmed/37771308
http://dx.doi.org/10.1039/d3lc00512g
_version_ 1785118418248138752
author Chen, Sophia W.
Blazeski, Adriana
Zhang, Shun
Shelton, Sarah E.
Offeddu, Giovanni S.
Kamm, Roger D.
author_facet Chen, Sophia W.
Blazeski, Adriana
Zhang, Shun
Shelton, Sarah E.
Offeddu, Giovanni S.
Kamm, Roger D.
author_sort Chen, Sophia W.
collection PubMed
description Several methods have been developed for generating 3D, in vitro, organ-on-chip models of human vasculature to study vascular function, transport, and tissue engineering. However, many of these existing models lack the hierarchical nature of the arterial-to-capillary-to-venous architecture that is key to capturing a more comprehensive view of the human microvasculature. Here, we present a perfusable, multi-compartmental model that recapitulates the three microvascular compartments to assess various physiological properties such as vessel permeability, vasoconstriction dynamics, and circulating cell arrest and extravasation. Viscous finger patterning and passive pumping create the larger arterial and venular lumens, while the smaller diameter capillary bed vessels are generated through self-assembly. These compartments anastomose and form a perfusable, hierarchical system that portrays the directionality of blood flow through the microvasculature. The addition of collagen channels reduces the apparent permeability of the central capillary region, likely by reducing leakage from the side channels, enabling more accurate measurements of vascular permeability—an important motivation for this study. Furthermore, the model permits modulation of fluid flow and shear stress conditions throughout the system by using hydrostatic pressure heads to apply pressure differentials across either the arteriole or the capillary. This is a pertinent system for modeling circulating tumor or T cell dissemination and extravasation. Circulating cells were found to arrest in areas conducive to physical trapping or areas with the least amount of shear stress, consistent with hemodynamic or mechanical theories of metastasis. Overall, this model captures more features of human microvascular beds and is capable of testing a broad variety of hypotheses.
format Online
Article
Text
id pubmed-10563829
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-105638292023-10-11 Development of a perfusable, hierarchical microvasculature-on-a-chip model Chen, Sophia W. Blazeski, Adriana Zhang, Shun Shelton, Sarah E. Offeddu, Giovanni S. Kamm, Roger D. Lab Chip Chemistry Several methods have been developed for generating 3D, in vitro, organ-on-chip models of human vasculature to study vascular function, transport, and tissue engineering. However, many of these existing models lack the hierarchical nature of the arterial-to-capillary-to-venous architecture that is key to capturing a more comprehensive view of the human microvasculature. Here, we present a perfusable, multi-compartmental model that recapitulates the three microvascular compartments to assess various physiological properties such as vessel permeability, vasoconstriction dynamics, and circulating cell arrest and extravasation. Viscous finger patterning and passive pumping create the larger arterial and venular lumens, while the smaller diameter capillary bed vessels are generated through self-assembly. These compartments anastomose and form a perfusable, hierarchical system that portrays the directionality of blood flow through the microvasculature. The addition of collagen channels reduces the apparent permeability of the central capillary region, likely by reducing leakage from the side channels, enabling more accurate measurements of vascular permeability—an important motivation for this study. Furthermore, the model permits modulation of fluid flow and shear stress conditions throughout the system by using hydrostatic pressure heads to apply pressure differentials across either the arteriole or the capillary. This is a pertinent system for modeling circulating tumor or T cell dissemination and extravasation. Circulating cells were found to arrest in areas conducive to physical trapping or areas with the least amount of shear stress, consistent with hemodynamic or mechanical theories of metastasis. Overall, this model captures more features of human microvascular beds and is capable of testing a broad variety of hypotheses. The Royal Society of Chemistry 2023-09-19 /pmc/articles/PMC10563829/ /pubmed/37771308 http://dx.doi.org/10.1039/d3lc00512g Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by-nc/3.0/
spellingShingle Chemistry
Chen, Sophia W.
Blazeski, Adriana
Zhang, Shun
Shelton, Sarah E.
Offeddu, Giovanni S.
Kamm, Roger D.
Development of a perfusable, hierarchical microvasculature-on-a-chip model
title Development of a perfusable, hierarchical microvasculature-on-a-chip model
title_full Development of a perfusable, hierarchical microvasculature-on-a-chip model
title_fullStr Development of a perfusable, hierarchical microvasculature-on-a-chip model
title_full_unstemmed Development of a perfusable, hierarchical microvasculature-on-a-chip model
title_short Development of a perfusable, hierarchical microvasculature-on-a-chip model
title_sort development of a perfusable, hierarchical microvasculature-on-a-chip model
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10563829/
https://www.ncbi.nlm.nih.gov/pubmed/37771308
http://dx.doi.org/10.1039/d3lc00512g
work_keys_str_mv AT chensophiaw developmentofaperfusablehierarchicalmicrovasculatureonachipmodel
AT blazeskiadriana developmentofaperfusablehierarchicalmicrovasculatureonachipmodel
AT zhangshun developmentofaperfusablehierarchicalmicrovasculatureonachipmodel
AT sheltonsarahe developmentofaperfusablehierarchicalmicrovasculatureonachipmodel
AT offeddugiovannis developmentofaperfusablehierarchicalmicrovasculatureonachipmodel
AT kammrogerd developmentofaperfusablehierarchicalmicrovasculatureonachipmodel