Cargando…

Comparative Evaluation of Canal Transportation and Centering Ratio in Curved Canals: A Study of Cone-beam Computed Tomography and Micro-computed Tomography

INTRODUCTION: This study aimed to compare the accuracy and agreement between cone-beam computed tomography (CBCT) and micro-computed tomography (micro-CT) in the assessment of canal transportation and centering ratio following root canal instrumentation with rotary files. MATERIAL AND METHODS: Twent...

Descripción completa

Detalles Bibliográficos
Autores principales: Shantiaee, Yazdan, Zandi, Babak, Rahbar Taramsari, Ali, Akbarzadeh Baghban, Alireza, Zargar, Nazanin, Shojaeian, Shiva, Mortezapour, Niloofar, Shantiaee, Kourosh, Soltaninejad, Fatemeh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Iranian Center for Endodontic Research 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10566004/
https://www.ncbi.nlm.nih.gov/pubmed/37829838
http://dx.doi.org/10.22037/iej.v18i4.41541
_version_ 1785118824182317056
author Shantiaee, Yazdan
Zandi, Babak
Rahbar Taramsari, Ali
Akbarzadeh Baghban, Alireza
Zargar, Nazanin
Shojaeian, Shiva
Mortezapour, Niloofar
Shantiaee, Kourosh
Soltaninejad, Fatemeh
author_facet Shantiaee, Yazdan
Zandi, Babak
Rahbar Taramsari, Ali
Akbarzadeh Baghban, Alireza
Zargar, Nazanin
Shojaeian, Shiva
Mortezapour, Niloofar
Shantiaee, Kourosh
Soltaninejad, Fatemeh
author_sort Shantiaee, Yazdan
collection PubMed
description INTRODUCTION: This study aimed to compare the accuracy and agreement between cone-beam computed tomography (CBCT) and micro-computed tomography (micro-CT) in the assessment of canal transportation and centering ratio following root canal instrumentation with rotary files. MATERIAL AND METHODS: Twenty mesiobuccal canals of mandibular molars were prepared using the 2Shape sequential rotary system. CBCT and micro-CT scans were performed before and after instrumentation, and the magnitude of transportation and centering ratio were measured. The acceptable transportation was set at ≤0.15 mm. The accuracy and agreement between CBCT and micro-CT were calculated, and the intra-class correlation coefficient (ICC) and kappa coefficient were determined to assess the agreement between the two modalities. Statistical analyses were performed using repeated measures ANOVA. RESULTS: Transportation was detected by both modalities at all distances from the apex after instrumentation. The agreement between CBCT and micro-CT in assessing canal transportation was observed in 80%, 85%, 75%, and 75% of specimens at 1-, 3-, 5-, and 7-mm from the apex, respectively. The ICC for transportation and centering ratio was much lower than 0.75, indicating poor agreement between the modalities. The kappa coefficient did not show acceptable agreement between the methods. CONCLUSIONS: CBCT and micro-CT demonstrated poor agreement in assessing canal transportation and centering ratio. Micro-CT remains the preferred modality for in vitro investigations, while CBCT should be limited to clinical settings.
format Online
Article
Text
id pubmed-10566004
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Iranian Center for Endodontic Research
record_format MEDLINE/PubMed
spelling pubmed-105660042023-10-12 Comparative Evaluation of Canal Transportation and Centering Ratio in Curved Canals: A Study of Cone-beam Computed Tomography and Micro-computed Tomography Shantiaee, Yazdan Zandi, Babak Rahbar Taramsari, Ali Akbarzadeh Baghban, Alireza Zargar, Nazanin Shojaeian, Shiva Mortezapour, Niloofar Shantiaee, Kourosh Soltaninejad, Fatemeh Iran Endod J Original Article INTRODUCTION: This study aimed to compare the accuracy and agreement between cone-beam computed tomography (CBCT) and micro-computed tomography (micro-CT) in the assessment of canal transportation and centering ratio following root canal instrumentation with rotary files. MATERIAL AND METHODS: Twenty mesiobuccal canals of mandibular molars were prepared using the 2Shape sequential rotary system. CBCT and micro-CT scans were performed before and after instrumentation, and the magnitude of transportation and centering ratio were measured. The acceptable transportation was set at ≤0.15 mm. The accuracy and agreement between CBCT and micro-CT