Cargando…
Comparative Evaluation of Canal Transportation and Centering Ratio in Curved Canals: A Study of Cone-beam Computed Tomography and Micro-computed Tomography
INTRODUCTION: This study aimed to compare the accuracy and agreement between cone-beam computed tomography (CBCT) and micro-computed tomography (micro-CT) in the assessment of canal transportation and centering ratio following root canal instrumentation with rotary files. MATERIAL AND METHODS: Twent...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Iranian Center for Endodontic Research
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10566004/ https://www.ncbi.nlm.nih.gov/pubmed/37829838 http://dx.doi.org/10.22037/iej.v18i4.41541 |
_version_ | 1785118824182317056 |
---|---|
author | Shantiaee, Yazdan Zandi, Babak Rahbar Taramsari, Ali Akbarzadeh Baghban, Alireza Zargar, Nazanin Shojaeian, Shiva Mortezapour, Niloofar Shantiaee, Kourosh Soltaninejad, Fatemeh |
author_facet | Shantiaee, Yazdan Zandi, Babak Rahbar Taramsari, Ali Akbarzadeh Baghban, Alireza Zargar, Nazanin Shojaeian, Shiva Mortezapour, Niloofar Shantiaee, Kourosh Soltaninejad, Fatemeh |
author_sort | Shantiaee, Yazdan |
collection | PubMed |
description | INTRODUCTION: This study aimed to compare the accuracy and agreement between cone-beam computed tomography (CBCT) and micro-computed tomography (micro-CT) in the assessment of canal transportation and centering ratio following root canal instrumentation with rotary files. MATERIAL AND METHODS: Twenty mesiobuccal canals of mandibular molars were prepared using the 2Shape sequential rotary system. CBCT and micro-CT scans were performed before and after instrumentation, and the magnitude of transportation and centering ratio were measured. The acceptable transportation was set at ≤0.15 mm. The accuracy and agreement between CBCT and micro-CT were calculated, and the intra-class correlation coefficient (ICC) and kappa coefficient were determined to assess the agreement between the two modalities. Statistical analyses were performed using repeated measures ANOVA. RESULTS: Transportation was detected by both modalities at all distances from the apex after instrumentation. The agreement between CBCT and micro-CT in assessing canal transportation was observed in 80%, 85%, 75%, and 75% of specimens at 1-, 3-, 5-, and 7-mm from the apex, respectively. The ICC for transportation and centering ratio was much lower than 0.75, indicating poor agreement between the modalities. The kappa coefficient did not show acceptable agreement between the methods. CONCLUSIONS: CBCT and micro-CT demonstrated poor agreement in assessing canal transportation and centering ratio. Micro-CT remains the preferred modality for in vitro investigations, while CBCT should be limited to clinical settings. |
format | Online Article Text |
id | pubmed-10566004 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Iranian Center for Endodontic Research |
record_format | MEDLINE/PubMed |
spelling | pubmed-105660042023-10-12 Comparative Evaluation of Canal Transportation and Centering Ratio in Curved Canals: A Study of Cone-beam Computed Tomography and Micro-computed Tomography Shantiaee, Yazdan Zandi, Babak Rahbar Taramsari, Ali Akbarzadeh Baghban, Alireza Zargar, Nazanin Shojaeian, Shiva Mortezapour, Niloofar Shantiaee, Kourosh Soltaninejad, Fatemeh Iran Endod J Original Article INTRODUCTION: This study aimed to compare the accuracy and agreement between cone-beam computed tomography (CBCT) and micro-computed tomography (micro-CT) in the assessment of canal transportation and centering ratio following root canal instrumentation with rotary files. MATERIAL AND METHODS: Twenty mesiobuccal canals of mandibular molars were prepared using the 2Shape sequential rotary system. CBCT and micro-CT scans were performed before and after instrumentation, and the magnitude of transportation and centering ratio were measured. The acceptable transportation was set at ≤0.15 mm. The accuracy and agreement between CBCT and micro-CT were calculated, and the intra-class correlation coefficient (ICC) and kappa coefficient were determined to assess the