SG-APSIC1206: Effectiveness of sterilization practice in reprocessing medical devices among different multidisciplinary tertiary-care hospitals in Dhaka City
Objectives: Sterilization failure is one of the main causes of surgical-site infections. We assessed the effectiveness of the sterilization process of surgical instruments to determine the reasons for sterilization failure. Methods: In total, 100 sterilization cycles were observed from February 4, 2...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cambridge University Press
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10571213/ http://dx.doi.org/10.1017/ash.2023.97 |
_version_ | 1785119937792049152 |
---|---|
author | Zaman, Sifat Uz Adnan, Nihad |
author_facet | Zaman, Sifat Uz Adnan, Nihad |
author_sort | Zaman, Sifat Uz |
collection | PubMed |
description | Objectives: Sterilization failure is one of the main causes of surgical-site infections. We assessed the effectiveness of the sterilization process of surgical instruments to determine the reasons for sterilization failure. Methods: In total, 100 sterilization cycles were observed from February 4, 2022, to September 5, 2022, in hospitals in Dhaka City. We used sterilization quality assurance monitoring tools (ie, biological indicators) for rapid steam and ethylene oxide sterilization methods. Tests were performed using an automatic reading machine, chemical indicator strips, and indicator tape for both steam and ethylene oxide methods. For laboratory testing and data collection, APSIC guidelines were followed. All samples were incubated for 48 hours to cross check the accuracy of the auto-reader result. Results: All ethylene oxide sterilization cycles were 100% successful, as shown by the rapid biological indicator (auto-reader), chemical indicator strips, and indicator tape. However, 22% sterilization failure occurred with steam sterilization, which was confirmed by the auto-reader, chemical indicator strips, and indicator tape. All biological samples showed no growth after 48 hours of incubation, except the sample from steam sterilization, which did show growth after 48 hours of incubation. Conclusions: We detected 22% steam sterilization failure, and serious harm to patients could occur if these surgical instruments were used for surgery. Process recall would not have been not possible if rapid biological indicator tests had not been performed and other chemical monitoring tools had not been used. The regular use of monitoring tools according to guidelines can be a reliable solution to reduce surgical site infections caused by inappropriate sterilization of surgical instruments. |
format | Online Article Text |
id | pubmed-10571213 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Cambridge University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-105712132023-10-14 SG-APSIC1206: Effectiveness of sterilization practice in reprocessing medical devices among different multidisciplinary tertiary-care hospitals in Dhaka City Zaman, Sifat Uz Adnan, Nihad Antimicrob Steward Healthc Epidemiol Sterilization and Disinfection Objectives: Sterilization failure is one of the main causes of surgical-site infections. We assessed the effectiveness of the sterilization process of surgical instruments to determine the reasons for sterilization failure. Methods: In total, 100 sterilization cycles were observed from February 4, 2022, to September 5, 2022, in hospitals in Dhaka City. We used sterilization quality assurance monitoring tools (ie, biological indicators) for rapid steam and ethylene oxide sterilization methods. Tests were performed using an automatic reading machine, chemical indicator strips, and indicator tape for both steam and ethylene oxide methods. For laboratory testing and data collection, APSIC guidelines were followed. All samples were incubated for 48 hours to cross check the accuracy of the auto-reader result. Results: All ethylene oxide sterilization cycles were 100% successful, as shown by the rapid biological indicator (auto-reader), chemical indicator strips, and indicator tape. However, 22% sterilization failure occurred with steam sterilization, which was confirmed by the auto-reader, chemical indicator strips, and indicator tape. All biological samples showed no growth after 48 hours of incubation, except the sample from steam sterilization, which did show growth after 48 hours of incubation. Conclusions: We detected 22% steam sterilization failure, and serious harm to patients could occur if these surgical instruments were used for surgery. Process recall would not have been not possible if rapid biological indicator tests had not been performed and other chemical monitoring tools had not been used. The regular use of monitoring tools according to guidelines can be a reliable solution to reduce surgical site infections caused by inappropriate sterilization of surgical instruments. Cambridge University Press 2023-03-16 /pmc/articles/PMC10571213/ http://dx.doi.org/10.1017/ash.2023.97 Text en © The Society for Healthcare Epidemiology of America 2023 https://creativecommons.org/licenses/by/4.0/This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Sterilization and Disinfection Zaman, Sifat Uz Adnan, Nihad SG-APSIC1206: Effectiveness of sterilization practice in reprocessing medical devices among different multidisciplinary tertiary-care hospitals in Dhaka City |
title | SG-APSIC1206: Effectiveness of sterilization practice in reprocessing medical devices among different multidisciplinary tertiary-care hospitals in Dhaka City |
title_full | SG-APSIC1206: Effectiveness of sterilization practice in reprocessing medical devices among different multidisciplinary tertiary-care hospitals in Dhaka City |
title_fullStr | SG-APSIC1206: Effectiveness of sterilization practice in reprocessing medical devices among different multidisciplinary tertiary-care hospitals in Dhaka City |
title_full_unstemmed | SG-APSIC1206: Effectiveness of sterilization practice in reprocessing medical devices among different multidisciplinary tertiary-care hospitals in Dhaka City |
title_short | SG-APSIC1206: Effectiveness of sterilization practice in reprocessing medical devices among different multidisciplinary tertiary-care hospitals in Dhaka City |
title_sort | sg-apsic1206: effectiveness of sterilization practice in reprocessing medical devices among different multidisciplinary tertiary-care hospitals in dhaka city |
topic | Sterilization and Disinfection |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10571213/ http://dx.doi.org/10.1017/ash.2023.97 |
work_keys_str_mv | AT zamansifatuz sgapsic1206effectivenessofsterilizationpracticeinreprocessingmedicaldevicesamongdifferentmultidisciplinarytertiarycarehospitalsindhakacity AT adnannihad sgapsic1206effectivenessofsterilizationpracticeinreprocessingmedicaldevicesamongdifferentmultidisciplinarytertiarycarehospitalsindhakacity |