Cargando…

SG-APSIC1024: The importance of the washing evaluation of flusher disinfector in the medical site: Visual evaluation with the ISO standardized test soil and adenosine triphosphate level

Objectives: We examined the washing evaluation method of the flusher disinfector installed in the medical site by visual evaluation using an ISO test soil and adenosine triphosphate (ATP) measurement. Methods: The test soil shown in ISO15883-5 was applied to the bedpan using 2 methods (N = 10) and w...

Descripción completa

Detalles Bibliográficos
Autores principales: Shima, Mari, Yoshida, Rika, Okubo, Takashi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cambridge University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10571205/
http://dx.doi.org/10.1017/ash.2023.103
_version_ 1785119935887835136
author Shima, Mari
Yoshida, Rika
Okubo, Takashi
author_facet Shima, Mari
Yoshida, Rika
Okubo, Takashi
author_sort Shima, Mari
collection PubMed
description Objectives: We examined the washing evaluation method of the flusher disinfector installed in the medical site by visual evaluation using an ISO test soil and adenosine triphosphate (ATP) measurement. Methods: The test soil shown in ISO15883-5 was applied to the bedpan using 2 methods (N = 10) and was then visually evaluated using a 4-step scale. The ATP value on the surface of the bedpan corresponding to each scale was measured, and the correlation with the visual scale was confirmed. In addition, a visual evaluation was performed using a different flusher disinfector and bedpan (N = 3). Results: In the visual evaluation, when the test soil was applied to the entire surface of the bedpan, it remained in the parts where the water flow was hard to hit. When the test soil was applied to the surface of the bedpan except the lid, no soil remained. The 4-step visual evaluation scale and the logarithm of ATP value showed a positive correlation. In visual evaluations with different flusher disinfector and bedpan combinations, the residual soil patterns tended to be different. Some bedpans showed washing failure related to improper design. Conclusions: Poor cleaning of flusher disinfectors may occur when the amount of water used is insufficient or when the bedpan is significantly contaminated. It is important to carry out flusher disinfector washing evaluation at medical sites to evaluate the function of flusher disinfectors. An appropriate program must be utilized for staff education and appropriate management. Because flusher disinfectors and bedpans differ, flusher disinfector cleaning evaluations should be carried out at all facilities.
format Online
Article
Text
id pubmed-10571205
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cambridge University Press
record_format MEDLINE/PubMed
spelling pubmed-105712052023-10-14 SG-APSIC1024: The importance of the washing evaluation of flusher disinfector in the medical site: Visual evaluation with the ISO standardized test soil and adenosine triphosphate level Shima, Mari Yoshida, Rika Okubo, Takashi Antimicrob Steward Healthc Epidemiol Sterilization and Disinfection Objectives: We examined the washing evaluation method of the flusher disinfector installed in the medical site by visual evaluation using an ISO test soil and adenosine triphosphate (ATP) measurement. Methods: The test soil shown in ISO15883-5 was applied to the bedpan using 2 methods (N = 10) and was then visually evaluated using a 4-step scale. The ATP value on the surface of the bedpan corresponding to each scale was measured, and the correlation with the visual scale was confirmed. In addition, a visual evaluation was performed using a different flusher disinfector and bedpan (N = 3). Results: In the visual evaluation, when the test soil was applied to the entire surface of the bedpan, it remained in the parts where the water flow was hard to hit. When the test soil was applied to the surface of the bedpan except the lid, no soil remained. The 4-step visual evaluation scale and the logarithm of ATP value showed a positive correlation. In visual evaluations with different flusher disinfector and bedpan combinations, the residual soil patterns tended to be different. Some bedpans showed washing failure related to improper design. Conclusions: Poor cleaning of flusher disinfectors may occur when the amount of water used is insufficient or when the bedpan is significantly contaminated. It is important to carry out flusher disinfector washing evaluation at medical sites to evaluate the function of flusher disinfectors. An appropriate program must be utilized for staff education and appropriate management. Because flusher disinfectors and bedpans differ, flusher disinfector cleaning evaluations should be carried out at all facilities. Cambridge University Press 2023-03-16 /pmc/articles/PMC10571205/ http://dx.doi.org/10.1017/ash.2023.103 Text en © The Society for Healthcare Epidemiology of America 2023 https://creativecommons.org/licenses/by/4.0/This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Sterilization and Disinfection
Shima, Mari
Yoshida, Rika
Okubo, Takashi
SG-APSIC1024: The importance of the washing evaluation of flusher disinfector in the medical site: Visual evaluation with the ISO standardized test soil and adenosine triphosphate level
title SG-APSIC1024: The importance of the washing evaluation of flusher disinfector in the medical site: Visual evaluation with the ISO standardized test soil and adenosine triphosphate level
title_full SG-APSIC1024: The importance of the washing evaluation of flusher disinfector in the medical site: Visual evaluation with the ISO standardized test soil and adenosine triphosphate level
title_fullStr SG-APSIC1024: The importance of the washing evaluation of flusher disinfector in the medical site: Visual evaluation with the ISO standardized test soil and adenosine triphosphate level
title_full_unstemmed SG-APSIC1024: The importance of the washing evaluation of flusher disinfector in the medical site: Visual evaluation with the ISO standardized test soil and adenosine triphosphate level
title_short SG-APSIC1024: The importance of the washing evaluation of flusher disinfector in the medical site: Visual evaluation with the ISO standardized test soil and adenosine triphosphate level
title_sort sg-apsic1024: the importance of the washing evaluation of flusher disinfector in the medical site: visual evaluation with the iso standardized test soil and adenosine triphosphate level
topic Sterilization and Disinfection
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10571205/
http://dx.doi.org/10.1017/ash.2023.103
work_keys_str_mv AT shimamari sgapsic1024theimportanceofthewashingevaluationofflusherdisinfectorinthemedicalsitevisualevaluationwiththeisostandardizedtestsoilandadenosinetriphosphatelevel
AT yoshidarika sgapsic1024theimportanceofthewashingevaluationofflusherdisinfectorinthemedicalsitevisualevaluationwiththeisostandardizedtestsoilandadenosinetriphosphatelevel
AT okubotakashi sgapsic1024theimportanceofthewashingevaluationofflusherdisinfectorinthemedicalsitevisualevaluationwiththeisostandardizedtestsoilandadenosinetriphosphatelevel