Cargando…
Electromagnetic force investigation of electromagnets with variable pole area in an electromagnetic diaphragm pump
Electromagnetic diaphragm pump is a kind of widely applied diaphragm pump that has promising sealing performance, simple structure and low power loss. Planar pole electromagnet is a significant component of the electromagnetic diaphragm pump. However, the sharply changing displacement-force characte...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10569539/ https://www.ncbi.nlm.nih.gov/pubmed/37824558 http://dx.doi.org/10.1371/journal.pone.0292685 |
_version_ | 1785119567256748032 |
---|---|
author | Liao, Yu Liu, Yinshui Xing, Jun Chen, Biao Gao, Lizhi |
author_facet | Liao, Yu Liu, Yinshui Xing, Jun Chen, Biao Gao, Lizhi |
author_sort | Liao, Yu |
collection | PubMed |
description | Electromagnetic diaphragm pump is a kind of widely applied diaphragm pump that has promising sealing performance, simple structure and low power loss. Planar pole electromagnet is a significant component of the electromagnetic diaphragm pump. However, the sharply changing displacement-force characteristics of the planar pole electromagnet do not match the constant load characteristics of the electromagnetic diaphragm pump. Herein, an electromagnet with variable pole area is put forward. A theoretical relationship between structural parameters, the Ampere turns and the electromagnetic force of the electromagnet with variable pole area is determined by analyzing the equivalent magnetic circuit of the electromagnet with variable pole area. The experimental results imply that the initial electromagnetic force of the electromagnet with variable pole area is 32.51% larger than the planar pole electromagnet, the engaging electromagnetic force of the electromagnet with variable pole area is 22.3% smaller than the planar pole electromagnet and the displacement-force characteristics of the electromagnet with variable pole area match the constant load characteristics of the electromagnetic diaphragm pump. |
format | Online Article Text |
id | pubmed-10569539 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-105695392023-10-13 Electromagnetic force investigation of electromagnets with variable pole area in an electromagnetic diaphragm pump Liao, Yu Liu, Yinshui Xing, Jun Chen, Biao Gao, Lizhi PLoS One Research Article Electromagnetic diaphragm pump is a kind of widely applied diaphragm pump that has promising sealing performance, simple structure and low power loss. Planar pole electromagnet is a significant component of the electromagnetic diaphragm pump. However, the sharply changing displacement-force characteristics of the planar pole electromagnet do not match the constant load characteristics of the electromagnetic diaphragm pump. Herein, an electromagnet with variable pole area is put forward. A theoretical relationship between structural parameters, the Ampere turns and the electromagnetic force of the electromagnet with variable pole area is determined by analyzing the equivalent magnetic circuit of the electromagnet with variable pole area. The experimental results imply that the initial electromagnetic force of the electromagnet with variable pole area is 32.51% larger than the planar pole electromagnet, the engaging electromagnetic force of the electromagnet with variable pole area is 22.3% smaller than the planar pole electromagnet and the displacement-force characteristics of the electromagnet with variable pole area match the constant load characteristics of the electromagnetic diaphragm pump. Public Library of Science 2023-10-12 /pmc/articles/PMC10569539/ /pubmed/37824558 http://dx.doi.org/10.1371/journal.pone.0292685 Text en © 2023 Liao et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Liao, Yu Liu, Yinshui Xing, Jun Chen, Biao Gao, Lizhi Electromagnetic force investigation of electromagnets with variable pole area in an electromagnetic diaphragm pump |
title | Electromagnetic force investigation of electromagnets with variable pole area in an electromagnetic diaphragm pump |
title_full | Electromagnetic force investigation of electromagnets with variable pole area in an electromagnetic diaphragm pump |
title_fullStr | Electromagnetic force investigation of electromagnets with variable pole area in an electromagnetic diaphragm pump |
title_full_unstemmed | Electromagnetic force investigation of electromagnets with variable pole area in an electromagnetic diaphragm pump |
title_short | Electromagnetic force investigation of electromagnets with variable pole area in an electromagnetic diaphragm pump |
title_sort | electromagnetic force investigation of electromagnets with variable pole area in an electromagnetic diaphragm pump |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10569539/ https://www.ncbi.nlm.nih.gov/pubmed/37824558 http://dx.doi.org/10.1371/journal.pone.0292685 |
work_keys_str_mv | AT liaoyu electromagneticforceinvestigationofelectromagnetswithvariablepoleareainanelectromagneticdiaphragmpump AT liuyinshui electromagneticforceinvestigationofelectromagnetswithvariablepoleareainanelectromagneticdiaphragmpump AT xingjun electromagneticforceinvestigationofelectromagnetswithvariablepoleareainanelectromagneticdiaphragmpump AT chenbiao electromagneticforceinvestigationofelectromagnetswithvariablepoleareainanelectromagneticdiaphragmpump AT gaolizhi electromagneticforceinvestigationofelectromagnetswithvariablepoleareainanelectromagneticdiaphragmpump |