Cargando…
Susceptibility to Steady Noise Largely Explains Susceptibility to Dynamic Maskers in Cochlear Implant Users, but not in Normal-Hearing Listeners
Different from normal-hearing (NH) listeners, speech recognition thresholds (SRTs) in cochlear implant (CI) users are typically poorer with dynamic maskers than with speech-spectrum noise (SSN). The effectiveness of different masker types may depend on their acoustic and linguistic characteristics....
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10566284/ http://dx.doi.org/10.1177/23312165231205713 |
_version_ | 1785118890994434048 |
---|---|
author | Chen, Biao Shi, Ying Kong, Ying Chen, Jingyuan Zhang, Lifang Li, Yongxin Galvin, John J. Fu, Qian-Jie |
author_facet | Chen, Biao Shi, Ying Kong, Ying Chen, Jingyuan Zhang, Lifang Li, Yongxin Galvin, John J. Fu, Qian-Jie |
author_sort | Chen, Biao |
collection | PubMed |
description | Different from normal-hearing (NH) listeners, speech recognition thresholds (SRTs) in cochlear implant (CI) users are typically poorer with dynamic maskers than with speech-spectrum noise (SSN). The effectiveness of different masker types may depend on their acoustic and linguistic characteristics. The goal of the present study was to evaluate the effectiveness of different masker types with varying acoustic and linguistic properties in CI and NH listeners. SRTs were measured with nine maskers, including SSN, dynamic nonspeech maskers, and speech maskers with or without lexical content. Results showed that CI users performed significantly poorer than NH listeners with all maskers. NH listeners were much more sensitive to masker type than were CI users. Relative to SSN, NH listeners experienced significant masking release for most maskers, which could be well explained by the glimpse proportion, especially for maskers containing similar cues related to fundamental frequency or lexical content. In contrast, CI users generally experienced negative masking release. There was significant intercorrelation among the maskers for CI users’ SRTs but much less so for NH listeners’ SRTs. Principal component analysis showed that one factor explained 72% of the variance in CI users’ SRTs but only 55% in NH listeners’ SRTs across all maskers. Taken together, the results suggest that SRTs in SSN largely accounted for the variability in CI users’ SRTs with dynamic maskers. Different from NH listeners, CI users appear to be more susceptible to energetic masking and do not experience a release from masking with dynamic envelopes or speech maskers. |
format | Online Article Text |
id | pubmed-10566284 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-105662842023-10-12 Susceptibility to Steady Noise Largely Explains Susceptibility to Dynamic Maskers in Cochlear Implant Users, but not in Normal-Hearing Listeners Chen, Biao Shi, Ying Kong, Ying Chen, Jingyuan Zhang, Lifang Li, Yongxin Galvin, John J. Fu, Qian-Jie Trends Hear Original Article Different from normal-hearing (NH) listeners, speech recognition thresholds (SRTs) in cochlear implant (CI) users are typically poorer with dynamic maskers than with speech-spectrum noise (SSN). The effectiveness of different masker types may depend on their acoustic and linguistic characteristics. The goal of the present study was to evaluate the effectiveness of different masker types with varying acoustic and linguistic properties in CI and NH listeners. SRTs were measured with nine maskers, including SSN, dynamic nonspeech maskers, and speech maskers with or without lexical content. Results showed that CI users performed significantly poorer than NH listeners with all maskers. NH listeners were much more sensitive to masker type than were CI users. Relative to SSN, NH listeners experienced significant masking release for most maskers, which could be well explained by the glimpse proportion, especially for maskers containing similar cues related to fundamental frequency or lexical content. In contrast, CI users generally experienced negative masking release. There was significant intercorrelation among the maskers for CI users’ SRTs but much less so for NH listeners’ SRTs. Principal component analysis showed that one factor explained 72% of the variance in CI users’ SRTs but only 55% in NH listeners’ SRTs across all maskers. Taken together, the results suggest that SRTs in SSN largely accounted for the variability in CI users’ SRTs with dynamic maskers. Different from NH listeners, CI users appear to be more susceptible to energetic masking and do not experience a release from masking with dynamic envelopes or speech maskers. SAGE Publications 2023-10-11 /pmc/articles/PMC10566284/ http://dx.doi.org/10.1177/23312165231205713 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Article Chen, Biao Shi, Ying Kong, Ying Chen, Jingyuan Zhang, Lifang Li, Yongxin Galvin, John J. Fu, Qian-Jie Susceptibility to Steady Noise Largely Explains Susceptibility to Dynamic Maskers in Cochlear Implant Users, but not in Normal-Hearing Listeners |
title | Susceptibility to Steady Noise Largely Explains Susceptibility to Dynamic Maskers in Cochlear Implant Users, but not in Normal-Hearing Listeners |
title_full | Susceptibility to Steady Noise Largely Explains Susceptibility to Dynamic Maskers in Cochlear Implant Users, but not in Normal-Hearing Listeners |
title_fullStr | Susceptibility to Steady Noise Largely Explains Susceptibility to Dynamic Maskers in Cochlear Implant Users, but not in Normal-Hearing Listeners |
title_full_unstemmed | Susceptibility to Steady Noise Largely Explains Susceptibility to Dynamic Maskers in Cochlear Implant Users, but not in Normal-Hearing Listeners |
title_short | Susceptibility to Steady Noise Largely Explains Susceptibility to Dynamic Maskers in Cochlear Implant Users, but not in Normal-Hearing Listeners |
title_sort | susceptibility to steady noise largely explains susceptibility to dynamic maskers in cochlear implant users, but not in normal-hearing listeners |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10566284/ http://dx.doi.org/10.1177/23312165231205713 |
work_keys_str_mv | AT chenbiao susceptibilitytosteadynoiselargelyexplainssusceptibilitytodynamicmaskersincochlearimplantusersbutnotinnormalhearinglisteners AT shiying susceptibilitytosteadynoiselargelyexplainssusceptibilitytodynamicmaskersincochlearimplantusersbutnotinnormalhearinglisteners AT kongying susceptibilitytosteadynoiselargelyexplainssusceptibilitytodynamicmaskersincochlearimplantusersbutnotinnormalhearinglisteners AT chenjingyuan susceptibilitytosteadynoiselargelyexplainssusceptibilitytodynamicmaskersincochlearimplantusersbutnotinnormalhearinglisteners AT zhanglifang susceptibilitytosteadynoiselargelyexplainssusceptibilitytodynamicmaskersincochlearimplantusersbutnotinnormalhearinglisteners AT liyongxin susceptibilitytosteadynoiselargelyexplainssusceptibilitytodynamicmaskersincochlearimplantusersbutnotinnormalhearinglisteners AT galvinjohnj susceptibilitytosteadynoiselargelyexplainssusceptibilitytodynamicmaskersincochlearimplantusersbutnotinnormalhearinglisteners AT fuqianjie susceptibilitytosteadynoiselargelyexplainssusceptibilitytodynamicmaskersincochlearimplantusersbutnotinnormalhearinglisteners |