Comparative studies of the sensitivities of sparse and full geometries of Total-Body PET scanners built from crystals and plastic scintillators
BACKGROUND: Alongside the benefits of Total-Body imaging modalities, such as higher sensitivity, single-bed position, low dose imaging, etc., their final construction cost prevents worldwide utilization. The main aim of this study is to present a simulation-based comparison of the sensitivities of e...
Autores principales: | , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10567620/ https://www.ncbi.nlm.nih.gov/pubmed/37819578 http://dx.doi.org/10.1186/s40658-023-00572-5 |
_version_ | 1785119168519995392 |
---|---|
author | Dadgar, M. Parzych, S. Baran, J. Chug, N. Curceanu, C. Czerwiński, E. Dulski, K. Elyan, K. Gajos, A. Hiesmayr, B. C. Kapłon, Ł. Klimaszewski, K. Konieczka, P. Korcyl, G. Kozik, T. Krzemien, W. Kumar, D. Niedzwiecki, S. Panek, D. Perez del Rio, E. Raczyński, L. Sharma, S. Shivani, S. Shopa, R. Y. Skurzok, M. Stepień, E. Ł. Tayefi Ardebili, F. Tayefi Ardebili, K. Vandenberghe, S. Wiślicki, W. Moskal, P. |
author_facet | Dadgar, M. Parzych, S. Baran, J. Chug, N. Curceanu, C. Czerwiński, E. Dulski, K. Elyan, K. Gajos, A. Hiesmayr, B. C. Kapłon, Ł. Klimaszewski, K. Konieczka, P. Korcyl, G. Kozik, T. Krzemien, W. Kumar, D. Niedzwiecki, S. Panek, D. Perez del Rio, E. Raczyński, L. Sharma, S. Shivani, S. Shopa, R. Y. Skurzok, M. Stepień, E. Ł. Tayefi Ardebili, F. Tayefi Ardebili, K. Vandenberghe, S. Wiślicki, W. Moskal, P. |
author_sort | Dadgar, M. |
collection | PubMed |
description | BACKGROUND: Alongside the benefits of Total-Body imaging modalities, such as higher sensitivity, single-bed position, low dose imaging, etc., their final construction cost prevents worldwide utilization. The main aim of this study is to present a simulation-based comparison of the sensitivities of existing and currently developed tomographs to introduce a cost-efficient solution for constructing a Total-Body PET scanner based on plastic scintillators. METHODS: For the case of this study, eight tomographs based on the uEXPLORER configuration with different scintillator materials (BGO, LYSO), axial field-of-view (97.4 cm and 194.8 cm), and detector configurations (full and sparse) were simulated. In addition, 8 J-PET scanners with different configurations, such as various axial field-of-view (200 cm and 250 cm), different cross sections of plastic scintillator, and multiple numbers of plastic scintillator layers (2, 3, and 4), based on J-PET technology have been simulated by GATE software. Furthermore, Siemens’ Biograph Vision has been simulated to compare the results with standard PET scans. Two types of simulations have been performed. The first one with a centrally located source with a diameter of 1 mm and a length of 250 cm, and the second one with the same source inside a water-filled cylindrical phantom with a diameter of 20 cm and a length of 183 cm. RESULTS: With regards to sensitivity, among all the proposed scanners, the ones constructed with BGO crystals give the best performance ([Formula: see text] 350 cps/kBq at the center). The utilization of sparse geometry or LYSO crystals significantly lowers the achievable sensitivity of such systems. The J-PET design gives a similar sensitivity to the sparse LYSO crystal-based detectors while having full detector coverage over the body. Moreover, it provides uniform sensitivity over the body with additional gain on its sides and provides the possibility for high-quality brain imaging. CONCLUSION: Taking into account not only the sensitivity but also the price of Total-Body PET tomographs, which till now was one of the main obstacles in their widespread clinical availability, the J-PET tomography system based on plastic scintillators could be a cost-efficient alternative for Total-Body PET scanners. |
format | Online Article Text |
id | pubmed-10567620 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-105676202023-10-13 Comparative studies of the sensitivities of sparse and full geometries of Total-Body PET scanners built from crystals and plastic scintillators Dadgar, M. Parzych, S. Baran, J. Chug, N. Curceanu, C. Czerwiński, E. Dulski, K. Elyan, K. Gajos, A. Hiesmayr, B. C. Kapłon, Ł. Klimaszewski, K. Konieczka, P. Korcyl, G. Kozik, T. Krzemien, W. Kumar, D. Niedzwiecki, S. Panek, D. Perez del Rio, E. Raczyński, L. Sharma, S. Shivani, S. Shopa, R. Y. Skurzok, M. Stepień, E. Ł. Tayefi Ardebili, F. Tayefi Ardebili, K. Vandenberghe, S. Wiślicki, W. Moskal, P. EJNMMI Phys Original Research BACKGROUND: Alongside the benefits of Total-Body imaging modalities, such as higher sensitivity, single-bed position, low dose imaging, etc., their final construction cost prevents worldwide utilization. The main aim of this study is to present a simulation-based comparison of the sensitivities of existing and currently developed tomographs to introduce a cost-efficient solution for constructing a Total-Body PET scanner based on plastic scintillators. METHODS: For the case of this study, eight tomographs based on the uEXPLORER configuration with different scintillator materials (BGO, LYSO), axial field-of-view (97.4 cm and 194.8 cm), and detector configurations (full and sparse) were simulated. In addition, 8 J-PET scanners with different configurations, such as various axial field-of-view (200 cm and 250 cm), different cross sections of plastic scintillator, and multiple numbers