Cargando…

Lower Extremity Orthopedic Augmentation Utilizing a Synthetic Hybrid-Scale Fiber Matrix

Introduction Lower extremity injuries represent about 15% of all emergency room visits in the United States, with ankle injuries accounting for 20% of these. Surgical site infections resulting from ankle reconstructive surgery can result in severe complications, including amputation. Depending on th...

Descripción completa

Detalles Bibliográficos
Autor principal: Rushing, Calvin J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10566574/
https://www.ncbi.nlm.nih.gov/pubmed/37829993
http://dx.doi.org/10.7759/cureus.45046
_version_ 1785118939759509504
author Rushing, Calvin J
author_facet Rushing, Calvin J
author_sort Rushing, Calvin J
collection PubMed
description Introduction Lower extremity injuries represent about 15% of all emergency room visits in the United States, with ankle injuries accounting for 20% of these. Surgical site infections resulting from ankle reconstructive surgery can result in severe complications, including amputation. Depending on the procedure performed, surgical site infections of ankle reconstructive surgery can occur at a rate as high as 14%. A synthetic hybrid-scale fiber matrix with an engineered design resembling a native human extracellular matrix could be utilized to augment these difficult surgical procedures. Materials and methods A retrospective review of 10 patients who underwent orthopedic reconstructive surgeries of lower extremity injuries that were augmented with the synthetic hybrid-scale fiber matrix between October 2021 and February 2022 was conducted. Results Injuries included Achilles ruptures, bimalleolar and trimalleolar ankle fractures, ankle arthrodesis, and injuries of various other etiologies. All surgical wounds achieved complete closure and patients went on to fully recover. The average time to wound closure was 12.6 days after an average of 1.2 applications of the synthetic hybrid-scale fiber matrix. Post-reconstruction, two patients went on to have complications unrelated to the synthetic hybrid-scale fiber matrix, which then went on to heal uneventfully. Conclusions The positive results seen with the retrospective case series indicated that the synthetic hybrid-scale fiber matrix can promote healing and should be considered as an option in at-risk lower extremity reconstructive procedures.
format Online
Article
Text
id pubmed-10566574
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-105665742023-10-12 Lower Extremity Orthopedic Augmentation Utilizing a Synthetic Hybrid-Scale Fiber Matrix Rushing, Calvin J Cureus Other Introduction Lower extremity injuries represent about 15% of all emergency room visits in the United States, with ankle injuries accounting for 20% of these. Surgical site infections resulting from ankle reconstructive surgery can result in severe complications, including amputation. Depending on the procedure performed, surgical site infections of ankle reconstructive surgery can occur at a rate as high as 14%. A synthetic hybrid-scale fiber matrix with an engineered design resembling a native human extracellular matrix could be utilized to augment these difficult surgical procedures. Materials and methods A retrospective review of 10 patients who underwent orthopedic reconstructive surgeries of lower extremity injuries that were augmented with the synthetic hybrid-scale fiber matrix between October 2021 and February 2022 was conducted. Results Injuries included Achilles ruptures, bimalleolar and trimalleolar ankle fractures, ankle arthrodesis, and injuries of various other etiologies. All surgical wounds achieved complete closure and patients went on to fully recover. The average time to wound closure was 12.6 days after an average of 1.2 applications of the synthetic hybrid-scale fiber matrix. Post-reconstruction, two patients went on to have complications unrelated to the synthetic hybrid-scale fiber matrix, which then went on to heal uneventfully. Conclusions The positive results seen with the retrospective case series indicated that the synthetic hybrid-scale fiber matrix can promote healing and should be considered as an option in at-risk lower extremity reconstructive procedures. Cureus 2023-09-11 /pmc/articles/PMC10566574/ /pubmed/37829993 http://dx.doi.org/10.7759/cureus.45046 Text en Copyright © 2023, Rushing et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Other
Rushing, Calvin J
Lower Extremity Orthopedic Augmentation Utilizing a Synthetic Hybrid-Scale Fiber Matrix
title Lower Extremity Orthopedic Augmentation Utilizing a Synthetic Hybrid-Scale Fiber Matrix
title_full Lower Extremity Orthopedic Augmentation Utilizing a Synthetic Hybrid-Scale Fiber Matrix
title_fullStr Lower Extremity Orthopedic Augmentation Utilizing a Synthetic Hybrid-Scale Fiber Matrix
title_full_unstemmed Lower Extremity Orthopedic Augmentation Utilizing a Synthetic Hybrid-Scale Fiber Matrix
title_short Lower Extremity Orthopedic Augmentation Utilizing a Synthetic Hybrid-Scale Fiber Matrix
title_sort lower extremity orthopedic augmentation utilizing a synthetic hybrid-scale fiber matrix
topic Other
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10566574/
https://www.ncbi.nlm.nih.gov/pubmed/37829993
http://dx.doi.org/10.7759/cureus.45046
work_keys_str_mv AT rushingcalvinj lowerextremityorthopedicaugmentationutilizingasynthetichybridscalefibermatrix