Cargando…
Comparison of intraocular lens power prediction accuracy of formulas in American Society of Cataract and Refractive Surgery post-refractive surgery calculator in eyes with prior radial keratotomy
PURPOSE: To evaluate the accuracy of intraocular lens (IOL) power prediction of the formulas available on the American Society of Cataract and Refractive Surgery (ASCRS) post-refractive calculator in eyes with prior radial keratotomy (RK) for myopia. METHODS: This retrospective study included 25 eye...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10565947/ https://www.ncbi.nlm.nih.gov/pubmed/37602612 http://dx.doi.org/10.4103/IJO.IJO_3417_22 |
_version_ | 1785118810314899456 |
---|---|
author | Shetty, Naren Sathe, Priyanka Aishwarya Francis, Mathew Shetty, Rohit |
author_facet | Shetty, Naren Sathe, Priyanka Aishwarya Francis, Mathew Shetty, Rohit |
author_sort | Shetty, Naren |
collection | PubMed |
description | PURPOSE: To evaluate the accuracy of intraocular lens (IOL) power prediction of the formulas available on the American Society of Cataract and Refractive Surgery (ASCRS) post-refractive calculator in eyes with prior radial keratotomy (RK) for myopia. METHODS: This retrospective study included 25 eyes of 18 patients whose status was post-RK for treatment of myopia, which had undergone cataract extraction with IOL implantation. Prediction error was calculated as the difference between implanted IOL power and predicted power by various formulae available on ASCRS post-refractive calculator. The formulas compared were Humphrey Atlas method, IOLMaster/Lenstar method, Barrett True-K no-history formula, ASCRS Average power, and ASCRS Maximum power on ASCRS post-refractive calculator. RESULTS: Median absolute errors were the least for Barrett True-K and ASCRS Maximum power, that is, 0.56 (0.25, 1.04) and 0.56 (0.25, 1.06) D, respectively, and that of Atlas method was 1.60 (0.85, 2.28) D. Median arithmetic errors were positive for Atlas, Barrett True-K, ASCRS Average (0.86 [−0.17, 1.61], 0.14 [−0.22 to 0.54], and 0.23 [−0.054, 0.76] D, respectively) and negative for IOLMaster/Lenstar method and ASCRS Maximum power (−0.02 [−0.46 to 0.38] and − 0.48 [−1.06 to − 0.22] D, respectively). Multiple comparison analysis of Friedman’s test revealed that Atlas formula was significantly different from IOLMaster/Lenstar, Barrett True-K, and ASCRS Maximum power; ASCRS Maximum power was significantly different from all others (P < 0.00001). CONCLUSION: In post-RK eyes, Barrett True-K no-history formula and ASCRS Maximum power given by the ASCRS calculator were more accurate than other available formulas, with ASCRS Maximum leading to more myopic outcomes when compared to others. |
format | Online Article Text |
id | pubmed-10565947 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-105659472023-10-12 Comparison of intraocular lens power prediction accuracy of formulas in American Society of Cataract and Refractive Surgery post-refractive surgery calculator in eyes with prior radial keratotomy Shetty, Naren Sathe, Priyanka Aishwarya Francis, Mathew Shetty, Rohit Indian J Ophthalmol Original Article PURPOSE: To evaluate the accuracy of intraocular lens (IOL) power prediction of the formulas available on the American Society of Cataract and Refractive Surgery (ASCRS) post-refractive calculator in eyes with prior radial keratotomy (RK) for myopia. METHODS: This retrospective study included 25 eyes of 18 patients whose status was post-RK for treatment of myopia, which had undergone cataract extraction with IOL implantation. Prediction error was calculated as the difference between implanted IOL power and predicted power by various formulae available on ASCRS post-refractive calculator. The formulas compared were Humphrey Atlas method, IOLMaster/Lenstar method, Barrett True-K no-history formula, ASCRS Average power, and ASCRS Maximum power on ASCRS