of plastic scintillator layers (2, 3, and 4), based on J-PET technology have been simulated by GATE software. Furthermore, Siemens’ Biograph Vision has been simulated to compare the results with standard PET scans. Two types of simulations have been performed. The first one with a centrally located source with a diameter of 1 mm and a length of 250 cm, and the second one with the same source inside a water-filled cylindrical phantom with a diameter of 20 cm and a length of 183 cm. RESULTS: With regards to sensitivity, among all the proposed scanners, the ones constructed with BGO crystals give the best performance ([Formula: see text] 350 cps/kBq at the center). The utilization of sparse geometry or LYSO crystals significantly lowers the achievable sensitivity of such systems. The J-PET design gives a similar sensitivity to the sparse LYSO crystal-based detectors while having full detector coverage over the body. Moreover, it provides uniform sensitivity over the body with additional gain on its sides and provides the possibility for high-quality brain imaging. CONCLUSION: Taking into account not only the sensitivity but also the price of Total-Body PET tomographs, which till now was one of the main obstacles in their widespread clinical availability, the J-PET tomography system based on plastic scintillators could be a cost-efficient alternative for Total-Body PET scanners. Springer International Publishing 2023-10-11 /pmc/articles/PMC10567620/ /pubmed/37819578 http://dx.doi.org/10.1186/s40658-023-00572-5 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Research Dadgar, M. Parzych, S. Baran, J. Chug, N. Curceanu, C. Czerwiński, E. Dulski, K. Elyan, K. Gajos, A. Hiesmayr, B. C. Kapłon, Ł. Klimaszewski, K. Konieczka, P. Korcyl, G. Kozik, T. Krzemien, W. Kumar, D. Niedzwiecki, S. Panek, D. Perez del Rio, E. Raczyński, L. Sharma, S. Shivani, S. Shopa, R. Y. Skurzok, M. Stepień, E. Ł. Tayefi Ardebili, F. Tayefi Ardebili, K. Vandenberghe, S. Wiślicki, W. Moskal, P. Comparative studies of the sensitivities of sparse and full geometries of Total-Body PET scanners built from crystals and plastic scintillators |
title | Comparative studies of the sensitivities of sparse and full geometries of Total-Body PET scanners built from crystals and plastic scintillators |
title_full | Comparative studies of the sensitivities of sparse and full geometries of Total-Body PET scanners built from crystals and plastic scintillators |
title_fullStr | Comparative studies of the sensitivities of sparse and full geometries of Total-Body PET scanners built from crystals and plastic scintillators |
title_full_unstemmed | Comparative studies of the sensitivities of sparse and full geometries of Total-Body PET scanners built from crystals and plastic scintillators |
title_short | Comparative studies of the sensitivities of sparse and full geometries of Total-Body PET scanners built from crystals and plastic scintillators |
title_sort | comparative studies of the sensitivities of sparse and full geometries of total-body pet scanners built from crystals and plastic scintillators |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10567620/ https://www.ncbi.nlm.nih.gov/pubmed/37819578 http://dx.doi.org/10.1186/s40658-023-00572-5 |
work_keys_str_mv | AT dadgarm comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT parzychs comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT baranj comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT chugn comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT curceanuc comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT czerwinskie comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT dulskik comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT elyank comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT gajosa comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT hiesmayrbc comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT kapłonł comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT klimaszewskik comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT konieczkap comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT korcylg comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT kozikt comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT krzemienw comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT kumard comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT niedzwieckis comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT panekd comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT perezdelrioe comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT raczynskil comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT sharmas comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT shivanis comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT shopary comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT skurzokm comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT stepieneł comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT tayefiardebilif comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT tayefiardebilik comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT vandenberghes comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT wislickiw comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators AT moskalp comparativestudiesofthesensitivitiesofsparseandfullgeometriesoftotalbodypetscannersbuiltfromcrystalsandplasticscintillators |