Cargando…
An approach to reduce Descemet’s membrane scrolling: Relevance to Descemet’s membrane endothelial keratoplasty (DMEK)
PURPOSE: We aimed to determine whether Descemet’s membrane (DM) scrolling occurs primarily along the vertical or horizontal axis and establish whether oval trephination along the axis of least scrolling can reduce the grade of the scroll. METHODS: The longest limbus-to-limbus axis on 28 sclerocornea...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10565912/ https://www.ncbi.nlm.nih.gov/pubmed/37602605 http://dx.doi.org/10.4103/IJO.IJO_1531_23 |
_version_ | 1785118802140200960 |
---|---|
author | Dua, Harminder S Freitas, Rui Sadek, Youssef Ting, Darren SJ Nubile, Mario Mohammed, Imran Said, Dalia G |
author_facet | Dua, Harminder S Freitas, Rui Sadek, Youssef Ting, Darren SJ Nubile, Mario Mohammed, Imran Said, Dalia G |
author_sort | Dua, Harminder S |
collection | PubMed |
description | PURPOSE: We aimed to determine whether Descemet’s membrane (DM) scrolling occurs primarily along the vertical or horizontal axis and establish whether oval trephination along the axis of least scrolling can reduce the grade of the scroll. METHODS: The longest limbus-to-limbus axis on 28 sclerocorneal discs was taken as the horizontal axis. The horizontal (n = 7) or (right angles to it) vertical (n = 6) axis was marked on DM before peeling it off. The direction and grade of scrolling was observed. Narrow strips (3–4 mm wide) were then cut along the two axes (n = 4 each) and the scrolling pattern was observed. Ellipses (7 × 9 mm) of DM were punched along the two axes (n = 6 each) and the scrolls graded. Immunofluorescent staining for elastin on horizontal and vertical tissue sections from three DM samples was performed. The intensity and thickness of elastin staining were measured. RESULTS: Twenty-four (85.72%) DM samples showed scrolling along the horizontal axis, none showed scrolling along the vertical axis, and four (14.28%) samples showed a spiral scroll, regardless of which axis was marked (grade 3.7 and 3.6). Vertically oval discs showed significantly reduced scrolling (grade 1.2) compared to horizontally oval discs (grade 3.5). Narrow strips of DM showed a similar scrolling pattern. Immunohistology showed no difference in any of the parameters examined along the two axes or from the center to the periphery. CONCLUSION: DM scrolls primarily along the horizontal axis. Vertically oval DM samples show minimal scrolling, which can be an advantage in DMEK. Differential scrolling is not determined by the distribution of elastin. |
format | Online Article Text |
id | pubmed-10565912 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-105659122023-10-12 An approach to reduce Descemet’s membrane scrolling: Relevance to Descemet’s membrane endothelial keratoplasty (DMEK) Dua, Harminder S Freitas, Rui Sadek, Youssef Ting, Darren SJ Nubile, Mario Mohammed, Imran Said, Dalia G Indian J Ophthalmol Original Article PURPOSE: We aimed to determine whether Descemet’s membrane (DM) scrolling occurs primarily along the vertical or horizontal axis and establish whether oval trephination along the axis of least scrolling can reduce the grade of the scroll. METHODS: The longest limbus-to-limbus axis on 28 sclerocorneal discs was taken as the horizontal axis. The horizontal (n = 7) or (right angles to it) vertical (n = 6) axis was marked on DM before peeling it off. The direction and grade of scrolling was observed. Narrow strips (3–4 mm wide) were then cut along the two axes (n = 4 each) and the scrolling pattern was observed. Ellipses (7 × 9 mm) of DM were punched along the two axes (n = 6 each) and the scrolls graded. Immunofluorescent staining for elastin on horizontal and vertical tissue sections from three DM samples was performed. The intensity and thickness of elastin staining were measured. RESULTS: Twenty-four (85.72%) DM samples showed scrolling along the horizontal axis, none showed scrolling along the vertical axis, and four (14.28%) samples showed a spiral scroll, regardless of which axis was marked (grade 3.7 and 3.6). Vertically oval discs showed significantly reduced scrolling (grade 1.2) compared to horizontally oval discs (grade 3.5). Narrow strips of DM showed a similar scrolling pattern. Immunohistology showed no difference in any of the parameters examined along the two axes or from the center to the periphery. CONCLUSION: DM scrolls primarily along the horizontal axis. Vertically oval DM samples show minimal scrolling, which can be an advantage in DMEK. Differential scrolling is not determined by the distribution of elastin. Wolters Kluwer - Medknow 2023-09 2023-08-21 /pmc/articles/PMC10565912/ /pubmed/37602605 http://dx.doi.org/10.4103/IJO.IJO_1531_23 Text en Copyright: © 2023 Indian Journal of Ophthalmology https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Dua, Harminder S Freitas, Rui Sadek, Youssef Ting, Darren SJ Nubile, Mario Mohammed, Imran Said, Dalia G An approach to reduce Descemet’s membrane scrolling: Relevance to Descemet’s membrane endothelial keratoplasty (DMEK) |
title | An approach to reduce Descemet’s membrane scrolling: Relevance to Descemet’s membrane endothelial keratoplasty (DMEK) |
title_full | An approach to reduce Descemet’s membrane scrolling: Relevance to Descemet’s membrane endothelial keratoplasty (DMEK) |
title_fullStr | An approach to reduce Descemet’s membrane scrolling: Relevance to Descemet’s membrane endothelial keratoplasty (DMEK) |
title_full_unstemmed | An approach to reduce Descemet’s membrane scrolling: Relevance to Descemet’s membrane endothelial keratoplasty (DMEK) |
title_short | An approach to reduce Descemet’s membrane scrolling: Relevance to Descemet’s membrane endothelial keratoplasty (DMEK) |
title_sort | approach to reduce descemet’s membrane scrolling: relevance to descemet’s membrane endothelial keratoplasty (dmek) |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10565912/ https://www.ncbi.nlm.nih.gov/pubmed/37602605 http://dx.doi.org/10.4103/IJO.IJO_1531_23 |
work_keys_str_mv | AT duaharminders anapproachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT freitasrui anapproachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT sadekyoussef anapproachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT tingdarrensj anapproachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT nubilemario anapproachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT mohammedimran anapproachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT saiddaliag anapproachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT duaharminders approachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT freitasrui approachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT sadekyoussef approachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT tingdarrensj approachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT nubilemario approachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT mohammedimran approachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek AT saiddaliag approachtoreducedescemetsmembranescrollingrelevancetodescemetsmembraneendothelialkeratoplastydmek |