agreement between the two modalities. Statistical analyses were performed using repeated measures ANOVA. RESULTS: Transportation was detected by both modalities at all distances from the apex after instrumentation. The agreement between CBCT and micro-CT in assessing canal transportation was observed in 80%, 85%, 75%, and 75% of specimens at 1-, 3-, 5-, and 7-mm from the apex, respectively. The ICC for transportation and centering ratio was much lower than 0.75, indicating poor agreement between the modalities. The kappa coefficient did not show acceptable agreement between the methods. CONCLUSIONS: CBCT and micro-CT demonstrated poor agreement in assessing canal transportation and centering ratio. Micro-CT remains the preferred modality for in vitro investigations, while CBCT should be limited to clinical settings. Iranian Center for Endodontic Research 2023 /pmc/articles/PMC10566004/ /pubmed/37829838 http://dx.doi.org/10.22037/iej.v18i4.41541 Text en https://creativecommons.org/licenses/by-nc-sa/4.0/This open-access article has been distributed under the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0 https://creativecommons.org/licenses/by-nc-sa/4.0/). |
spellingShingle | Original Article Shantiaee, Yazdan Zandi, Babak Rahbar Taramsari, Ali Akbarzadeh Baghban, Alireza Zargar, Nazanin Shojaeian, Shiva Mortezapour, Niloofar Shantiaee, Kourosh Soltaninejad, Fatemeh Comparative Evaluation of Canal Transportation and Centering Ratio in Curved Canals: A Study of Cone-beam Computed Tomography and Micro-computed Tomography |
title | Comparative Evaluation of Canal Transportation and Centering Ratio in Curved Canals: A Study of Cone-beam Computed Tomography and Micro-computed Tomography |
title_full | Comparative Evaluation of Canal Transportation and Centering Ratio in Curved Canals: A Study of Cone-beam Computed Tomography and Micro-computed Tomography |
title_fullStr | Comparative Evaluation of Canal Transportation and Centering Ratio in Curved Canals: A Study of Cone-beam Computed Tomography and Micro-computed Tomography |
title_full_unstemmed | Comparative Evaluation of Canal Transportation and Centering Ratio in Curved Canals: A Study of Cone-beam Computed Tomography and Micro-computed Tomography |
title_short | Comparative Evaluation of Canal Transportation and Centering Ratio in Curved Canals: A Study of Cone-beam Computed Tomography and Micro-computed Tomography |
title_sort | comparative evaluation of canal transportation and centering ratio in curved canals: a study of cone-beam computed tomography and micro-computed tomography |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10566004/ https://www.ncbi.nlm.nih.gov/pubmed/37829838 http://dx.doi.org/10.22037/iej.v18i4.41541 |
work_keys_str_mv | AT shantiaeeyazdan comparativeevaluationofcanaltransportationandcenteringratioincurvedcanalsastudyofconebeamcomputedtomographyandmicrocomputedtomography AT zandibabak comparativeevaluationofcanaltransportationandcenteringratioincurvedcanalsastudyofconebeamcomputedtomographyandmicrocomputedtomography AT rahbartaramsariali comparativeevaluationofcanaltransportationandcenteringratioincurvedcanalsastudyofconebeamcomputedtomographyandmicrocomputedtomography AT akbarzadehbaghbanalireza comparativeevaluationofcanaltransportationandcenteringratioincurvedcanalsastudyofconebeamcomputedtomographyandmicrocomputedtomography AT zargarnazanin comparativeevaluationofcanaltransportationandcenteringratioincurvedcanalsastudyofconebeamcomputedtomographyandmicrocomputedtomography AT shojaeianshiva comparativeevaluationofcanaltransportationandcenteringratioincurvedcanalsastudyofconebeamcomputedtomographyandmicrocomputedtomography AT mortezapourniloofar comparativeevaluationofcanaltransportationandcenteringratioincurvedcanalsastudyofconebeamcomputedtomographyandmicrocomputedtomography AT shantiaeekourosh comparativeevaluationofcanaltransportationandcenteringratioincurvedcanalsastudyofconebeamcomputedtomographyandmicrocomputedtomography AT soltaninejadfatemeh comparativeevaluationofcanaltransportationandcenteringratioincurvedcanalsastudyofconebeamcomputedtomographyandmicrocomputedtomography |