SG-APSIC1045: A quantitative assessment of ATP bioluminescence on dental instruments reprocessed by automated washer-disinfector and ultrasonic machine

Objectives: Dental instruments are contaminated by blood and saliva during dental procedures. To prevent cross infection, all contaminants should be removed from the surfaces of instruments. Inadequate cleaning can hinder disinfection and sterilization process. To compare the cleaning efficacy of an...

Descripción completa

Detalles Bibliográficos
Autores principales: Man, Vivian, Neo, Tian Cheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cambridge University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10571110/
http://dx.doi.org/10.1017/ash.2023.96
_version_ 1785119911727595520
author Man, Vivian
Neo, Tian Cheng
author_facet Man, Vivian
Neo, Tian Cheng
author_sort Man, Vivian
collection PubMed
description Objectives: Dental instruments are contaminated by blood and saliva during dental procedures. To prevent cross infection, all contaminants should be removed from the surfaces of instruments. Inadequate cleaning can hinder disinfection and sterilization process. To compare the cleaning efficacy of an automated washer–disinfector versus an ultrasonic machine on dental instruments, adenosine triphosphate (ATP) measurements were compared. Methods: From National University Polyclinic Bukit Panjang Dental Services, we collected 2 loads of 40 dental instruments previously used in dental treatments: extraction forceps, high-volume suction tips, Coupland elevators, matrix band holders, and ultrasonic scaler tips. At the point of use, gross soil was wiped from instrument surfaces with water. Each instrument was swabbed after cleaning either using a washer–disinfector or an ultrasonic machine. The relative light units (RLU) on the luminometer indicated the amount of ATP contaminants and residue bioburden present on the instruments. Results: The mean RLU values across all instruments in the washer–disinfector group was 2.5 times lower than the mean value of the instruments in the ultrasonic group (35.4 vs 89.9 RLU). This difference was statistically significant for all instrument groups except for the high-volume suction tips. The Mann-Whitney U test indicated that the RLU in the ultrasonic group was higher than the RLU for the washer–disinfector group for extraction forceps (P < .001), ultrasonic scaler tips (P < .023), and matrix bands (P < .006). A t test indicated the same relationship for Coupland elevators (P < .005). Conclusions: The mean RLU values for both cleaning methods were lower than the manufacturer’s benchmark (RLU ≤ 150), suggesting that both methods can achieve effective cleaning. However, cleaning using an automated washer–disinfector is significantly more effective than an ultrasonic machine for nonlumen instruments. The effectiveness of cleaning using ultrasonic machine varied greatly among different types of instruments with different design complexities.
format Online
Article
Text
id pubmed-10571110
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cambridge University Press
record_format MEDLINE/PubMed
spelling pubmed-105711102023-10-14 SG-APSIC1045: A quantitative assessment of ATP bioluminescence on dental instruments reprocessed by automated washer-disinfector and ultrasonic machine Man, Vivian Neo, Tian Cheng Antimicrob Steward Healthc Epidemiol Sterilization and Disinfection Objectives: Dental instruments are contaminated by blood and saliva during dental procedures. To prevent cross infection, all contaminants should be removed from the surfaces of instruments. Inadequate cleaning can hinder disinfection and sterilization process. To compare the cleaning efficacy of an automated washer–disinfector versus an ultrasonic machine on dental instruments, adenosine triphosphate (ATP) measurements were compared. Methods: From National University Polyclinic Bukit Panjang Dental Services, we collected 2 loads of 40 dental instruments previously used in dental treatments: extraction forceps, high-volume suction tips, Coupland elevators, matrix band holders, and ultrasonic scaler tips. At the point of use, gross soil was wiped from instrument surfaces with water. Each instrument was swabbed after cleaning either using a washer–disinfector or an ultrasonic machine. The relative light units (RLU) on the luminometer indicated the amount of ATP contaminants and residue bioburden present on the instruments. Results: The mean RLU values across all instruments in the washer–disinfector group was 2.5 times lower than the mean value of the instruments in the ultrasonic group (35.4 vs 89.9 RLU). This difference was statistically significant for all instrument groups except for the high-volume suction tips. The Mann-Whitney U test indicated that the RLU in the ultrasonic group was higher than the RLU for the washer–disinfector group for extraction forceps (P < .001), ultrasonic scaler tips (P < .023), and matrix bands (P < .006). A t test indicated the same relationship for Coupland elevators (P < .005). Conclusions: The mean RLU values for both cleaning methods were lower than the manufacturer’s benchmark (RLU ≤ 150), suggesting that both methods can achieve effective cleaning. However, cleaning using an automated washer–disinfector is significantly more effective than an ultrasonic machine for nonlumen instruments. The effectiveness of cleaning using ultrasonic machine varied greatly among different types of instruments with different design complexities. Cambridge University Press 2023-03-16 /pmc/articles/PMC10571110/ http://dx.doi.org/10.1017/ash.2023.96 Text en © The Society for Healthcare Epidemiology of America 2023 https://creativecommons.org/licenses/by/4.0/This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Sterilization and Disinfection
Man, Vivian
Neo, Tian Cheng
SG-APSIC1045: A quantitative assessment of ATP bioluminescence on dental instruments reprocessed by automated washer-disinfector and ultrasonic machine
title SG-APSIC1045: A quantitative assessment of ATP bioluminescence on dental instruments reprocessed by automated washer-disinfector and ultrasonic machine
title_full SG-APSIC1045: A quantitative assessment of ATP bioluminescence on dental instruments reprocessed by automated washer-disinfector and ultrasonic machine
title_fullStr SG-APSIC1045: A quantitative assessment of ATP bioluminescence on dental instruments reprocessed by automated washer-disinfector and ultrasonic machine
title_full_unstemmed SG-APSIC1045: A quantitative assessment of ATP bioluminescence on dental instruments reprocessed by automated washer-disinfector and ultrasonic machine
title_short SG-APSIC1045: A quantitative assessment of ATP bioluminescence on dental instruments reprocessed by automated washer-disinfector and ultrasonic machine
title_sort sg-apsic1045: a quantitative assessment of atp bioluminescence on dental instruments reprocessed by automated washer-disinfector and ultrasonic machine
topic Sterilization and Disinfection
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10571110/
http://dx.doi.org/10.1017/ash.2023.96
work_keys_str_mv AT manvivian sgapsic1045aquantitativeassessmentofatpbioluminescenceondentalinstrumentsreprocessedbyautomatedwasherdisinfectorandultrasonicmachine
AT neotiancheng sgapsic1045aquantitativeassessmentofatpbioluminescenceondentalinstrumentsreprocessedbyautomatedwasherdisinfectorandultrasonicmachine