were calculated, and the intra-class correlation coefficient (ICC) and kappa coefficient were determined to assess the agreement between the two modalities. Statistical analyses were performed using repeated measures ANOVA. RESULTS: Transportation was detected by both modalities at all distances from the apex after instrumentation. The agreement between CBCT and micro-CT in assessing canal transportation was observed in 80%, 85%, 75%, and 75% of specimens at 1-, 3-, 5-, and 7-mm from the apex, respectively. The ICC for transportation and centering ratio was much lower than 0.75, indicating poor agreement between the modalities. The kappa coefficient did not show acceptable agreement between the methods. CONCLUSIONS: CBCT and micro-CT demonstrated poor agreement in assessing canal transportation and centering ratio. Micro-CT remains the preferred modality for in vitro investigations, while CBCT should be limited to clinical settings. Iranian Center for Endodontic Research 2023 /pmc/articles/PMC10566004/ /pubmed/37829838 http://dx.doi.org/10.22037/iej.v18i4.41541 Text en https://creativecommons.org/licenses/by-nc-sa/4.0/This open-access article has been distributed under the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0 https://creativecommons.org/licenses/by-nc-sa/4.0/).
spellingShingle Original Article
Shantiaee, Yazdan
Zandi, Babak
Rahbar Taramsari, Ali
Akbarzadeh Baghban, Alireza
Zargar, Nazanin
Shojaeian, Shiva
Mortezapour, Niloofar
Shantiaee, Kourosh
Soltaninejad, Fatemeh
Comparative Evaluation of Canal Transportation and Centering Ratio in Curved Canals: A Study of Cone-beam Computed Tomography and Micro-computed Tomography
title Comparative Evaluation of Canal Transportation and Centering Ratio in Curved Canals: A Study of Cone-beam Computed Tomography and Micro-computed Tomography
title_full Comparative Evaluation of Canal Transportation and Centering Ratio in Curved Canals: A Study of Cone-beam Computed Tomography and Micro-computed Tomography
title_fullStr Comparative Evaluation of Canal Transportation and Centering Ratio in Curved Canals: A Study of Cone-beam Computed Tomography and Micro-computed Tomography
title_full_unstemmed Comparative Evaluation of Canal Transportation and Centering Ratio in Curved Canals: A Study of Cone-beam Computed Tomography and Micro-computed Tomography
title_short Comparative Evaluation of Canal Transportation and Centering Ratio in Curved Canals: A Study of Cone-beam Computed Tomography and Micro-computed Tomography
title_sort comparative evaluation of canal transportation and centering ratio in curved canals: a study of cone-beam computed tomography and micro-computed tomography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10566004/
https://www.ncbi.nlm.nih.gov/pubmed/37829838
http://dx.doi.org/10.22037/iej.v18i4.41541
work_keys_str_mv AT shantiaeeyazdan comparativeevaluationofcanaltransportationandcenteringratioincurvedcanalsastudyofconebeamcomputedtomographyandmicrocomputedtomography
AT zandibabak comparativeevaluationofcanaltransportationandcenteringratioincurvedcanalsastudyofconebeamcomputedtomographyandmicrocomputedtomography
AT rahbartaramsariali comparativeevaluationofcanaltransportationandcenteringratioincurvedcanalsastudyofconebeamcomputedtomographyandmicrocomputedtomography
AT akbarzadehbaghbanalireza comparativeevaluationofcanaltransportationandcenteringratioincurvedcanalsastudyofconebeamcomputedtomographyandmicrocomputedtomography
AT zargarnazanin comparativeevaluationofcanaltransportationandcenteringratioincurvedcanalsastudyofconebeamcomputedtomographyandmicrocomputedtomography
AT shojaeianshiva comparativeevaluationofcanaltransportationandcenteringratioincurvedcanalsastudyofconebeamcomputedtomographyandmicrocomputedtomography
AT mortezapourniloofar comparativeevaluationofcanaltransportationandcenteringratioincurvedcanalsastudyofconebeamcomputedtomographyandmicrocomputedtomography
AT shantiaeekourosh comparativeevaluationofcanaltransportationandcenteringratioincurvedcanalsastudyofconebeamcomputedtomographyandmicrocomputedtomography
AT soltaninejadfatemeh comparativeevaluationofcanaltransportationandcenteringratioincurvedcanalsastudyofconebeamcomputedtomographyandmicrocomputedtomography