Cargando…

Electromagnetic force investigation of electromagnets with variable pole area in an electromagnetic diaphragm pump

Electromagnetic diaphragm pump is a kind of widely applied diaphragm pump that has promising sealing performance, simple structure and low power loss. Planar pole electromagnet is a significant component of the electromagnetic diaphragm pump. However, the sharply changing displacement-force characte...

Descripción completa

Detalles Bibliográficos
Autores principales: Liao, Yu, Liu, Yinshui, Xing, Jun, Chen, Biao, Gao, Lizhi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10569539/
https://www.ncbi.nlm.nih.gov/pubmed/37824558
http://dx.doi.org/10.1371/journal.pone.0292685
_version_ 1785119567256748032
author Liao, Yu
Liu, Yinshui
Xing, Jun
Chen, Biao
Gao, Lizhi
author_facet Liao, Yu
Liu, Yinshui
Xing, Jun
Chen, Biao
Gao, Lizhi
author_sort Liao, Yu
collection PubMed
description Electromagnetic diaphragm pump is a kind of widely applied diaphragm pump that has promising sealing performance, simple structure and low power loss. Planar pole electromagnet is a significant component of the electromagnetic diaphragm pump. However, the sharply changing displacement-force characteristics of the planar pole electromagnet do not match the constant load characteristics of the electromagnetic diaphragm pump. Herein, an electromagnet with variable pole area is put forward. A theoretical relationship between structural parameters, the Ampere turns and the electromagnetic force of the electromagnet with variable pole area is determined by analyzing the equivalent magnetic circuit of the electromagnet with variable pole area. The experimental results imply that the initial electromagnetic force of the electromagnet with variable pole area is 32.51% larger than the planar pole electromagnet, the engaging electromagnetic force of the electromagnet with variable pole area is 22.3% smaller than the planar pole electromagnet and the displacement-force characteristics of the electromagnet with variable pole area match the constant load characteristics of the electromagnetic diaphragm pump.
format Online
Article
Text
id pubmed-10569539
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-105695392023-10-13 Electromagnetic force investigation of electromagnets with variable pole area in an electromagnetic diaphragm pump Liao, Yu Liu, Yinshui Xing, Jun Chen, Biao Gao, Lizhi PLoS One Research Article Electromagnetic diaphragm pump is a kind of widely applied diaphragm pump that has promising sealing performance, simple structure and low power loss. Planar pole electromagnet is a significant component of the electromagnetic diaphragm pump. However, the sharply changing displacement-force characteristics of the planar pole electromagnet do not match the constant load characteristics of the electromagnetic diaphragm pump. Herein, an electromagnet with variable pole area is put forward. A theoretical relationship between structural parameters, the Ampere turns and the electromagnetic force of the electromagnet with variable pole area is determined by analyzing the equivalent magnetic circuit of the electromagnet with variable pole area. The experimental results imply that the initial electromagnetic force of the electromagnet with variable pole area is 32.51% larger than the planar pole electromagnet, the engaging electromagnetic force of the electromagnet with variable pole area is 22.3% smaller than the planar pole electromagnet and the displacement-force characteristics of the electromagnet with variable pole area match the constant load characteristics of the electromagnetic diaphragm pump. Public Library of Science 2023-10-12 /pmc/articles/PMC10569539/ /pubmed/37824558 http://dx.doi.org/10.1371/journal.pone.0292685 Text en © 2023 Liao et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Liao, Yu
Liu, Yinshui
Xing, Jun
Chen, Biao
Gao, Lizhi
Electromagnetic force investigation of electromagnets with variable pole area in an electromagnetic diaphragm pump
title Electromagnetic force investigation of electromagnets with variable pole area in an electromagnetic diaphragm pump
title_full Electromagnetic force investigation of electromagnets with variable pole area in an electromagnetic diaphragm pump
title_fullStr Electromagnetic force investigation of electromagnets with variable pole area in an electromagnetic diaphragm pump
title_full_unstemmed Electromagnetic force investigation of electromagnets with variable pole area in an electromagnetic diaphragm pump
title_short Electromagnetic force investigation of electromagnets with variable pole area in an electromagnetic diaphragm pump
title_sort electromagnetic force investigation of electromagnets with variable pole area in an electromagnetic diaphragm pump
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10569539/
https://www.ncbi.nlm.nih.gov/pubmed/37824558
http://dx.doi.org/10.1371/journal.pone.0292685
work_keys_str_mv AT liaoyu electromagneticforceinvestigationofelectromagnetswithvariablepoleareainanelectromagneticdiaphragmpump
AT liuyinshui electromagneticforceinvestigationofelectromagnetswithvariablepoleareainanelectromagneticdiaphragmpump
AT xingjun electromagneticforceinvestigationofelectromagnetswithvariablepoleareainanelectromagneticdiaphragmpump
AT chenbiao electromagneticforceinvestigationofelectromagnetswithvariablepoleareainanelectromagneticdiaphragmpump
AT gaolizhi electromagneticforceinvestigationofelectromagnetswithvariablepoleareainanelectromagneticdiaphragmpump