Cargando…

Application of atmospheric pressure field desorption for the analysis of anionic surfactants in commercial detergents

Recent work has shown that field desorption (FD) and field ionization (FI) using activated field emitters may be performed at atmospheric pressure, too. While some limitations apply to atmospheric pressure field desorption (APFD) mass spectrometry (MS), the method can deliver both positive and negat...

Descripción completa

Detalles Bibliográficos
Autor principal: Gross, Jürgen H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10567867/
https://www.ncbi.nlm.nih.gov/pubmed/37644322
http://dx.doi.org/10.1007/s00216-023-04917-y
_version_ 1785119231233228800
author Gross, Jürgen H.
author_facet Gross, Jürgen H.
author_sort Gross, Jürgen H.
collection PubMed
description Recent work has shown that field desorption (FD) and field ionization (FI) using activated field emitters may be performed at atmospheric pressure, too. While some limitations apply to atmospheric pressure field desorption (APFD) mass spectrometry (MS), the method can deliver both positive and negative even electron ions of highly polar or ionic compounds. Furthermore, APFD even permits the generation of positive molecular ions of polycyclic aromatic compounds. Here, an application of negative-ion APFD for the analysis of anionic surfactants contained in commercial detergent products for body care, household, and technical uses is presented. The samples include liquid soaps and shower gels, dishwashing liquids, and cooling lubricants. Surfactant solutions in methanol/water or pure methanol at 2–10 µl ml(−1) were deposited on commercial 13-µm activated tungsten emitters. The emitters were positioned in front of the atmospheric pressure interface of a Fourier transform-ion cyclotron resonance (FT-ICR) mass spectrometer by means of a slightly modified nano-electrospray ionization (nanoESI) source. The entrance electrode of the interface was set to positive high voltage with respect to the emitter at ground potential. Under these conditions, negative-ion desorption was achieved. The surfactant anions, organic sulfates and organic sulfonates, were characterized by accurate mass-based formula assignments, and in part, by tandem mass spectrometry. The negative-ion APFD spectra were compared to results by negative-ion electrospray ionization (ESI) either obtained using the FT-ICR mass spectrometer or by using a trapped ion mobility-quadrupole-time-of-flight (TIMS-Q-TOF) instrument when product ions of low m/z needed to be detected in tandem MS. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00216-023-04917-y.
format Online
Article
Text
id pubmed-10567867
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-105678672023-10-13 Application of atmospheric pressure field desorption for the analysis of anionic surfactants in commercial detergents Gross, Jürgen H. Anal Bioanal Chem Research Paper Recent work has shown that field desorption (FD) and field ionization (FI) using activated field emitters may be performed at atmospheric pressure, too. While some limitations apply to atmospheric pressure field desorption (APFD) mass spectrometry (MS), the method can deliver both positive and negative even electron ions of highly polar or ionic compounds. Furthermore, APFD even permits the generation of positive molecular ions of polycyclic aromatic compounds. Here, an application of negative-ion APFD for the analysis of anionic surfactants contained in commercial detergent products for body care, household, and technical uses is presented. The samples include liquid soaps and shower gels, dishwashing liquids, and cooling lubricants. Surfactant solutions in methanol/water or pure methanol at 2–10 µl ml(−1) were deposited on commercial 13-µm activated tungsten emitters. The emitters were positioned in front of the atmospheric pressure interface of a Fourier transform-ion cyclotron resonance (FT-ICR) mass spectrometer by means of a slightly modified nano-electrospray ionization (nanoESI) source. The entrance electrode of the interface was set to positive high voltage with respect to the emitter at ground potential. Under these conditions, negative-ion desorption was achieved. The surfactant anions, organic sulfates and organic sulfonates, were characterized by accurate mass-based formula assignments, and in part, by tandem mass spectrometry. The negative-ion APFD spectra were compared to results by negative-ion electrospray ionization (ESI) either obtained using the FT-ICR mass spectrometer or by using a trapped ion mobility-quadrupole-time-of-flight (TIMS-Q-TOF) instrument when product ions of low m/z needed to be detected in tandem MS. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00216-023-04917-y. Springer Berlin Heidelberg 2023-08-30 2023 /pmc/articles/PMC10567867/ /pubmed/37644322 http://dx.doi.org/10.1007/s00216-023-04917-y Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research Paper
Gross, Jürgen H.
Application of atmospheric pressure field desorption for the analysis of anionic surfactants in commercial detergents
title Application of atmospheric pressure field desorption for the analysis of anionic surfactants in commercial detergents
title_full Application of atmospheric pressure field desorption for the analysis of anionic surfactants in commercial detergents
title_fullStr Application of atmospheric pressure field desorption for the analysis of anionic surfactants in commercial detergents
title_full_unstemmed Application of atmospheric pressure field desorption for the analysis of anionic surfactants in commercial detergents
title_short Application of atmospheric pressure field desorption for the analysis of anionic surfactants in commercial detergents
title_sort application of atmospheric pressure field desorption for the analysis of anionic surfactants in commercial detergents
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10567867/
https://www.ncbi.nlm.nih.gov/pubmed/37644322
http://dx.doi.org/10.1007/s00216-023-04917-y
work_keys_str_mv AT grossjurgenh applicationofatmosphericpressurefielddesorptionfortheanalysisofanionicsurfactantsincommercialdetergents