Cargando…
Reliability of point-of-care ultrasound to evaluate fluid tolerance performed by critical care residents
BACKGROUND: Patients with hypotension usually receive intravenous fluids, but only 50% will respond to fluid administration. We aimed to assess the intra and interobserver agreement to evaluate fluid tolerance through diverse ultrasonographic methods. METHODS: We prospectively included critically il...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10571403/ https://www.ncbi.nlm.nih.gov/pubmed/37828607 http://dx.doi.org/10.1186/s40001-023-01397-9 |
Sumario: | BACKGROUND: Patients with hypotension usually receive intravenous fluids, but only 50% will respond to fluid administration. We aimed to assess the intra and interobserver agreement to evaluate fluid tolerance through diverse ultrasonographic methods. METHODS: We prospectively included critically ill patients on mechanical ventilation. One trained intensivist and two intensive care residents obtained the left ventricular outflow tract velocity–time integral (VTI) variability, inferior vena cava (IVC) distensibility index, internal jugular vein (IJV) distensibility index, and each component of the venous excess ultrasound (VExUS) system. We obtained the intraclass correlation coefficient (ICC) and Gwet’s first-order agreement coefficient (AC1), as appropriate. RESULTS: We included 32 patients. In-training observers were unable to assess the VTI-variability in two patients. The interobserver agreement was moderate to evaluate the IJV-distensibility index (AC1 0.54, CI 95% 0.29–0.80), fair to evaluate VTI-variability (AC1 0.39, CI 95% 0.12–0.66), and absent to evaluate the IVC-distensibility index (AC1 0.19, CI 95% − 0.07 to 0.44). To classify patients according to their VExUS grade, the intraobserver agreement was good, and the interobserver agreement was moderate (AC1 0.52, CI 95% 0.34–0.69). CONCLUSIONS: Point-of-care ultrasound is frequently used to support decision-making in fluid management. However, we observed that the VTI variability and IVC-distensibility index might require further training of the ultrasound operators to be clinically useful. Our findings suggest that the IJV-distensibility index and the VExUS system have acceptable reproducibility among in-training observers. |
---|