SG-APSIC1206: Effectiveness of sterilization practice in reprocessing medical devices among different multidisciplinary tertiary-care hospitals in Dhaka City

Objectives: Sterilization failure is one of the main causes of surgical-site infections. We assessed the effectiveness of the sterilization process of surgical instruments to determine the reasons for sterilization failure. Methods: In total, 100 sterilization cycles were observed from February 4, 2...

Descripción completa

Detalles Bibliográficos
Autores principales: Zaman, Sifat Uz, Adnan, Nihad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cambridge University Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10571213/
http://dx.doi.org/10.1017/ash.2023.97
_version_ 1785119937792049152
author Zaman, Sifat Uz
Adnan, Nihad
author_facet Zaman, Sifat Uz
Adnan, Nihad
author_sort Zaman, Sifat Uz
collection PubMed
description Objectives: Sterilization failure is one of the main causes of surgical-site infections. We assessed the effectiveness of the sterilization process of surgical instruments to determine the reasons for sterilization failure. Methods: In total, 100 sterilization cycles were observed from February 4, 2022, to September 5, 2022, in hospitals in Dhaka City. We used sterilization quality assurance monitoring tools (ie, biological indicators) for rapid steam and ethylene oxide sterilization methods. Tests were performed using an automatic reading machine, chemical indicator strips, and indicator tape for both steam and ethylene oxide methods. For laboratory testing and data collection, APSIC guidelines were followed. All samples were incubated for 48 hours to cross check the accuracy of the auto-reader result. Results: All ethylene oxide sterilization cycles were 100% successful, as shown by the rapid biological indicator (auto-reader), chemical indicator strips, and indicator tape. However, 22% sterilization failure occurred with steam sterilization, which was confirmed by the auto-reader, chemical indicator strips, and indicator tape. All biological samples showed no growth after 48 hours of incubation, except the sample from steam sterilization, which did show growth after 48 hours of incubation. Conclusions: We detected 22% steam sterilization failure, and serious harm to patients could occur if these surgical instruments were used for surgery. Process recall would not have been not possible if rapid biological indicator tests had not been performed and other chemical monitoring tools had not been used. The regular use of monitoring tools according to guidelines can be a reliable solution to reduce surgical site infections caused by inappropriate sterilization of surgical instruments.
format Online
Article
Text
id pubmed-10571213
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cambridge University Press
record_format MEDLINE/PubMed
spelling pubmed-105712132023-10-14 SG-APSIC1206: Effectiveness of sterilization practice in reprocessing medical devices among different multidisciplinary tertiary-care hospitals in Dhaka City Zaman, Sifat Uz Adnan, Nihad Antimicrob Steward Healthc Epidemiol Sterilization and Disinfection Objectives: Sterilization failure is one of the main causes of surgical-site infections. We assessed the effectiveness of the sterilization process of surgical instruments to determine the reasons for sterilization failure. Methods: In total, 100 sterilization cycles were observed from February 4, 2022, to September 5, 2022, in hospitals in Dhaka City. We used sterilization quality assurance monitoring tools (ie, biological indicators) for rapid steam and ethylene oxide sterilization methods. Tests were performed using an automatic reading machine, chemical indicator strips, and indicator tape for both steam and ethylene oxide methods. For laboratory testing and data collection, APSIC guidelines were followed. All samples were incubated for 48 hours to cross check the accuracy of the auto-reader result. Results: All ethylene oxide sterilization cycles were 100% successful, as shown by the rapid biological indicator (auto-reader), chemical indicator strips, and indicator tape. However, 22% sterilization failure occurred with steam sterilization, which was confirmed by the auto-reader, chemical indicator strips, and indicator tape. All biological samples showed no growth after 48 hours of incubation, except the sample from steam sterilization, which did show growth after 48 hours of incubation. Conclusions: We detected 22% steam sterilization failure, and serious harm to patients could occur if these surgical instruments were used for surgery. Process recall would not have been not possible if rapid biological indicator tests had not been performed and other chemical monitoring tools had not been used. The regular use of monitoring tools according to guidelines can be a reliable solution to reduce surgical site infections caused by inappropriate sterilization of surgical instruments. Cambridge University Press 2023-03-16 /pmc/articles/PMC10571213/ http://dx.doi.org/10.1017/ash.2023.97 Text en © The Society for Healthcare Epidemiology of America 2023 https://creativecommons.org/licenses/by/4.0/This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Sterilization and Disinfection
Zaman, Sifat Uz
Adnan, Nihad
SG-APSIC1206: Effectiveness of sterilization practice in reprocessing medical devices among different multidisciplinary tertiary-care hospitals in Dhaka City
title SG-APSIC1206: Effectiveness of sterilization practice in reprocessing medical devices among different multidisciplinary tertiary-care hospitals in Dhaka City
title_full SG-APSIC1206: Effectiveness of sterilization practice in reprocessing medical devices among different multidisciplinary tertiary-care hospitals in Dhaka City
title_fullStr SG-APSIC1206: Effectiveness of sterilization practice in reprocessing medical devices among different multidisciplinary tertiary-care hospitals in Dhaka City
title_full_unstemmed SG-APSIC1206: Effectiveness of sterilization practice in reprocessing medical devices among different multidisciplinary tertiary-care hospitals in Dhaka City
title_short SG-APSIC1206: Effectiveness of sterilization practice in reprocessing medical devices among different multidisciplinary tertiary-care hospitals in Dhaka City
title_sort sg-apsic1206: effectiveness of sterilization practice in reprocessing medical devices among different multidisciplinary tertiary-care hospitals in dhaka city
topic Sterilization and Disinfection
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10571213/
http://dx.doi.org/10.1017/ash.2023.97
work_keys_str_mv AT zamansifatuz sgapsic1206effectivenessofsterilizationpracticeinreprocessingmedicaldevicesamongdifferentmultidisciplinarytertiarycarehospitalsindhakacity
AT adnannihad sgapsic1206effectivenessofsterilizationpracticeinreprocessingmedicaldevicesamongdifferentmultidisciplinarytertiarycarehospitalsindhakacity