post-refractive calculator. RESULTS: Median absolute errors were the least for Barrett True-K and ASCRS Maximum power, that is, 0.56 (0.25, 1.04) and 0.56 (0.25, 1.06) D, respectively, and that of Atlas method was 1.60 (0.85, 2.28) D. Median arithmetic errors were positive for Atlas, Barrett True-K, ASCRS Average (0.86 [−0.17, 1.61], 0.14 [−0.22 to 0.54], and 0.23 [−0.054, 0.76] D, respectively) and negative for IOLMaster/Lenstar method and ASCRS Maximum power (−0.02 [−0.46 to 0.38] and − 0.48 [−1.06 to − 0.22] D, respectively). Multiple comparison analysis of Friedman’s test revealed that Atlas formula was significantly different from IOLMaster/Lenstar, Barrett True-K, and ASCRS Maximum power; ASCRS Maximum power was significantly different from all others (P < 0.00001). CONCLUSION: In post-RK eyes, Barrett True-K no-history formula and ASCRS Maximum power given by the ASCRS calculator were more accurate than other available formulas, with ASCRS Maximum leading to more myopic outcomes when compared to others. Wolters Kluwer - Medknow 2023-09 2023-08-21 /pmc/articles/PMC10565947/ /pubmed/37602612 http://dx.doi.org/10.4103/IJO.IJO_3417_22 Text en Copyright: © 2023 Indian Journal of Ophthalmology https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Shetty, Naren Sathe, Priyanka Aishwarya Francis, Mathew Shetty, Rohit Comparison of intraocular lens power prediction accuracy of formulas in American Society of Cataract and Refractive Surgery post-refractive surgery calculator in eyes with prior radial keratotomy |
title | Comparison of intraocular lens power prediction accuracy of formulas in American Society of Cataract and Refractive Surgery post-refractive surgery calculator in eyes with prior radial keratotomy |
title_full | Comparison of intraocular lens power prediction accuracy of formulas in American Society of Cataract and Refractive Surgery post-refractive surgery calculator in eyes with prior radial keratotomy |
title_fullStr | Comparison of intraocular lens power prediction accuracy of formulas in American Society of Cataract and Refractive Surgery post-refractive surgery calculator in eyes with prior radial keratotomy |
title_full_unstemmed | Comparison of intraocular lens power prediction accuracy of formulas in American Society of Cataract and Refractive Surgery post-refractive surgery calculator in eyes with prior radial keratotomy |
title_short | Comparison of intraocular lens power prediction accuracy of formulas in American Society of Cataract and Refractive Surgery post-refractive surgery calculator in eyes with prior radial keratotomy |
title_sort | comparison of intraocular lens power prediction accuracy of formulas in american society of cataract and refractive surgery post-refractive surgery calculator in eyes with prior radial keratotomy |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10565947/ https://www.ncbi.nlm.nih.gov/pubmed/37602612 http://dx.doi.org/10.4103/IJO.IJO_3417_22 |
work_keys_str_mv | AT shettynaren comparisonofintraocularlenspowerpredictionaccuracyofformulasinamericansocietyofcataractandrefractivesurgerypostrefractivesurgerycalculatorineyeswithpriorradialkeratotomy AT sathepriyanka comparisonofintraocularlenspowerpredictionaccuracyofformulasinamericansocietyofcataractandrefractivesurgerypostrefractivesurgerycalculatorineyeswithpriorradialkeratotomy AT aishwarya comparisonofintraocularlenspowerpredictionaccuracyofformulasinamericansocietyofcataractandrefractivesurgerypostrefractivesurgerycalculatorineyeswithpriorradialkeratotomy AT francismathew comparisonofintraocularlenspowerpredictionaccuracyofformulasinamericansocietyofcataractandrefractivesurgerypostrefractivesurgerycalculatorineyeswithpriorradialkeratotomy AT shettyrohit comparisonofintraocularlenspowerpredictionaccuracyofformulasinamericansocietyofcataractandrefractivesurgerypostrefractivesurgerycalculatorineyeswithpriorradialkeratotomy |